Elmo Rietschle 2BV5110
Elmo Rietschle 2BV5110 — Liquid Ring Vacuum Pumps with Motor power 5.5 kW.
The 2BV5110 is a monoblock liquid ring vacuum pump/compressor from the L-BV5 series, driven by a 5.5 kW IE3 motor for 50/60 Hz operation. It is the base 5.5 kW modification in the series, positioned below the 7.5 kW 2BV5111 and above smaller L-BV2 types, and is intended for continuous vacuum generation where a compact, close-coupled unit with IP55 protection is required.
Elmo Rietschle L-BV5 Series — Model Comparison & Selection
| Model | Motor power, kW | Operating principle | Noise level, dB | Power supply | Pumping speed, m³/h | Weight, kg |
|---|---|---|---|---|---|---|
| 2BV5110 Current | 5.5 | ring blow | 67 | AC | — | 67 |
| 2BV5111 | 7.5 | Liquid ring | 72 | 3~ AC | — | 124 |
| 2BV5121 | 11 | Liquid ring compressor | 70 | AC | 40 | — |
| 2BV5131 | 15 | Liquid ring | 74 | AC | 17.4 | 178 |
| 2BV5161 | 15 | Liquid ring | 74 | AC | 500 | 160 |
| L-BV5 2060 | — | — | — | — | — | — |
Full specifications
| Motor power | 5.5 kW (50 Hz) 60 Hz: 5.5 kW |
| Operating principle | ring blow |
| Design (alt var) mfr | monoblock |
| Weight | 67 kg |
| Power supply | AC (3~ 50/60 Hz) |
| Noise level | 67 dB(A) |
| Protection rating | IP55 |
| Sound pressure level (alt var) mfr | 61 dB(A) |
Description
Construction and series positioning
- Monoblock design: the impeller is directly mounted on the motor shaft, eliminating separate bearing brackets and couplings.
- Casing materials: cast iron with ceramic internal coating (K) or CrNi steel (H); stainless steel construction is available for the 2BV51.. range.
- Within the L-BV5 series, the 2BV5110 is the lowest-power 5.5 kW variant; the 2BV5111 offers 7.5 kW, the 2BV5121 11.0 kW, and the 2BV5131/2BV5161 15.0 kW. The 2BV5110 is therefore selected when the duty point falls within its hydraulic range and a smaller motor frame is sufficient.
- The pump operates on the liquid ring principle: an operating liquid (typically water) forms a rotating ring that creates vacuum or slight overpressure. The 2BV5110 is configured for vacuum pump duty; compressor duty is covered by other series members.
Behavior under load and media
- Maximum gas/vapour temperature at inlet: +80 °C. For higher temperatures, the operating-liquid flow must be increased to 2× the design flow (for 2BV5..) or a pre-condenser must be installed.
- Operating-liquid temperature range: +5 °C to +80 °C, nominal +15 °C. Ambient temperature range: +5 °C to +40 °C.
- Maximum discharge pressure in vacuum operation: 1.3 bar abs for 2BV5.. types. Maximum permissible internal pressure: 8 bar abs (6 bar abs for 2BV5410-.F).
- Maximum water carry-over through the inlet: 2.5× the design operating-liquid flow continuous, 5× for max 2 s (2BV51..).
- First fill quantity of operating liquid for 2BV5110: 3.0 L.
- Maximum speed with frequency converter: 1402–2454 min⁻¹ for 2BV5110/5111 (covers both 50 Hz and 60 Hz operation).
Installation, connection and operation
- Installation must ensure vibration velocity veff ≤ 4.5 mm/s measured at the points shown in Fig. 7. Maximum installation altitude: 1000 m above sea level; consult service if higher.
- Piping connections to suction and discharge must not be over-tightened: maximum tightening torque 100 Nm.
- An intake strainer should be fitted in the suction line for the first 100 operating hours to prevent installation residues from entering the unit.
- Electrical supply tolerance: ±5% voltage and ±2% frequency deviation without loss of performance. Minimum air gap between non-insulated energized components and earth: 5.5 mm at rated voltage U_N ≤ 690 V.
- Motor insulation resistance must be checked before commissioning; dry windings if ≤1 kΩ per volt of measurement potential.
- Minimum clearance for heat dissipation around the fan guard: 53 mm for 2BV5110.
- Operation with frequency converter is permitted within the speed range above; for ATEX versions, frequency converter operation is not permitted.
- The pump must not run dry; ensure operating-liquid supply is established before start-up and check direction of rotation.
Integration & Operating Notes
The maximum permissible vibration velocity is 4.5 mm/s. Measure at the points shown in Fig. 7 after installation. Exceeding this limit indicates misalignment, pipe strain, or foundation issues that can lead to premature bearing failure and seal damage.
In vacuum operation, the maximum discharge pressure is 1.3 bar abs for 2BV5.. types. Ensure the system downstream cannot impose higher pressure; install appropriate protection if higher pressures can occur. The maximum permissible internal pressure is 8 bar abs.
Measure insulation resistance before commissioning. If the value is ≤1 kΩ per volt of measurement potential, the windings must be dried. Starting with low insulation resistance can cause motor failure or earth faults.
When driven by a frequency converter, the speed must stay within 1402–2454 min⁻¹ for the 2BV5110 (covers both 50 Hz and 60 Hz operation). Exceeding this range can cause cavitation, vibration, or motor overload. For ATEX versions, frequency converter operation is not permitted at all.
Bearing maintenance is due every 2.5 years or 20,000 operating hours, whichever comes first. Use UNIREX N3 grease (or DIN 51825-K3N equivalent) and fill approximately 50% of the free space in roller bearings and 65% of adjacent areas. Do not mix grease types.
To prevent installation residues (weld slag, scale, debris) from entering the pump and damaging the impeller or casing, install a temporary intake strainer in the suction line. Remove or clean it after the first 100 operating hours.
The operating liquid temperature must be maintained between +5 °C and +80 °C, with a nominal value of +15 °C. Temperatures outside this range affect vacuum performance and can cause cavitation or seal damage. Ensure the liquid supply system can maintain this temperature.
Selection & Integration Q&A
Choose the 2BV5110 when your required vacuum level and pumping speed are met by its 5.5 kW motor, which is the lowest power in the L-BV5 series. The 2BV5111 offers 7.5 kW for higher capacity, and the 2BV5121 11.0 kW for even greater flow. Select the smallest motor that covers the duty point to minimize energy use and frame size.
Piping must be supported independently and connected without strain. Tightening torque for the suction and discharge connections must not exceed 100 Nm. Install an intake strainer for the first 100 operating hours. Ensure the discharge line cannot impose more than 1.3 bar abs during vacuum operation.
Ambient temperature must stay between +5 °C and +40 °C. Maximum installation altitude is 1000 m above sea level; consult the manufacturer if higher. Maintain a minimum clearance of 53 mm around the fan guard for heat dissipation. Vibration velocity at the installation must not exceed 4.5 mm/s.
The base delivery does not include the operating liquid, suction strainer, or monitoring devices. You must provide an operating-liquid supply system with flow control; the first fill quantity for the 2BV5110 is 3.0 L. For ATEX installations, mandatory monitoring includes liquid level, flow, and discharge pressure switches. Bearings require UNIREX N3 grease every 2.5 years or 20,000 hours.