Technical data according to DIN 12876 — Unichiller P010w (Order-No.: 3050.0018.01)
Parameter
Value
Operating temperature range
-20...40 °C
temperature set point / display
5,7" colour Touchscreen
Internal temperature sensor
Pt100
Sensor external connection
Pt100
Temperature stability at -10°C
0,5 K
Interface digital
Ethernet, USB (Host u. Device), RS232
Safety classification
I / NFL
Cooling power at ambient temperature +20°C
at 15°C
1 kW
at 0°C
0,8 kW
at -10°C
0,5 kW
at -20°C
0,15 kW
Refrigeration machine
water-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)
R-449A (A1, H280)
Global Warming Potential (GWP)
1397
Refrigerant quantity
0,2 kg
CO2 equivalent
0,3 t
Circulation pump
B
max. delivery
25 l/min
max. delivery pressure
2,5 bar
Delivery at 0,5 bar
21 l/min
Delivery at 1,0 bar
17 l/min
Delivery at 1,5 bar
11 l/min
Delivery at 2,0 bar
6 l/min
Pump connection
G3/4 male
Cooling water connection
G1/2 male
min. cooling water differential pressure
1 bar
max. cooling water pressure
6 bar
min. filling capacity
3,8 l
Volume of expansion
1,7 l
Overall dimensions WxDxH **
350x496x622 mm
** сноска в исходном тексте не раскрыта
Engineering Facts
12 facts · every claim linked to a page
Installation
The unit requires cooling water with a differential pressure of at least 1 bar and no more than 6 bar, so the site water supply must be verified before installation.
Insufficient or excessive cooling water pressure will prevent proper operation or damage the unit.
Source
“min. cooling water differential pressure 1 bar”
Installation
The cooling water intake temperature must be between 5°C and 20°C, and pipes must be insulated if the water can fall below the dew point.
Out-of-range cooling water temperature reduces cooling capacity and can cause condensation.
Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Performance
Cooling power drops significantly as the required temperature decreases, from 1 kW at +15°C to only 0.15 kW at -20°C.
The engineer must confirm that the available cooling capacity at the target temperature meets the process load.
Source
“Cooling power at ambient temperature +20°C”
Operation
The plastic pump is not resistant to acetone or polyglycols, so these fluids must not be used without a special upgraded pump.
Using incompatible heat transfer fluids will damage the pump and void reliable operation.
Source
“The plastic pump is not resistant against acetone and polyglycols (depending on the manufacturer).”
Operation
For freeze protection, water should be mixed with glysantine or ethylene glycol rather than relying on pure water.
Proper antifreeze selection prevents freezing and damage in the cooling circuit at low temperatures.
Source
“It is recommended that water is mixed with either glysantine or ethylene glycol for freeze protection.”
Compliance
Voltage and frequency tolerances must be applied simultaneously: ±5% voltage with ±2% frequency, but opposite-sign deviations are not allowed.
The site power supply must be checked against this combined tolerance to avoid motor and electronics stress.
Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Installation
The unit is rated IP20, so it must be installed in a dry indoor location protected from water ingress.
IP20 offers no water protection, so the installation environment must be dry and clean.
Source
“Degree of Protection IP20”
Safety
The refrigerant R-449A is classified A1 with GHS hazard H280, meaning it is non-flammable but stored under pressure.
Personnel must be aware of the pressurized refrigerant hazard during handling and service.
Source
“R-449A (A1, H280)”
Selection
The unit has a minimum filling capacity of 3.8 liters and an expansion volume of 1.7 liters, which determines the required heat transfer fluid volume.
The engineer must plan for at least this fluid volume and account for thermal expansion.
Source
“min. filling capacity 3,8 l”
Installation
The pump connections are G3/4 male and cooling water connections are G1/2 male, so matching hose couplings must be provided.
Correct thread matching avoids leaks and ensures proper connection during installation.
Source
“Pump connection G3/4 male”
Operation
The maximum ambient temperature for operation is 40°C and the minimum is 5°C, so the installation room must stay within this range.
Operating outside the ambient range can reduce performance or cause unit faults.
Source
“max. ambient temperature 40 °C”
Compliance
The equipment emits electromagnetic disturbance classified as Class A, Group 1 per EN55011, which may require separation from sensitive equipment.
Class A equipment may cause interference in residential environments and needs appropriate EMC planning.
Source
“Classification (disturbance) to EN55011: Class A, Group 1”