Operating Instructions — VCS 400 vacuum pump (BA 233-EN, ed. 2.0 28/08/2023, EN)
Technical Reference Summary
Covered Models & Document Scope
Covers oil-flooded rotary vane vacuum pumps V-VCS 400, 500, 700, 900, 1100 and 1300 (single-stage, driven by flanged three-phase standard motor). Variants: V-VCS 400–900 (standard), V-VCS 1100–1300, and V-VCS 1100–1300 with additional oil separator housing (required for rough vacuum operation on 1100–1300). Document edition 2.0, 28/08/2023, BA 233-EN.
Section-by-Section Technical Breakdown
The V-VCS 400–1300 are single-stage oil-flooded rotary vane vacuum pumps. The rotary vane divides the housing into chambers; oil seals the gap, lubricates and dissipates compression heat. Suction side has a micro-fine or fine-mesh filter; outlet side has an oil and oil-mist separator returning oil to the circulation. A fan and oil cooler cool oil and housing; an integrated non-return valve prevents ventilation of the evacuated system after stop. A standard gas ballast valve prevents condensation of small water-vapour quantities at operating temperature; an enlarged gas ballast is available from factory. The data plate encodes model/size, serial number, year of construction, data matrix barcode, article number, speed 50/60 Hz, motor output 50/60 Hz, operating mode, pumping capacity 50/60 Hz and final pressure 50/60 Hz.
- Single-stage oil-flooded rotary vane design, driven via coupling by flanged three-phase standard motor
- Integrated non-return valve prevents back-venting of the evacuated system after pump stop
- Standard gas ballast valve; enlarged gas ballast provided at factory for higher water-vapour volumes
- VCS 1100–1300 require an additional oil separator housing for rough vacuum operation
- Data plate includes article number, serial number, speed, motor output, pumping capacity and final pressure at 50/60 Hz
Nominal pumping capacity at 50 Hz with free intake is 400 m³/h (VCS 400), 550 m³/h (VCS 500), 700 m³/h (VCS 700), 830 m³/h (VCS 900), 1,100 m³/h (VCS 1100) and 1,280 m³/h (VCS 1300). The pumps are suitable for evacuating closed systems or for continuous vacuum within defined fine-vacuum and rough-vacuum intake pressure ranges. Continuous operation outside these ranges risks oil leaking through the outlet. When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal pumping capacity.
- V-VCS 400–900 fine vacuum: 0.5 to 100 mbar (abs.); rough vacuum: 10 to 500 mbar (abs.)
- V-VCS 1100–1300 fine vacuum: 1 to 100 mbar (abs.); rough vacuum: 20 to 500 mbar (abs.)
- Closed-system evacuation volume ≤ 2% of nominal pumping capacity
- For continuous operation > 100 mbar (abs.), use the next higher motor output
- Frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits — contact manufacturer
Installation requires free access from all sides, unobstructed ventilation grids, no external vibration, no intake of hot exhaust air from other machines, good room ventilation, and at least 50 cm space around the machine for maintenance. The machine must be set up horizontally (max. inclination 1° in all directions), secured against tipping/falling, on a plane floor able to carry its weight. Cooling air inlets/outlets must be at least 30 cm from adjacent walls. Pipes must be screwed in by hand only; flexible connections are recommended. The exhaust air opening must not be closed or restricted, no filter may be installed on the exhaust side, and counterpressure must not exceed +100 mbar. Lubricating oil is filled via both oil filling points up to the upper edge of the oil sight glass.
- Max. installation inclination: 1° in all directions; machine must be horizontal
- Minimum 50 cm free space around machine for maintenance
- Cooling air inlets/outlets at least 30 cm from adjacent walls; cooling air must not be recirculated
- Exhaust air opening must not be closed or restricted; no filter on exhaust side; counterpressure max. +100 mbar
- Remove blind plugs on suction connection and exhaust air outlet before connecting pipes
- Screw pipes in by hand only; use flexible connections if necessary
- Fill oil via both oil filling points up to the upper edge of the oil sight glass
- Output reduction noticeable above 1000 m above sea level — contact manufacturer
Electrical installation must be carried out by a qualified electrician observing EN 60204. The operating company must install the main switch and a motor protection switch. Motors comply with DIN EN 60034, protection class IP 55 and insulation class F; the connection diagram is in the motor terminal box (not present for plug-connection version). Machines with AC motors above 1.7 kVA apparent output, three-phase motors above 5.2 kVA, or motors with starting currents above 60 A are not designed for direct-on-line starting; star-delta starting, soft starter or frequency converter must be used. Permissible tolerances are ±5% voltage deviation and ±2% frequency deviation from nominal.
