Operating Instructions — C-DLR 301 compressor (BA 887-EN, ed. 2.0 20/01/2023, EN)
Technical Reference Summary
Covered Models & Document Scope
C-DLR 301 contact-free running claw compressor, including the standard version and the variant with integrated frequency converter (variants Fxxx). The document covers machines without frequency converter and machines with frequency converter (frequency converter INVEOR M).
Section-by-Section Technical Breakdown
The C-DLR 301 is a double-shaft, contact-free rotary claw compressor. The counter-rotating claw rotors are synchronised by an oil-lubricated gear pair in a gearbox; the compression chamber is dry and separated from the gearbox by special seals. Cooling air is drawn through the insulation hood by a drum fan. Machines with frequency converter have the converter mounted on the motor for infinitely variable speed control.
- Contact-free, dry-running claw rotors synchronised by a gear pair in an oil-filled gearbox.
- Gearbox and compression chamber separated by special seals; gearbox sealed with piston sealing rings and O-rings.
- Intake air cleaned by a filter cartridge; intake silencer on the inlet side; connecting thread on the outlet side.
- Cooling by drum fan drawing fresh air between compressor and insulation hood and discharging heated air at the cooling air outlet.
- Driven via coupling by a flanged three-phase standard motor.
- Frequency converter version allows infinitely variable speed control.
- Safety valve installed as standard for overload protection.
The data plate encodes model/size, serial number, year of construction, article number, speed, motor output, operating mode, volume flow and excess pressure. Machines with frequency converter have an additional data plate for the frequency converter showing frequency range and speed range. A data matrix barcode encodes material number, production order and serial number.
- Standard data plate fields: model/size (mechanical version), serial number, year of construction, data matrix barcode, article No., speed, motor output, operating mode, volume flow, excess pressure.
- Frequency converter data plate adds frequency range and speed range.
- Barcode encodes material number (MA), production order (PR) and serial number (SC).
- Data plates must not be removed, even if the machine is resold.
Installation requires a horizontal setup with maximum inclination of 8° in all directions, sufficient free space and unobstructed cooling air. Pipes must be connected without excessive force; flexible connections are recommended. The machine must be connected to the energy supply by a qualified electrician according to EN 60204, with a motor protection switch provided by the operating company.
- Machine freely accessible from all sides; ventilation grids and holes must not be closed.
- Provide at least 40 cm space around the machine for maintenance.
- Set up horizontally; maximum inclination 8° in all directions.
- Cooling air inlets and outlets at least 30 cm from adjacent walls; cooling air must not be recirculated.
- Ambient temperature min. +5 °C, max. +40 °C.
- Only screw in pipes by hand; use flexible connections if necessary.
- For connection lines longer than 3 m with the same pipe cross-section, a non-return valve is recommended to avoid reverse running after switch-off.
- Electrical installation per EN 60204 by a qualified electrician; main switch and motor protection switch provided by the user.
- Motors comply with DIN EN 60034, protection class IP 55, insulation class F.
- Without frequency converter: voltage tolerance ±5 %, frequency tolerance ±2 %.
- With frequency converter: input voltage 3~ AC 400 V -15 % to 480 V +10 %, input frequency 47 to 63 Hz ±0 %, network configurations TN/TT, protection class IP 65.
Before start-up, an installation check must confirm stable horizontal mounting, correct pipe connections, tight screw and flange connections, correct electrical installation, adequate ventilation, oil level and cleanliness. The direction of rotation must be checked briefly (max. two seconds); when looking at the motor blower it must rotate counter-clockwise. Decommissioning requires disconnection from power, depressurisation and sealing of connections.
- Installation check includes transport/assembly damage, stable horizontal position, leak-tight pipe connections, tight screw and flange connections, electrical installation per connection diagram, adequate ventilation, oil level and cleanliness.
- Check direction of rotation with a phase sequence indicator; drive shaft direction shown by arrow on motor flange.
- Brief start max. two seconds; when looking at the motor blower it must rotate counter-clockwise.
- Machine may only be switched on again after it stands still.
- Decommissioning: switch off, allow to cool, close cut-off devices, disconnect power, depressurise by opening pipes slowly, remove pipes and hoses, seal connections with adhesive foil.
Maintenance work must only be carried out with the machine disconnected from power and secured against restart. The maintenance table, cleaning, oil level check and oil change, air filter, motor and coupling, safety valve and frequency converter are covered. Repair work is only allowed by authorised specialists using original spare parts.
