Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Oil-flooded rotary vane vacuum pumps V-VCB 20 and V-VCB 25 with IE3 flange motors, 50 Hz and 60 Hz, 3~ voltages (230/400 V, 220/380 V, 200/346 V, 200/230 V, 400 V, 230/460 V, 330/380/660 V, 220/380/440 V, 200/400/690 V, 230/400/460 V)

Technical Data

Parameter Value Condition
Suction capacity 20 m³/h p.2 ↗ V-VCB 20, 50 Hz
Suction capacity 24 m³/h p.2 ↗ V-VCB 25, 50 Hz
Suction capacity 24 m³/h p.2 ↗ V-VCB 20, 60 Hz
Suction capacity 26,5 m³/h p.2 ↗ V-VCB 25, 60 Hz
Ultimate vacuum 2 mbar (abs.) p.2 ↗ V-VCB 20 / 25
Rated voltage 230 / 400 V p.2 ↗ 3~, ±10%
Rated voltage 220 / 380 V p.2 ↗ 3~, ±10%
Motor rating 0,75 kW p.2 ↗ V-VCB 20 / 25, 50 Hz
Motor rating 0,9 kW p.2 ↗ V-VCB 20 / 25, 60 Hz
Current drawn 3,52 / 2,03 A p.2 ↗ V-VCB 20, 60 Hz
Motor efficiency 84,5 % p.2 ↗ V-VCB 20, 60 Hz
Speed 2850 min⁻¹ p.2 ↗ 50 Hz
Speed 3420 min⁻¹ p.2 ↗ 60 Hz
Average noise level 63 dB(A) p.2 ↗ V-VCB 20, 50 Hz, EN ISO 3744
Average noise level 62 dB(A) p.2 ↗ V-VCB 25, 50 Hz, EN ISO 3744
Average noise level 64 dB(A) p.2 ↗ V-VCB 20, 60 Hz, EN ISO 3744
Average noise level 66 dB(A) p.2 ↗ V-VCB 25, 60 Hz, EN ISO 3744
Max. weight 21 kg p.2 ↗ V-VCB 20
Max. weight 23 kg p.2 ↗ V-VCB 25
Oil capacity 0,35 l p.2 ↗ V-VCB 20 / 25
Protection class IP 55 p.1 ↗ flange motor
Insulation class F p.1 ↗ flange motor

Operating Limits

  • Ultimate vacuum: 2 mbar (abs.) p.2 ↗
  • Rated voltage tolerance: ±10% p.2 ↗
  • Protection class: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.1 ↗ V-VCB Product series: oil-flooded rotary vane vacuum pump
7-8 p.1 ↗ 20 / 25 Size (nominal suction capacity class)
voltage field p.2 ↗ Vx / Sx / Ux / Tx Voltage variant: Vx = 200/346 V Δ, 200/230 V Y, 400 V; Sx = 200/230 V Δ, 400 V Y, 230/460 V; Ux = 330/380/660 V Δ, 220/380/440 V Y; Tx = 200/400/690 V Δ, 230/400/460 V Y