Product introduction and main features of the chiller
Specpp. 1-2
Technical data according to DIN 12876
p. 2table, 3 rows
p. 1table, 33 rows
Technical data according to DIN 12876
Parameter
Value
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.:
1.0/26
Unichiller GL 750w — Technical data according to DIN 12876
Parameter
Value
Operating temperature range
-20...40 °C
temperature set point / display
5,7" colour Touchscreen
Internal temperature sensor
Pt100
Sensor external connection
Pt100
Temperature stability at -10°C
0,2 K
Interface digital
Ethernet, USB (Host u. Device), RS232
Safety classification
I / NFL
Cooling power at 20°C
75 kW
Refrigeration machine
water-cooled, natural refrigerant
Refrigerant (ASHRAE, GHS)
R-744 (A1, H280)
Global Warming Potential (GWP)
1
UN-number
UN 2857
max. delivery
320 l/min
max. delivery pressure
4 bar
Delivery at 0,5 bar
305 l/min
Delivery at 1,0 bar
285 l/min
Delivery at 1,5 bar
260 l/min
Delivery at 2,0 bar
240 l/min
Delivery at 2,5 bar
215 l/min
Delivery at 3,0 bar
185 l/min
Delivery at 3,5 bar
150 l/min
Delivery at 4,0 bar
110 l/min
Delivery at 4,5 bar
50 l/min
Pump connection
G1 1/4 male
Cooling water connection
G1 1/4 male
min. cooling water differential pressure
1 bar
max. cooling water pressure
6 bar
min. filling capacity
17,5 l
Volume of expansion
50 l
Overall dimensions WxDxH **
918x963x1771 mm
Power supply (3 Phase)
400V 3~ 50Hz
Pressure equipment category
II
Degree of Protection
IP20
** Overall dimensions WxDxH
Engineering Facts
14 facts · every claim linked to a page
Installation
The chiller requires cooling water with a minimum differential pressure of 1 bar and must not exceed 6 bar, so the site water supply must be verified before installation.
Insufficient differential pressure will prevent rated cooling performance and may trip the unit.
Source
“min. cooling water differential pressure 1 bar”
Installation
The unit is water-cooled and needs a cooling water supply between 5°C and 20°C; below the condensation point the cooling water pipes inside the unit must be insulated.
Out-of-range cooling water temperature reduces cooling power and risks condensation inside the unit.
Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Performance
Rated output data are valid only at 20°C room temperature, 15°C cooling water inlet and 1 bar differential pressure, so actual capacity will differ at other site conditions.
Selection must account for derating when site conditions deviate from the reference point.
Source
“Output data valid for: Room temperature 20°C, cooling water inlet 15°C and 1 bar differential pressure between cooling water inlet and -”
Installation
The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible cooling water may be used.
Incompatible water chemistry can corrode or foul the circuit and void performance.
Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Compliance
Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and the combination of -5% voltage with +2% frequency is not allowed.
Supply quality must be checked against this asymmetric tolerance before commissioning.
Source
“-5% voltage and +2% frequency -> not allowed!”
Safety
The unit has a leakage current greater than 3.5 mA, which affects protective earthing and RCD selection.
Earth connection and residual current device rating must be sized accordingly.
Source
“Attention: leakage current > 3,5mA”
Installation
Three-phase devices below 63 A are delivered with a cable but without a plug, so the customer must provide the plug and connection.
Electrical installation scope and materials must be planned by the site.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Operation
The unit is IP20 and must be installed indoors protected from water ingress.
IP20 limits installation locations and requires protection from splashing or dripping water.
Source
“Degree of Protection IP20”
Selection
The refrigerant is R-744 (CO2) with GWP 1 and is classified A1/H280, which affects refrigerant handling and safety classification.
Refrigerant safety class and GWP influence site safety requirements and environmental compliance.
Source
“R-744 (A1, H280)”
Selection
The pump delivers 320 l/min maximum but only 110 l/min at 4.0 bar, so the system curve must be matched to the required pressure.
External circuit pressure drop determines the achievable flow and must be checked during selection.
Source
“Delivery at 4,0 bar 110 l/min”
Installation
The minimum filling capacity is 17.5 l and the expansion volume is 50 l, which sets the minimum external loop volume and expansion allowance.
External loop volume and expansion vessel sizing must respect these limits.
Source
“min. filling capacity 17,5 l”
Operation
The ambient temperature range is 5°C to 40°C, so the installation room must be kept within these limits.
Ambient conditions outside the range affect cooling performance and reliability.
Source
“max. ambient temperature 40 °C”
Compliance
The equipment is EMC Class A Group 1, which is intended for industrial environments and may cause interference in residential areas.
Class A equipment has restrictions on use in residential environments.
Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Safety
The unit has adjustable overtemperature protection according to DIN 12876, which must be set for the application.
Overtemperature protection setting is a safety requirement for the connected process.
Source
“With adjustable overtemperature protection according to DIN 12876.”