- Disconnect machine from power and secure against accidental switching before any maintenance work.
- Works on electrical installation or components only by an electrician.
- Repair works only by authorised specialists.
- Oil level checked through oil sight glass; fill at oil filling point up to the middle of the sight glass.
- Safety valve must be functional; operation without safety valve is not intended use.
- Spare parts list E 887 available from Gardner Denver.
The manual provides a table of malfunctions with causes and remedies. It covers motor protection switch trips, frequency converter error messages, insufficient volumetric flow, failure to reach final pressure, overheating and strange noises. For malfunctions not listed or not remediable, contact Elmo Rietschle Service.
- Never put the compressor back into operation after an automatic switch-off until the cause has been found and remedied.
- Motor protection switch may trip due to incorrect mains voltage/frequency, incorrect motor terminal connection, incorrect setting, or too-fast trip; use an overload-dependent turn-off delay considering start-up excess current (VDE 0660 Part 102 or IEC 60947-4-1).
- Frequency converter error messages: see operating instructions of the frequency converter.
- Insufficient volumetric flow can be caused by dirty intake filter, too long or too narrow pressure line, or leaks.
- Final pressure not reached can be caused by leaks, dirty intake filter, or too-low driving power selection.
- Overheating can be caused by high ambient/inlet temperatures, obstructed cooling air supply, dirty ventilation slots, or a dirty safety valve causing excess pressure.
- Strange noises can be caused by deposits on the rotary piston, a floating safety valve, or a damaged coupling.
Technical data are provided in chapter 10 and in data sheet D 889 (or D 887-60 for the frequency converter version). The compressor has a flow rate of 290 m³/h at 50 Hz. Load limits are stated on the data plate. Noise emission is given as sound pressure level dB(A) per EN ISO 3744.
- Flow rate 290 m³/h at 50 Hz.
- Excess pressure range from 0 bar up to the maximum pressure on the data plate.
- Constant operation is permissible.
- Data sheet D 889 or D 887-60 shows flow rate dependence on overpressure.
- Noise emission measured as sound pressure level dB(A) per EN ISO 3744.
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Ambient and inlet temperature must be between 5 and 40 °C. p.8 ↗ | Operation outside this range requires consultation with the manufacturer; ensure installation room ventilation and cooling air supply. | C-DLR 301 all variants |
| Maximum inclination during operation is 8° in all directions; machine must be set up horizontally. p.18 ↗ | Mount on a plane, even floor; secure against tipping and falling. | C-DLR 301 all variants |
| Cooling air inlets and outlets must be at least 30 cm away from adjacent walls; cooling air must not be recirculated. p.18 ↗ | Prevents overheating due to insufficient cooling capacity. | C-DLR 301 all variants |
| Provide at least 40 cm space around the machine for maintenance work. p.18 ↗ | Ensures access to oil filling point, oil sight glass and oil drain. | C-DLR 301 all variants |
| For connection lines longer than 3 m with the same pipe cross-section, a non-return valve is recommended to avoid reverse running after switch-off. p.19 ↗ | Prevents reverse rotation after shutdown; suitable non-return valves (accessories ZRK) available from Service. | C-DLR 301 all variants |
| Without frequency converter: voltage tolerance ±5 % and frequency tolerance ±2 % referred to nominal value, unless otherwise specified on the motor data plate. p.20 ↗ | Verify mains network matches motor data before connection. | C-DLR 301 without frequency converter |
| With frequency converter: input voltage 3~ AC 400 V -15 % to 480 V +10 %, input frequency 47 to 63 Hz ±0 %, network configurations TN/TT. p.20 ↗ | Ensure supply network complies; use suitable cable fittings to maintain IP 65. | C-DLR 301 with frequency converter |
| Motors comply with DIN EN 60034, protection class IP 55, insulation class F. p.20 ↗ | Suitable for industrial environments; electrical connection per terminal box diagram. | C-DLR 301 without frequency converter |
| Direction of rotation check: start motor briefly (max. two seconds); when looking at the motor blower it must rotate counter-clockwise. p.22 ↗ | Wrong direction of rotation may damage the machine; use a phase sequence indicator. | C-DLR 301 all variants |
| Machine may only be switched on again after it stands still. p.21 ↗ | Restart while coasting down can damage the machine. | C-DLR 301 all variants |
