Operating Instructions — vacuum pump (BA 231-EN, ed. 1.3 4.7.2018, EN)

Technical Reference Summary

Covered Models & Document Scope

This document covers the oil-flooded rotary vane vacuum pumps V-VC 40, V-VC 50, V-VC 75, V-VC 100 and V-VC 150. It includes the standard design as well as the variants 'IV' (reduced final vacuum, no gas ballast valve) and 'XD' (increased water vapour compatibility, glass-fibre reinforced slide gates, increased gas ballast quantity, higher oil sump temperature).

Section-by-Section Technical Breakdown

pp. 12-14
Set up and operation

Describes the main components and their locations, the data plate, the functional description of the pump including the micro filter, oil mist separator, non-return valve, gas ballast valve, and the areas of application with permissible intake pressure ranges for standard, IV and XD designs.

  • Components: vacuum connection (A), exhaust air outlet (B), suction flange (D), cooling air inlet (E), cooling air outlet (F), oil filling point (H), oil sight glass (I), oil discharge point (K), oil separator elements (L: 3x for V-VC 40/50/75, 4x for V-VC 100/150), oil recommendation plate (M), data plate (N), rotation direction arrow (O), drive motor (P), motor data plate (P1), hot surfaces >70°C (Q), oil remover housing (T), gas ballast valve (U).
  • Standard pump intake pressure range: 0.5 to 500 mbar (abs.); design 'IV': <100 mbar (abs.); design 'XD': 3.0 to 500 mbar (abs.).
  • When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal suction capacity.
  • For permanent operation >100 mbar (abs.), the next larger motor output must be used.
  • If switched on frequently (about 10 times an hour) or at higher ambient/intake temperatures, the excess temperature limit of the motor winding and bearings may be exceeded; contact manufacturer.
pp. 15-17
Installation

Covers preparation for installation, installation requirements, connecting pipes, filling with lubricating oil, and connecting the motor. Includes clearance requirements, foundation conditions, pipe connection limitations, oil filling procedure, and electrical connection details.

  • Cooling air inlets and outlets must be at least 30 cm away from adjacent walls; maintenance space of at least 40 cm around the machine.
  • Machine must be set up horizontally; foundation must be level, straight, and able to bear the machine weight.
  • Counter pressures on the outlet side are only permissible up to +0.1 bar.
  • Fill lubricating oil via oil filling point up to the upper edge of the sight glass.
  • Electrical installation must be by a qualified electrician observing EN 60204; motor protection switch required.
  • Permissible voltage deviation ±5%, frequency deviation ±2% without derating.
pp. 18-19
Commissioning and decommissioning

Describes commissioning steps including checking rotation direction, topping up oil, and decommissioning/storing procedures. Also covers re-commissioning checks.

  • Check rotation direction: when looking at the motor fan, it must rotate clockwise; use a phase sequence indicator.
  • After correcting rotation direction, start motor and stop after 2 minutes to top up oil to the upper edge of the sight glass; repeat until all oil pipes are filled.
  • Decommissioning: switch off, close cut-off devices, disconnect from electricity, depressurise, remove pipes, seal connections.
  • Re-commissioning: check condition, drain preserving agents.
pp. 20-26
Maintenance and repair

Provides maintenance intervals and procedures for air filtering, coupling, lubrication, and oil removal. Includes oil change intervals, oil types, oil separator element replacement, and spare parts information.

  • Maintenance intervals: monthly check pipes/screws, terminal box, clean ventilation slots; daily check oil level; at least once a year check coupling wear; 500-2000 h change oil; 2000 h change oil separator elements.
  • Oil viscosity must comply with ISO VG 100 as per DIN ISO 3448.
  • Recommended oils: MULTI-LUBE 100 (standard mineral), SUPER-LUBE 100 (synthetic for high thermal load), ECO-LUBE 100 (synthetic for food/pharma with H1 certificate).
  • First oil change after 500 hours; subsequent oil changes after 500-2000 hours depending on contamination.
  • Oil separator elements: replace every 2000 operating hours or when filter resistance is 0.7 bar; use ring spanner 19 mm or 3/4".
  • Coupling sprocket must be checked at least once a year; replace if damaged or worn.
pp. 30
Technical data

Lists sound pressure levels, weights, dimensions, connection sizes, and oil quantities for each model. Refers to data sheets D 231 and D 231-30 for more technical data.

