HiPace 1800 with TC 1200 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum HiPace 1800 and HiPace 2300 turbomolecular vacuum pumps. Three-page product datasheet covering technical data (pumping speeds, compression ratios, gas throughputs), mechanical/mounting specifications, interfaces, and available accessories/options for corrosive applications (nickel-coated surfaces).
Section-by-Section Technical Breakdown
Marketing-oriented overview positioning the HiPace 1800/2300 as high-performance, flexible, and robust turbomolecular pumps. Emphasizes high pumping speed, excellent compression for light gases, hybrid bearing technology, and nickel-coated surfaces for corrosive applications.
- High performance: high pumping speed, excellent compression for light gases
- Flexible: extensive portfolio, standard accessories and communication tools
- Robust: best-in-class hybrid bearing technology, maximum uptime
- Nickel-coated surfaces available for corrosive applications
- Accessories and options: electrical adapter, mains cable, connecting cable, display unit, safety and mounting kits, venting accessories, sealing gas accessories
Full performance data for both models across N₂, H₂, He and Ar: pumping speeds, compression ratios, gas throughputs at final rotational speed and at 0.1 hPa HV pressure, plus maximum permissible forevacuum pressure for N₂.
- Pumping speed N₂: 1450 l/s (HiPace 1800), 1900 l/s (HiPace 2300)
- Pumping speed H₂: 1700 l/s / 1850 l/s; He: 1650 l/s / 2000 l/s; Ar: 1370 l/s / 1800 l/s
- Compression ratios identical for both models: N₂ 1·10⁸, H₂ 2·10⁴, He 3·10⁵, Ar 1·10⁸
- Gas throughput at final rotational speed: N₂ 28 hPa·l/s, H₂ 50 hPa·l/s, He 20 hPa·l/s, Ar 16 hPa·l/s (both models)
- Gas throughput at 0.1 hPa HV pressure: N₂ 38 hPa·l/s, H₂ 14 hPa·l/s, He 26 hPa·l/s (both models)
- Maximum forevacuum pressure for N₂: 1.8 hPa (both models)
Mechanical and connectivity data: run-up time, sound pressure level, weight, communication interfaces, permissible mounting orientation, and flange sizes for both models.
- Run-up time: 4 min for both models
- Sound pressure level (EN ISO 2151): 50 dBA for both models
- Weight: approx. 37.8 kg (HiPace 1800), 36.6 kg (HiPace 2300)
- Standard communication interfaces: RS-485 and remote (both models)
- Mounting orientation: 0° (HV flange top) – 90° / 90° – 180° (HV flange bottom)
- Gas inlet/outlet HiPace 1800: DN 200 ISO-K/ISO-F / DN 40 ISO-KF
- Gas inlet/outlet HiPace 2300: DN 250 ISO-K/ISO-F/CF-F / DN 40 ISO-KF
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| HiPace 1800 pumping speed is 1450 l/s for N₂; HiPace 2300 reaches 1900 l/s for N₂. p.2 ↗ | Select HiPace 2300 when N₂ throughput demands exceed ~1450 l/s; size backing pump and conductance accordingly. | HiPace 1800 and HiPace 2300 |
| Compression ratio for H₂ is only 2·10⁴ for both models (vs 1·10⁸ for N₂ and Ar). p.2 ↗ | Hydrogen ultimate pressure depends strongly on foreline pressure; ensure an adequately low forevacuum pressure for UHV/light-gas applications. | whole series |
| Maximum permissible forevacuum pressure for N₂ is 1.8 hPa for both models. p.2 ↗ | Backing pump must maintain foreline pressure ≤1.8 hPa at full gas throughput to avoid loss of compression or rotor overload. | whole series |
| Gas throughput at final rotational speed for H₂ is 50 hPa·l/s, the highest of all listed gases (N₂ 28, He 20, Ar 16 hPa·l/s). p.2 ↗ | Size backing pumps and safety relief based on the H₂ case when hydrogen processes are involved. | whole series |
| Gas throughput at 0.1 hPa HV pressure for N₂ is 38 hPa·l/s (both models). p.2 ↗ | Defines continuous process load capacity at elevated HV pressure; relevant for transition-region process sizing. | whole series |
| Run-up time to full speed is 4 minutes for both models. p.3 ↗ | Account for ~4 min delay before full pumping performance; relevant for process cycle timing and interlock logic. | whole series |
| Sound pressure level is 50 dBA per EN ISO 2151 for both models. p.3 ↗ | Below typical 80 dBA workplace limits; no special acoustic enclosure generally required. | whole series |
| Weights are approx. 37.8 kg (HiPace 1800) and 36.6 kg (HiPace 2300). p.3 ↗ | Two-person handling or lifting equipment recommended for mounting; flange/support loading must be designed for ~38 kg. | HiPace 1800 and HiPace 2300 |
| Permissible mounting orientation spans 0°–90° and 90°–180°, i.e. HV flange up through HV flange down. p.3 ↗ | Pumps can be installed in any orientation from horizontal to flange-down; no orientation-specific variant is needed. | whole series |
| HiPace 1800 uses DN 200 ISO-K/ISO-F inlet; HiPace 2300 uses DN 250 ISO-K/ISO-F/CF-F inlet; both use DN 40 ISO-KF forevacuum outlet. p.3 ↗ | Flange hardware, seals, and backing-line sizing (DN 40) must match the model; CF-F option on the 2300 enables metal-seal UHV systems. | HiPace 1800 (DN 200) and HiPace 2300 (DN 250) |
| Standard communication interfaces are RS-485 and remote for both models. p.3 ↗ | Plan control integration via RS-485 (e.g. Pfeiffer protocol) or hardwired remote I/O; no other interfaces listed as standard in this document. | whole series |
| Nickel-coated surfaces are offered for corrosive applications. p.1 ↗ | Specify the nickel-coated variant for corrosive-process pumps; standard surfaces are not rated for such service. | whole series (option) |
| Available accessories include venting accessories and sealing gas accessories. p.1 ↗ | For corrosive or particulate processes, plan venting and sealing-gas (purge) kits in the installation design from the start. | whole series |
| He pumping speed of HiPace 2300 (2000 l/s) exceeds its N₂ speed (1900 l/s), while HiPace 1800 peaks at H₂ (1700 l/s) over N₂ (1450 l/s). p.2 ↗ | For helium-dominated loads the HiPace 2300 offers a clear advantage; verify per-gas performance rather than N₂ figures alone. | HiPace 1800 and HiPace 2300 |