HiPace 2800 IT with TC 1200 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum HiPace 2800 IT and HiPace 3400 IT turbomolecular pumps, IT versions specially designed for ion implantation systems and optimized for light gases (H₂, He). Document is a 3-page datasheet/brochure with technical data, accessories/options list, and marketing highlights; no ordering codes given.
Section-by-Section Technical Breakdown
Highlights the pumps' suitability for ion implantation systems with optimized pumping of light gases. Robustness features include an integrated heating system, nickel-coated surfaces for corrosive applications, and hybrid bearing technology for long life.
- Specially designed for ion implantation systems, optimized for pumping light gases
- Integrated heating system, suitable for harsh processes, reduced condensation
- Nickel-coated surfaces for corrosive applications
- Best-in-class hybrid bearing technology, long life cycle, maximum uptime
Detailed performance data for N₂, H₂, He and Ar: pumping speeds, compression ratios, gas throughput at final rotational speed and at 0.1 hPa HV pressure, and maximum forevacuum pressure for N₂. Most values are identical for both models.
- Pumping speed N₂: 2300 l/s (HiPace 2800 IT) / 3200 l/s (HiPace 3400 IT)
- Pumping speed H₂: 2600 / 2900 l/s; He: 2900 / 3200 l/s; Ar: 2100 / 2900 l/s
- Compression ratios (both models): N₂ 1·10⁸, H₂ 4·10³, He 6·10⁴, Ar 1·10⁸
- Gas throughput at final rotational speed (both): N₂ 18, H₂ 75, He 24, Ar 12 hPa·l/s
- Gas throughput at 0.1 hPa HV pressure (both): N₂ 50, H₂ 42, He 62 hPa·l/s
- Max. forevacuum pressure for N₂ (both): 0.8 hPa
Run-up time, noise level, weight, interfaces, allowed mounting orientations and flange sizes for both models. HiPace 3400 IT uses a larger inlet flange and is heavier.
- Run-up time: 8.6 min for both models
- Sound pressure level (EN ISO 2151): 50 dBA for both models
- Weight: approx. 62 kg (2800 IT) / 65 kg (3400 IT)
- Standard communication interfaces: RS-485, remote
- Mounting orientation: 0° (HV flange top) – 90° / 90° – 180° (HV flange bottom)
- Gas inlet/outlet: DN 250 ISO-F / DN 40 ISO-KF (2800 IT); DN 320 ISO-F / DN 40 ISO-KF (3400 IT)
List of available accessories and options for the HiPace 2800/3400 IT series. No part numbers are given in this document.
- Electrical adapter
- Mains cable
- Connecting cable
- Display unit
- Safety and mounting kits
- Venting accessories
- Sealing gas accessories
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Pumping speed for N₂ is 2300 l/s (HiPace 2800 IT) and 3200 l/s (HiPace 3400 IT) p.2 ↗ | Model selection depends mainly on required N₂ throughput; the 3400 IT gives ~40% more N₂ pumping speed | whole series |
| H₂ pumping speed exceeds N₂ speed: 2600 l/s (2800 IT) and 2900 l/s (3400 IT) p.2 ↗ | Confirms optimization for light gases such as hydrogen in ion implantation applications | whole series |
| Compression ratio for H₂ is only 4·10³ vs 1·10⁸ for N₂ and Ar p.2 ↗ | Hydrogen requires adequate backing pump performance; foreline H₂ partial pressure will limit ultimate pressure | whole series |
| Maximum forevacuum pressure for N₂ is 0.8 hPa (both models) p.2 ↗ | Backing pump must maintain ≤0.8 hPa foreline pressure for safe operation | whole series |
| Gas throughput at final rotational speed for H₂ is 75 hPa·l/s, the highest of all listed gases p.2 ↗ | High continuous H₂ throughput capability; size backing line accordingly | whole series |
| Gas throughput at 0.1 hPa HV pressure: He 62, N₂ 50, H₂ 42 hPa·l/s (both models) p.2 ↗ | Defines throughput capacity during process operation at moderate HV pressures | whole series |
| Run-up time is 8.6 min for both models p.3 ↗ | Full pumping performance available ~9 min after start; relevant for process scheduling | whole series |
| Sound pressure level is 50 dBA per EN ISO 2151 p.3 ↗ | Low noise; generally no special acoustic measures needed at typical installation distances | whole series |
| Weight is approx. 62 kg (HiPace 2800 IT) and 65 kg (HiPace 3400 IT) p.3 ↗ | Two-person lift or lifting equipment required for mounting | whole series |
| Mounting orientation allowed: 0° (HV flange top) to 90°, and 90° to 180° (HV flange bottom) p.3 ↗ | Pump can be installed with inlet up, horizontal, or down; verify support and accessories per orientation | whole series |
| Gas inlet/outlet: DN 250 ISO-F / DN 40 ISO-KF (2800 IT); DN 320 ISO-F / DN 40 ISO-KF (3400 IT) p.3 ↗ | 3400 IT needs a DN 320 ISO-F chamber flange and matching adapter; outlet is DN 40 ISO-KF for both | HiPace 2800 IT vs HiPace 3400 IT |
| Standard communication interfaces are RS-485 and remote p.3 ↗ | Integrate via RS-485 or hardwired remote control; no other interfaces listed as standard | whole series |
| Integrated heating system reduces condensation, suitable for harsh processes p.1 ↗ | Use the heating function in implantation/process environments to protect against condensation | whole series |
| Nickel-coated surfaces for corrosive applications p.1 ↗ | Suitable for corrosive process gases without additional external coating | whole series (IT variant) |
| Hybrid bearing technology is used p.1 ↗ | Long bearing life cycle and maximum uptime; relevant for maintenance interval planning | whole series |
| Accessories include venting accessories and sealing gas accessories p.1 ↗ | Plan for venting and sealing-gas provisions in installation design for corrosive/ionic processes | whole series |