- Electrical installation per EN 60204 by qualified electrician; main switch and motor protection switch installed by operating company
- Motor protection class IP 55, insulation class F, DIN EN 60034
- Direct-on-line start not permitted for AC motors > 1.7 kVA, three-phase motors > 5.2 kVA, or starting currents > 60 A
- Use star-delta starting, soft starter or frequency converter for high starting torques
- Permissible voltage deviation ±5%, frequency deviation ±2% from nominal
- Direction of rotation must match the rotation arrow on the motor flange
- Motor protection circuit breakers with delayed switch-off recommended due to temporary excess current at cold start
Start-up requires an installation check, verification of motor rotation direction, and setting of the operating range (fine vacuum / rough vacuum). During operation the oil level must be checked through the oil sight glass. Surface temperatures on components may exceed 70 °C at operating temperature and are marked with warning signs. The installation room must be well ventilated because extracted air contains a small residue of oil aerosols. Operation is only allowed with sufficient cooling air flow.
- Check installation, rotation direction and operating range setting before start-up
- Check oil level through oil sight glass during operation
- Surface temperatures may exceed 70 °C — marked with warning signs; wear protective gloves if necessary
- Installation room must be well ventilated due to residual oil aerosols in extracted air
- Operation only with sufficient cooling air quantity; cooling air flow must not be interrupted
Maintenance covers cleaning the vacuum pump, cleaning filter cartridges in the filter housing, cleaning the mesh filter in the suction flange and the filter cartridge of the gas ballast valve, lubricating oil (refilling and oil change), air-oil separator elements, motor and coupling. A maintenance table defines intervals. Repairs are only allowed by authorised workshops using original spare parts. Spare parts are listed in document E 233.
- Maintenance table defines required intervals (chapter 7.2)
- Clean mesh filter in suction flange and filter cartridge of gas ballast valve
- Oil viscosity must comply with ISO VG 100 as per DIN ISO 3448
- Change air-oil separator elements when dirty
- Replace worn coupling rubbers
- Repairs only by authorised workshops using original spare parts; otherwise guarantee expires
- Spare parts list: document E 233
Technical data are provided in chapter 10 and in data sheet D 233 (technical data and characteristic curves). Key data include nominal pumping capacities at 50 Hz, intake pressure ranges, motor protection class IP 55, insulation class F, ambient and inlet temperature range 5–40 °C, permissible counterpressure +100 mbar, and storage temperature -10 °C to +60 °C.
