Elmo Rietschle 2BH7530
Elmo Rietschle 2BH7530 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -590 mbar, Motor power 7.5 kW, Noise level 79 dB.
The 2BH7530 is a side-channel blower with an integrated frequency converter (VFD type 2FC4752-1□□00), configured for 345 V / 87 Hz delta operation from a 380–480 V mains. It delivers up to 760 mbar differential pressure at 7.5 kW, distinguishing it from smaller G-BH7 siblings by its higher pressure capability and built-in variable-speed drive. It is intended for pressure or vacuum duty in process systems where speed control and compact integration are required.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH7530 Current | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | -590 mbar (100 Hz) 87 Hz: -610 mbar · 60 Hz: -690 mbar · 50 Hz: -680 mbar |
| Motor power | 8.8 kW (100 Hz) 87 Hz: 7.5 kW |
| Noise level | 79 dB(A) (100 Hz) 87 Hz: 79 dB(A) · 60 Hz: 70 dB(A) · 50 Hz: 66 dB(A) |
| Motor connection mfr | delta |
| Order No. mfr | 2BH7530-0AK76-1 |
| Max. differential pressure (vacuum) mfr | -530 mbar (37 Hz) |
| Max. differential pressure (vacuum) mfr | -680 mbar (50 Hz) |
| Max. differential pressure (vacuum) mfr | -690 mbar (60 Hz) |
| Max. differential pressure (vacuum) mfr | -610 mbar (87 Hz) |
| Max. differential pressure (alt 100 Hz) mfr | 600 mbar (100 Hz) |
| Max. differential pressure (alt 87 Hz) mfr | 760 mbar (87 Hz) |
| Max. differential pressure (alt 60 Hz) mfr | 900 mbar (60 Hz) |
| Max. differential pressure (alt 50 Hz) mfr | 950 mbar (50 Hz) |
| Weight | 80 kg |
| Weight approx. mfr | 50 kg |
| Current | 16.2 A (100 Hz (U connection)) 87 Hz (delta connection): 14.4 A |
| Frequency | 100 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 400 V (100 Hz (U connection)) 87 Hz (delta connection): 400 V |
| Rated voltage/frequency set point mfr | 345 V / 87 Hz V / Hz |
| Frequency converter pulse frequency mfr | 4 kHz |
| Mains voltage minimum mfr | 380 V |
| Rated motor voltage mfr | 400 V |
| Max. motor current mfr | 8,8 A |
| VFD rated mains voltage mfr | 400V (-15%) ... 480V (+10%) V |
| VFD rated mains current mfr | 7,5 A |
| VFD typical motor power mfr | 7,5 kW |
| VFD max. motor current mfr | 14,8 A |
| Rated motor current mfr | 16,2 A |
| Rated motor voltage mfr | 400 V (87 Hz) |
| Rated motor current mfr | 14,4 A (87 Hz) |
| Rated voltage frequency set point mfr | 345 V (87 Hz) |
| Mains voltage mfr | 380 V (minimum) |
| Frequency (alt var) mfr | 50 Hz |
| Protection rating | IP55 |
| Sound pressure level mfr | 79 dB(A) |
| Sound pressure level mfr | 72/74 dB(A) (50 Hz / 60 Hz) |
| Sound pressure level mfr | 72 dB(A) (G17) |
| Sound pressure level (with G17) mfr | 72/74 dB(A) (50 Hz / 60 Hz) |
| Sound pressure level (with G17) mfr | 74 dB(A) |
| Sound pressure level mfr | 67 dB(A) (37 Hz) |
| Sound pressure level mfr | 66 dB(A) (50 Hz) |
| Sound pressure level mfr | 70 dB(A) (60 Hz) |
| Sound pressure level mfr | 79 dB(A) (87 Hz) |
Description
Construction and series positioning
- Single-stage side-channel (regenerative) blower with close-coupled 7.5 kW motor and integrated VFD; protection class IP55, insulation class F.
- Within the G-BH7 series, the 2BH7530 is the larger frame relative to the 2BH721/2BH722 and 2BH7210/2BH7220 siblings, offering higher maximum differential pressure (760 mbar) and motor power.
- The integrated VFD (2FC4752-1□□00, 7.5 kW typical motor power, 14.8 A max motor current) replaces a separate cabinet-mounted drive, simplifying wiring and footprint.
Behavior under load and media
- Maximum differential pressure is 760 mbar; the machine is designed for continuous duty in air or neutral gases within the limits of the side-channel principle.
- Motor is rated 400 V D (delta) at 87 Hz, 14.4 A; the VFD output current must be limited to 8.8 A to protect the motor. The VFD pulse frequency is 4 kHz.
- Sound pressure level is 66 dB(A) at 50 Hz, 70 dB(A) at 60 Hz, 79 dB(A) at 87 Hz, and 79 dB(A) at 100 Hz.
- No digitized curve points are available in the supplied facts; performance at intermediate speeds must be obtained from the manufacturer’s selection software or additional documentation.
Installation, connection and control
- The integrated VFD accepts a 3-phase mains of 400 V (−15%) to 480 V (+10%), 50/60 Hz; rated mains current is 7.5 A.
- Motor connection is delta; the factory set point is 345 V / 87 Hz, which must be respected when commissioning to avoid over-fluxing or overload.
- The VFD type 2FC4752-1□□00 provides local control and monitoring; refer to the VFD manual for I/O assignment, parameterization and fault codes.
- Weight is approximately 50 kg; ensure mounting surface and lifting equipment are rated accordingly.
Integration & Operating Notes
The motor’s maximum current is 8.8 A, while the VFD can deliver up to 14.8 A. The drive must be parameterized with a motor current limit of 8.8 A to prevent winding overheating and insulation degradation, especially at low speeds where cooling is reduced.
The integrated VFD is rated for this window. Operation outside it may cause undervoltage or overvoltage trips, and the 345 V / 87 Hz set point assumes a nominal 400 V supply. A step-up or step-down transformer may be required for other mains.
The VFD must be set for delta connection, 87 Hz base frequency, 345 V rated voltage and 8.8 A current limit. Starting without these settings risks overload trips or motor damage. Use the VFD manual for the parameter list and startup procedure.
Exceeding 760 mbar may cause motor overload, excessive temperature rise or mechanical damage. Install a pressure relief valve or monitor differential pressure and interlock the drive to trip if the limit is approached.
Dust buildup on the impeller and inlet filter reduces performance and can cause imbalance. The service interval depends on the process air cleanliness; check at least every 2000 hours or more frequently in dusty environments. Refer to the operating manual for detailed procedures.
Selection & Integration Q&A
Choose the 2BH7530 when your process requires up to 760 mbar differential pressure and 7.5 kW motor power. The smaller siblings offer lower pressure and power; select them only if your duty point falls within their lower limits. The integrated VFD on the 2BH7530 also provides speed control without a separate cabinet drive.
The VFD requires a 3-phase supply of 400 V (−15%) to 480 V (+10%), 50/60 Hz, with a rated mains current of 7.5 A. Provide a circuit breaker or fuses sized to the VFD’s input current and consider a line reactor if the supply is prone to transients.
The base delivery includes the blower with integrated VFD but typically excludes inlet/outlet silencers, filters, flexible connectors, and a pressure relief valve. These must be ordered separately. Maintenance kits such as impeller seals and bearings are available as spare parts; refer to the spare parts list for part numbers.