  • Sound pressure level (max.) at 50 Hz: 66 dB(A) for V-VC 40/50/75, 70 dB(A) for V-VC 100, 72 dB(A) for V-VC 150; at 60 Hz: 70, 70, 70, 72, 74 dB(A) respectively.
  • Weights: 55 kg (V-VC 40/50), 71 kg (V-VC 75), 115 kg (V-VC 100/150).
  • Vacuum connection: G 1 1/4 for V-VC 40/50, G 1 1/2 for V-VC 75/100/150; exhaust air outlet: G 1 1/4 for V-VC 40/50, G 2 for V-VC 75/100/150.
  • Correct amount of oil: 3.0 l for V-VC 40/50/75, 3.5 l for V-VC 100/150.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Permissible intake pressure range for standard pump: 0.5 to 500 mbar (abs.); design 'IV': <100 mbar (abs.); design 'XD': 3.0 to 500 mbar (abs.). p.14 ↗ Select the correct variant for the intended operating vacuum range to avoid oil leakage through the outlet opening. V-VC 40/50/75/100/150 standard, IV, XD
When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal suction capacity. p.14 ↗ Size the pump accordingly for evacuation tasks to prevent overheating or oil leakage. All models
For permanent operation >100 mbar (abs.), the next larger motor output must be used. p.14 ↗ Select a larger motor if continuous operation above 100 mbar is required. All models
Counter pressures on the outlet side are only permissible up to +0.1 bar. p.16 ↗ Ensure exhaust line is adequately sized and free from restrictions to avoid exceeding back pressure limit. All models
Cooling air inlets and outlets must be at least 30 cm away from adjacent walls; maintenance space of at least 40 cm around the machine. p.15 ↗ Provide sufficient clearance during installation for cooling and maintenance access. All models
Permissible voltage deviation ±5%, frequency deviation ±2% without derating. p.17 ↗ Verify mains supply quality; outside these limits, derating or consultation with manufacturer is required. All models
Oil viscosity must comply with ISO VG 100 as per DIN ISO 3448. p.23 ↗ Use only oils with the specified viscosity to ensure proper lubrication and pump performance. All models
First oil change after 500 hours; subsequent oil changes after 500-2000 hours depending on contamination. p.23 ↗ Plan maintenance intervals based on operating conditions and contamination level. All models
Oil separator elements must be replaced every 2000 operating hours or when filter resistance is 0.7 bar. p.24 ↗ Monitor filter resistance and replace elements to prevent increased pump temperatures and potential oil ignition. All models
Oil separator elements quantity: 3x for V-VC 40/50/75, 4x for V-VC 100/150. p.12 ↗ Order correct number of spare elements for maintenance. V-VC 40/50/75/100/150
Correct amount of oil: 3.0 l for V-VC 40/50/75, 3.5 l for V-VC 100/150. p.30 ↗ Use correct oil quantity when filling or changing oil. V-VC 40/50/75/100/150
Vacuum connection: G 1 1/4 for V-VC 40/50, G 1 1/2 for V-VC 75/100/150; exhaust air outlet: G 1 1/4 for V-VC 40/50, G 2 for V-VC 75/100/150. p.30 ↗ Select mating pipe fittings accordingly. V-VC 40/50/75/100/150
Sound pressure level (max.) at 50 Hz: 66 dB(A) for V-VC 40/50/75, 70 dB(A) for V-VC 100, 72 dB(A) for V-VC 150; at 60 Hz: 70, 70, 70, 72, 74 dB(A) respectively. p.30 ↗ Use ear protection when spending long time near running machine; consider acoustic measures if required. V-VC 40/50/75/100/150
When installed at more than 1000 m above sea level, a reduction in power is noticeable; contact manufacturer. p.15 ↗ Account for altitude derating in system design. All models
If the unit is switched on more frequently (about 10 times an hour) or at higher ambient/intake temperatures, the excess temperature limit of the motor winding and bearings may be exceeded. p.14 ↗ Consult manufacturer for such operating conditions to avoid motor damage. All models
The machine must only be operated at an ambient temperature and a suction temperature of between 12 and 40 °C. p.7 ↗ Ensure installation environment and intake air temperature are within this range; contact manufacturer for temperatures outside this range. All models
Storage ambient conditions: relative humidity 0% to 80%, storage temperature -10 °C to +60 °C. p.11 ↗ Store machine in a dust-free and vibration-free area within these conditions. All models
For long-term storage (more than 3 months), use a preservation oil rather than operating oil. p.11 ↗ Protect machine during extended storage periods. All models
Motor protection switch with delayed switch off recommended to accommodate temporary excess current when starting cold. p.17 ↗ Select motor protection switch that allows short-term excess current at startup. All models
The coupling sprocket must be checked at least once a year; replace if damaged or worn. p.22 ↗ Regular inspection prevents rotor shaft breakage due to defective coupling. All models