- Nominal pumping capacity at 50 Hz: 400 / 550 / 700 / 830 / 1,100 / 1,280 m³/h for VCS 400 / 500 / 700 / 900 / 1100 / 1300
- Ambient and inlet temperature range: 5 to 40 °C
- Permissible counterpressure: +100 mbar
- Storage temperature: -10 °C to +60 °C; relative air humidity max. 80%
- Motor protection class IP 55, insulation class F
- Data sheet D 233 contains technical data and characteristic curves
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Ambient and inlet temperature must be between 5 and 40 °C. p.8 ↗ | Operation outside this range requires consultation with the manufacturer; otherwise overheating or oil viscosity issues may occur. | V-VCS 400–1300 |
| Permissible counterpressure on the exhaust side is +100 mbar maximum. p.8 ↗ | Exhaust lines must be sized to avoid exceeding +100 mbar; no filter may be installed on the exhaust side. | V-VCS 400–1300 |
| Fine vacuum range V-VCS 400–900: 0.5 to 100 mbar (abs.); rough vacuum range: 10 to 500 mbar (abs.). p.18 ↗ | Continuous operation outside these ranges risks oil leaking through the outlet opening. | V-VCS 400, 500, 700, 900 |
| Fine vacuum range V-VCS 1100–1300: 1 to 100 mbar (abs.); rough vacuum range: 20 to 500 mbar (abs.). p.18 ↗ | For rough vacuum operation of VCS 1100–1300, an additional oil separator housing must be installed. | V-VCS 1100, 1300 |
| When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal pumping capacity. p.18 ↗ | Larger volumes require a larger pump or a different evacuation strategy. | V-VCS 400–1300 |
| For continuous operation > 100 mbar (abs.), the next higher motor output should be used. p.18 ↗ | Motor selection must account for continuous operation above 100 mbar. | V-VCS 400–1300 |
| Maximum installation inclination is 1° in all directions; machine must be set up horizontally. p.19 ↗ | Mounting surface must be plane and even; machine must be secured against tipping and falling. | V-VCS 400–1300 |
| Cooling air inlets and outlets must be at least 30 cm away from adjacent walls. p.19 ↗ | Ensure sufficient clearance and prevent recirculation of cooling air to avoid overheating. | V-VCS 400–1300 |
| Provide at least 50 cm space around the machine for maintenance work. p.19 ↗ | Installation layout must allow access to filter housing, oil filling points, oil sight glass, oil drain, gas ballast and de-oiler housing. | V-VCS 400–1300 |
| Permissible voltage deviation ±5% and frequency deviation ±2% from nominal. p.21 ↗ | Mains conditions at installation site must comply with motor data plate; otherwise loss of power or damage may occur. | V-VCS 400–1300 |
| Direct-on-line starting is not permitted for AC motors with apparent output > 1.7 kVA, three-phase motors > 5.2 kVA, or motors with starting currents > 60 A. p.21 ↗ | Use star-delta starting, soft starter or frequency converter for such motors. | V-VCS 400–1300 |
| Motor protection class IP 55, insulation class F, compliant with DIN EN 60034. p.21 ↗ | Suitable for indoor installation; if installed in open air, protect from environmental influences (e.g. protective roof). | V-VCS 400–1300 |
| Oil viscosity must comply with ISO VG 100 as per DIN ISO 3448. p.30 ↗ | Use only recommended lubricating oil; incorrect viscosity can cause insufficient pumping capacity, overheating or excessive noise. | V-VCS 400–1300 |
| Storage temperature: -10 °C to +60 °C; relative air humidity max. 80%; store dust-free, dry, vibration-free and protected from sun radiation. p.13 ↗ | Do not store for more than 6 months; for long-term storage (>3 months) use preservation oil rather than operating oil. | V-VCS 400–1300 |
| Nominal pumping capacity at 50 Hz with free intake: 400 m³/h (VCS 400), 550 m³/h (VCS 500), 700 m³/h (VCS 700), 830 m³/h (VCS 900), 1,100 m³/h (VCS 1100), 1,280 m³/h (VCS 1300). p.18 ↗ | Use these values for sizing and selection; data sheet D 233 shows dependency on intake pressure. | V-VCS 400–1300 |
| The machine does not have its own Emergency Stop or Emergency Off; this must be implemented by the user. p.11 ↗ | Integrate the machine into the user's safety plan with appropriate emergency stop/off devices. | V-VCS 400–1300 |
| Output reduction is noticeable when installed at more than 1000 m above sea level. p.19 ↗ | Contact manufacturer for installation at altitudes above 1000 m. | V-VCS 400–1300 |
| Frequent switching at regular intervals of approx. 10 times per hour or high ambient/inlet temperatures may exceed the excess temperature limit of motor winding and bearings. p.18 ↗ | Contact manufacturer for such operating conditions. | V-VCS 400–1300 |
Faults & Troubleshooting
| Code / Symptom | Possible Cause | Remedy | Note |
|---|---|---|---|
