Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — L-BV5 2BV5110 IE3 compressor (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BV5 110, liquid ring compressor of the L-BV5 range; covers 50 Hz and 60 Hz voltage variants, cast iron (K) and CrNi steel (H) material versions, IE3 and NP motor efficiency variants, and ATEX category 2G availability.

Technical Data

Parameter Value Condition
Rated voltage 190-210 V p.2 ↗ 2BV5 110, 50 Hz, delta
Rated voltage 380-420 V p.2 ↗ 2BV5 110, 50 Hz, star
Rated current 22,4 A p.2 ↗ 2BV5 110, 50 Hz, 190-210 V delta
Rated current 12,7 A p.2 ↗ 2BV5 110, 50 Hz, 380-420 V star
Motor power 5,5 kW p.2 ↗ 2BV5 110, 50 Hz
Service factor 1,00 p.2 ↗ 2BV5 110, 50 Hz
Efficiency class IE3 p.2 ↗ 2BV5 110, 50 Hz, IE3 variant
Efficiency class NP p.2 ↗ 2BV5 110, 50 Hz, NP variant
Operating liquid level 1,00 p.2 ↗ 2BV5 110, 50 Hz
Suction capacity 61 m³/h p.2 ↗ 2BV5 110, 50 Hz, IE3
Suction capacity 67 m³/h p.2 ↗ 2BV5 110, 50 Hz, NP
Noise level 61 dB(A) p.2 ↗ 2BV5 110, 50 Hz, IE3
Noise level 67 dB(A) p.2 ↗ 2BV5 110, 50 Hz, NP
Weight 110 kg p.2 ↗ 2BV5 110, cast iron version K
Weight 112 kg p.2 ↗ 2BV5 110, CrNi steel version H
Rated voltage 220-240 V p.2 ↗ 2BV5 110, 50 Hz, delta
Rated voltage 440-480 V p.2 ↗ 2BV5 110, 50 Hz, star
Rated current 21,5 A p.2 ↗ 2BV5 110, 50 Hz, 220-240 V delta
Rated current 10,8 A p.2 ↗ 2BV5 110, 50 Hz, 440-480 V star
Rated voltage 500 V p.2 ↗ 2BV5 110, 50 Hz, star
Rated current 8,6 A p.2 ↗ 2BV5 110, 50 Hz, 500 V star
Rated voltage 575 V p.2 ↗ 2BV5 110, 60 Hz, star
Rated current 8,3 A p.2 ↗ 2BV5 110, 60 Hz, 575 V star
Protection rating IP55 p.1 ↗ standard motors
Voltage tolerance +/-10 % p.2 ↗ three phase motors

Operating Limits

  • Protection rating: IP55 p.1 ↗
  • Voltage tolerance: +/-10 % p.2 ↗
  • Frequency tolerance: +/- 2 % maximum p.2 ↗
  • Thermal class: F p.2 ↗
  • ATEX category: 2G p.1 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BV5110 Type designation: liquid ring compressor, model range L-BV5, size 110
10-13 p.2 ↗ K02- Order code block; K = cast iron version, 02 = variant code
voltage field p.2 ↗ 475-525 V Y / 550-600 V Y / 400 V delta / 690 V Y / 460 V delta Available voltage connection variants for 50 Hz and 60 Hz