Unistat 635w Technical Data

Contents

  1. Overview p. 1
    Product introduction and general description of the Unistat 635w unit
  2. Spec pp. 1-2
    Technical specifications and performance data per DIN 12876
  3. p. 2 table, 18 rows
  4. p. 1 table, 33 rows

Technical data according to DIN 12876

ParameterValue
max. permissible kin. viscosity100 mm²/s
Cooling water connectionG3/4 male
min. cooling water differential pressure1 bar
max. cooling water differential pressure4 bar
max. cooling water pressure6 bar
max. System pressure6 bar
min. filling capacity8,9 l
Filling capacity expansion tank19,9 l
Overall dimensions WxDxH **918x963x1771 mm
Net weight721 kg
Power supply requirement400V 3~ 50Hz
max. current56 A
Fuse3x63A
Pressure equipment categoryII
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S569436

** Please respect space requirements. See operating conditions at www.huber-online.com

Technical data according to DIN 12876

CharacteristicValue
Operating temperature range-60...200 °C
Temperature stability at -10°C0,01 K
temperature set point / display5,7" colour Touchscreen
Resolution of display0,01 K
Internal temperature sensorPt100
Sensor external connectionPt100
Interface digitalEthernet, USB (Host u. Device), RS232
digital inputECS ONE
digital outputPOKO ONE
Interface analogoptional
Alarm messageoptic, acoustic, relay
Safety classificationIII / FL
Heating power24 kW
Cooling power with Thermooil at 200°C27 kW
Cooling power with Thermooil at 100°C27 kW
Cooling power with Thermooil at 20°C27 kW
Cooling power with Ethanol at 0°C27 kW
Cooling power with Ethanol at -20°C25 kW
Cooling power with Ethanol at -40°C14 kW
Cooling power with Ethanol at -60°C3,5 kW
Refrigeration machinewater-cooled, natural refrigerant
Refrigerant (ASHRAE, GHS)R-1270 (A3, H220)
Global Warming Potential (GWP)0
Refrigerant quantity2,56 kg
CO2 equivalent0,0 t
Circulation pump:MK pump
max. delivery196 l/min
max. delivery pressure2,5 bar
Delivery at 0,5 bar175 l/min
Delivery at 1,0 bar152 l/min
Delivery at 1,5 bar123 l/min
Delivery at 2,0 bar86 l/min
Pump connectionM38x1,5 male

Engineering Facts

14 facts · every claim linked to a page
Installation

The unit requires a 400 V 3~ 50 Hz supply with a 3x63 A fuse and draws up to 56 A, so the electrical installation must be sized accordingly.

Determines feeder cable, breaker and upstream distribution capacity before installation.

Source
“Power supply requirement 400V 3~ 50Hz max. current 56 A Fuse 3x63A”
Installation

Cooling water must be supplied at 1–4 bar differential pressure and no more than 6 bar static pressure through G3/4 male connections.

Ensures the facility cooling water loop can meet flow and pressure limits without overpressurizing the unit.

Source
“min. cooling water differential pressure 1 bar max. cooling water differential pressure 4 bar max. cooling water pressure 6 bar”
Operation

Rated cooling capacity is only valid at 20 °C room temperature, 15 °C cooling water inlet and 1 bar differential pressure, and the unit is designed for 5–20 °C cooling water intake.

Prevents overestimating cooling performance if site cooling water is warmer than the reference conditions.

Source
“Output data valid for: Room temperature 20°C, cooling water inlet 15°C and 1 bar differential pressure between cooling water inlet and -outlet. This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Installation

If cooling water temperature can fall below the condensation point, the cooling water pipes inside the unit must be insulated.

Avoids condensation and corrosion risk when chilled water is used.

Source
“When cooling water temperatures fall below the condensation point, it is essential to insulate the cooling water pipes in the unit.”
Installation

The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible cooling water may be used.

Guides water quality and treatment to prevent corrosion or fouling of the cooling circuit.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM. Please use suitable cooling water.”
Compliance

Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and certain combinations such as -5% voltage with +2% frequency are not allowed.

Defines acceptable site power quality and protects the compressor and electronics from out-of-tolerance supply.

Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2% Example -5% voltage and +2% frequency -> not allowed!”
Safety

Leakage current exceeds 3.5 mA, which affects protective earthing and RCD selection.

Requires proper earth connection and consideration of residual current device type and rating.

Source
“Attention: leakage current > 3,5mA”
Installation

Three-phase devices below 63 A are delivered with cable but without plug, so a suitable plug must be provided on site.

Prevents installation delay because no mating plug is included.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Selection

The unit uses R-1270 refrigerant (A3, H220) with GWP 0 and a charge of 2.56 kg, which has safety implications for the installation room.

A3 flammable refrigerant affects room classification, ventilation and safety planning.

Source
“Refrigerant (ASHRAE, GHS) R-1270 (A3, H220) Global Warming Potential (GWP) 0 Refrigerant quantity 2,56 kg”
Selection

The pump delivers 196 l/min maximum and 86 l/min at 2.0 bar, with M38x1.5 male connections, which must match the external circuit pressure drop.

Ensures the external loop flow and pressure drop are within pump capability.

Source
“max. delivery 196 l/min max. delivery pressure 2,5 bar Delivery at 2,0 bar 86 l/min Pump connection M38x1,5 male”
Installation

The unit weighs 721 kg and measures 918x963x1771 mm, so floor loading and access route must be checked.

Affects rigging, doorway clearance and structural floor capacity.

Source
“Overall dimensions WxDxH ** 918x963x1771 mm Net weight 721 kg”
Operation

Ambient temperature must stay between 5 °C and 40 °C and the unit is IP20, so it must be installed in a dry indoor location.

Defines the permissible environment and prevents ingress of water or dust.

Source
“Degree of Protection IP20 min. ambient temperature 5 °C max. ambient temperature 40 °C”
Maintenance

The maximum permissible kinematic viscosity of the heat transfer fluid is 100 mm²/s, which limits fluid selection at low temperatures.

Prevents pump overload and poor circulation when choosing thermal fluid.

Source
“max. permissible kin. viscosity 100 mm²/s”
Installation

Minimum filling capacity is 8.9 l and the expansion tank holds 19.9 l, which sets the minimum fluid charge and expansion allowance.

Ensures enough fluid volume and expansion space for safe operation.

Source
“min. filling capacity 8,9 l Filling capacity expansion tank 19,9 l”