| Machine is switched off by the motor protection switch p.36 ↗ | Mains voltage/ Frequency does not correspond with the motor data | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.36 ↗ | Connection to motor terminal board is not correct | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.36 ↗ | Motor protection switch is not set correctly | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.36 ↗ | Motor protection switch is triggered too quickly | Use a motor protection switch with an overload-dependent delayed switch off that takes into consideration the short term excess current at start up (version with short circuit and overload trigger as per IEC 60947-4-1) | |
| Machine is switched off by the motor protection switch p.36 ↗ | Vacuum pump or its oil is too cold | Note the ambient temperature and the inlet temperature | Chapter 2.4 |
| Machine is switched off by the motor protection switch p.36 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| Machine is switched off by the motor protection switch p.36 ↗ | The oil separator elements are dirty. | Change the oil separator elements | Chapter 7.7 |
| Machine is switched off by the motor protection switch p.36 ↗ | The back pressure in the exhaust line is too high | Check the hose and/or the pipe | Chapter 5.3 |
| Pumping capacity is insufficient p.36 ↗ | The inlet pipe is too long or too narrow | Check the hose and/or the pipe | Chapter 5.3 |
| Pumping capacity is insufficient p.36 ↗ | Leak on the inlet side of the vacuum pump or in the system | Check the pipework and screw connections for leaks and check for tight fit | Chapter 7.2 |
| Pumping capacity is insufficient p.36 ↗ | The intake filter is dirty | Clean or replace the intake filter | Chapter 7.5 |
| Final pressure (max. vacuum) is not reached p.37 ↗ | Leak on the inlet side of the vacuum pump or in the system | Check the pipework and screw connections for leaks and check for tight fit | Chapter 7.2 |
| Final pressure (max. vacuum) is not reached p.37 ↗ | Incorrect oil viscosity | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| Final pressure (max. vacuum) is not reached p.37 ↗ | Adjust the bolt for fine/coarse vacuum if not set correctly | Set the operating range correctly | Kapitel 6.1.3 |
| Machine gets too hot p.37 ↗ | Ambient or inlet temperatures too high | Ensure proper use | Chapter 2.4 |
| Machine gets too hot p.37 ↗ | Cooling air supply is obstructed | Check ambient conditions | Chapter 5.1 |
| Machine gets too hot p.37 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Chapter 7.4 |
| Machine gets too hot p.37 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| Machine gets too hot p.37 ↗ | The oil separator elements are dirty. | Change the oil separator elements | Chapter 7.7 |
| Machine gets too hot p.37 ↗ | The back pressure in the exhaust line is too high | Check the hose and/or the pipe | Chapter 5.3 |
| Exhaust air contains visible oil mist p.37 ↗ | The oil separator elements are not inserted correctly or the O rings are missing. | Check that it is correctly seated | Chapter 7.7 |
| Exhaust air contains visible oil mist p.37 ↗ | Unsuitable oil is being used | Use suitable types | Chapter 7.6 |
| Exhaust air contains visible oil mist p.37 ↗ | The oil separator elements are dirty | Change the oil separator elements | Chapter 7.7 |
| Exhaust air contains visible oil mist p.37 ↗ | Ambient or inlet temperatures too high | Ensure proper use | Chapter 2.4 |
| Exhaust air contains visible oil mist p.37 ↗ | Cooling air supply is obstructed | Check ambient conditions | Chapter 5.1 |
| Exhaust air contains visible oil mist p.37 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Chapter 7.2 |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.37 ↗ | The coupling rubbers are worn | Replace the coupling rubbers | Kapitel 7.8.2 |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.37 ↗ | The pump housing is worn (chatter marks) | Repair by manufacturer or authorised workshop | Elmo Rietschle Service |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.37 ↗ | The vacuum adjustment valve (if available) is vibrating | Replace the valve | Chapter 7.10 |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.37 ↗ | The Blades are damaged | Repair by manufacturer or authorised workshop | Elmo Rietschle Service |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.37 ↗ | Vacuum pump or its oil is too cold | Note the ambient temperature and the inlet temperature | Chapter 2.4 |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.37 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| Water in lubricating oil p.38 ↗ | Pump sucks in water | Install water interceptor upstream of the pump | — |
| Water in lubricating oil p.38 ↗ | The pump sucks in more water vapour than is suitable for its water vapour compatibility | Contact the manufacturer for increased gas ballast | Elmo Rietschle Service |
| Water in lubricating oil p.38 ↗ | Pump only works for a short time and therefore does not reach its normal operating temperature | Let the pump continue to run with a closed suction side after extracting the water vapour until the water has evaporated from the oil | — |