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Machine is switched off by the motor protection switch p.27 ↗ Mains voltage/ Frequency does not correspond with the motor data Check by qualified electrician Section 5.5
Machine is switched off by the motor protection switch p.27 ↗ Connection to motor terminal board is not correct Check by qualified electrician Section 5.5
Machine is switched off by the motor protection switch p.27 ↗ Motor protection switch is not set correctly Check by qualified electrician Section 5.5
Machine is switched off by the motor protection switch p.27 ↗ Motor protection switch is triggered too quickly Use a motor protection switch with an overload-dependent delayed switch off that takes into consideration the short term excess current at start up (version with short circuit and overload trigger as per IEC/EN 60947-4-1 or VDE 0660 Part 102)
Machine is switched off by the motor protection switch p.27 ↗ Vacuum pump or its oil is too cold Note the ambient temperature and the intake temperature Section 2.3
Machine is switched off by the motor protection switch p.27 ↗ The lubricating oil is too viscous The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 Section 7.2.3
Machine is switched off by the motor protection switch p.27 ↗ The air oil removers are dirty. Change the oil separator elements Section 7.2.4
Machine is switched off by the motor protection switch p.27 ↗ The back pressure in the exhaust line is too high. Check the hose or the pipe Section 5.3
Machine is switched off by the motor protection switch p.27 ↗ Permanent operation >100 mbar (abs.). Use next largest motor output Section 4.3
Suction capacity is insufficient p.27 ↗ The suction pipe is too long or too narrow Check the hose or the pipe Section 5.3
Suction capacity is insufficient p.27 ↗ Leak on the suction side of the vacuum pump or in the system Check the pipework and screw connections for leaks and to ensure that they are firmly seated. Section 7.2
Suction capacity is insufficient p.27 ↗ The intake filter is dirty Clean or replace the intake filter Section 7.2.1
Final pressure (max. vacuum) is not reached p.28 ↗ Leak on the suction side of the vacuum pump or in the system Check the pipework and screw connections for leaks and to ensure that they are firmly seated. Section 7.2
Final pressure (max. vacuum) is not reached p.28 ↗ Incorrect oil viscosity The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 Section 7.2.3
Machine gets too hot p.28 ↗ Ambient or intake temperature is too high Ensure it is being used properly Section 2.3
Machine gets too hot p.28 ↗ Cooling air supply is obstructed Check environmental conditions Section 5.1
Machine gets too hot p.28 ↗ Cooling air supply is obstructed Clean ventilation slots Section 7.2
Machine gets too hot p.28 ↗ The lubricating oil is too viscous The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 Section 7.2.3
Machine gets too hot p.28 ↗ The air oil removers are dirty. Change the oil separator elements Section 7.2.4
Machine gets too hot p.28 ↗ The back pressure in the exhaust line is too high. Check the hose or the pipe Section 5.3
Exhaust air contains visible oil mist p.28 ↗ The air oil remover devices are not inserted correctly or the O rings are missing. Check that it is correctly seated Section 7.2.4
Exhaust air contains visible oil mist p.28 ↗ Unsuitable oil is being used Use suitable types Section 7.2.3
Exhaust air contains visible oil mist p.28 ↗ The air oil removers are dirty. Change the oil separator elements Section 7.2.4
Exhaust air contains visible oil mist p.28 ↗ Ambient or intake temperature is too high Ensure it is being used properly Section 2.3
Exhaust air contains visible oil mist p.28 ↗ Cooling air supply is obstructed Check environmental conditions Section 5.1
Exhaust air contains visible oil mist p.28 ↗ Cooling air supply is obstructed Clean ventilation slots Section 7.2
The vacuum pump produces a abnormal noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the oper p.29 ↗ The pump housing is worn (chatter marks) Repair by manufacturer or authorised workshop Elmo Rietschle Service
The vacuum pump produces a abnormal noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the oper p.29 ↗ The vacuum adjustment valve (if available) is vibrating Replace the valve Section 7.4
The vacuum pump produces a abnormal noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the oper p.29 ↗ Blades are damaged Repair by manufacturer or authorised workshop Elmo Rietschle Service
The vacuum pump produces a abnormal noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the oper p.29 ↗ Vacuum pump or its oil is too cold Note the ambient temperature and the intake temperature Section 2.3
The vacuum pump produces a abnormal noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the oper p.29 ↗ The lubricating oil is too viscous The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 Section 7.2.3
Water in lubricating oil p.29 ↗ Pump sucks in water Install water interceptor upstream of the pump
Water in lubricating oil p.29 ↗ The pump sucks in more water vapour than is suitable for its water vapour compatibility Contact the manufacturer for increased gas ballast
Water in lubricating oil p.29 ↗ Pump only works for a short time and therefore does not reach its normal operating temperature Let the pump continue to run with a closed suction side after extracting the water vapour until the water has evaporated from the oil