| Oil level must be filled up to the middle of the oil sight glass. p.19 ↗ | Check oil level before commissioning and top up if necessary; use suitable oil types per chapter 7.5. | C-DLR 301 all variants |
| Flow rate is 290 m³/h at 50 Hz. p.17 ↗ | Reference value for system design; actual flow depends on overpressure per data sheet D 889 or D 887-60. | C-DLR 301 |
| Frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed the excess temperature limit of motor winding and bearings. p.17 ↗ | Contact manufacturer for such operating conditions. | C-DLR 301 all variants |
| Output reduction is noticeable when installed at more than 1000 m above sea level. p.18 ↗ | Contact manufacturer for high-altitude installations. | C-DLR 301 all variants |
| Storage temperature: -20 °C to +70 °C; relative air humidity max. 80 %; storage in dry, dust-free, vibration-free place protected from sun radiation; do not store for more than 6 months. p.13 ↗ | Observe storage conditions to avoid material damage. | C-DLR 301 all variants |
| Surface temperatures on components may rise above 70 °C during operation. p.21 ↗ | Hot surfaces are marked with warning signs; wear protective gloves and avoid touching. | C-DLR 301 all variants |
| The machine does not have its own Emergency Stop or Emergency Off; this must be implemented by the user, e.g. by integration into the user's safety concept. p.11 ↗ | User must provide emergency stop/off function in the plant. | C-DLR 301 all variants |
| Motor protection switch must be provided by the operating company; use a motor protection switch with overload-dependent turn-off delay considering short excess current at start-up (VDE 0660 Part 102 or IEC 60947-4-1). p.19 ↗ | Prevents nuisance tripping during cold starts. | C-DLR 301 all variants |
Faults & Troubleshooting
| Code / Symptom | Possible Cause | Remedy | Note |
|---|---|---|---|
| Machine is switched off by the motor protection switch p.31 ↗ | Mains voltage/ Frequency does not correspond with the motor data | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.31 ↗ | Connection to motor terminal board is not correct | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.31 ↗ | Motor protection switch is not set correctly | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.31 ↗ | Motor protection switch is triggered too quickly | Use a motor protection switch with an overload-dependent turn-off delay that considers the short excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 102 or IEC 60947-4-1) | |
| Machine is switched off by the motor protection switch p.31 ↗ | The safety valve is dirty so that the permissible pressure is exceeded | See Operating Instructions of safety valve | |
| Machine does not start or the frequency converter displays an error message p.31 ↗ | Malfunctions in the integrated frequency converter | See Operating Instructions of frequency converter | |
| Machine does not start or the frequency converter displays an error message p.31 ↗ | The safety valve is dirty so that the permissible pressure is exceeded | See Operating Instructions of safety valve | |
| The volumetric flow rate is not sufficient p.31 ↗ | The intake filter is dirty | Clean / replace intake filter | Chapter 7.6 |
| The volumetric flow rate is not sufficient p.31 ↗ | The pressure line is too long or too narrow | Check the hose and/or the pipe | Chapter 5.3 |
| The volumetric flow rate is not sufficient p.31 ↗ | Machine or system leaking | Check the pipework and screw connections for leaks and check for tight fit | Chapter 5.3 |
| Final pressure (max. excess pressure) has not been reached p.31 ↗ | Machine or system leaking | Check the pipework and screw connections for leaks and check for tight fit | Chapter 5.3 |
| Final pressure (max. excess pressure) has not been reached p.31 ↗ | The intake filter is dirty | Clean / replace intake filter | Chapter 7.6 |
| Final pressure (max. excess pressure) has not been reached p.31 ↗ | Driving power selection too low | Use next largest motor output | Data sheet D 889 / D 887-60 |
| Machine gets too hot p.32 ↗ | Ambient or inlet temperatures too high | Ensure proper use | Chapter 2.4 |
| Machine gets too hot p.32 ↗ | Cooling air supply is obstructed | Check ambient conditions | Chapter 5.1 |
| Machine gets too hot p.32 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Chapter 7.4 |
| Machine gets too hot p.32 ↗ | The safety valve is dirty so that the permissible pressure is exceeded | See Operating Instructions of safety valve | |
| The machine makes a strange noise p.32 ↗ | Deposits on the rotary piston | Clean the working space and the rotary piston | Elmo Rietschle Service |
| The machine makes a strange noise p.32 ↗ | Safety valve is floating | Replace the valve | |
| The machine makes a strange noise p.32 ↗ | Coupling is damaged | Replace coupling |