Agilent TriScroll Variable Speed Dry Pumps

Contents

  1. Overview pp. 1-2
    Introduces variable speed dry pump technology and target applications
  2. Overview p. 2
    Lists analytical instrumentation applications such as MALDI/TOF and LC/MS/MS
  3. Spec p. 4
    Peak pumping speed and performance data tables
  4. p. 4 table, 10 rows

Triscroll inverter – Technical Specification

TS300invTS600inv
Peak pumping speed250 l/m, 15 m3/hr (8.8 cfm)500 l/m, 30m3/h (17.7 cfm)
Ultimate pressure1.3 x 10-2 mbar (10 mTorr)9.3 x 10-3 mbar (7 mTorr)
Inlet connectionNW25NW40
Exhaust connection1⁄4" Female NPT with swivel3⁄8" Female NPT with swivel
NW16 (adapter provided)NW25 (adapter provided)
Gas ballast1⁄4" Female NPT
Weight – pump only26 kg (57 lb.)31 kg (68 lbs)
Power requirementsSingle phase 200-240 VAC, 50-60 Hz, 5 amps (max)
Operating speed40-62 Hz (factory setting) : 1800 RPM
Noise level per ISO 11201, variable w/frequency55-68 dBA

Engineering Facts

13 facts · every claim linked to a page
Selection

The pump speed can be finely tuned to match the optimum working pressure at the mass spectrometer inlet, simplifying retrofit with existing rotary vane pumps.

Allows engineers to match existing system pumping characteristics and avoid redesign during retrofit.

Source
“The pumping speed can be finely adjusted to deliver the optimum working pressure at the mass spectrometer inlet”
Performance

Rotational speed is adjustable to the nearest 1 Hz, giving precise control of pumping speed.

Precise speed control is essential for tuning inlet pressure in high-gas-flow API mass spectrometers.

Source
“The TriScroll Inverter pumps adjust rotational speed to the nearest 1 Hz for precise control of pumping speed”
Operation

The pump provides constant pumping speed worldwide regardless of line frequency.

Ensures consistent performance across 50 Hz and 60 Hz power grids without reconfiguration.

Source
“Constant pumping speed worldwide regardless of line frequency”
Installation

Remote start and stop is possible via a contact closure using a standard D-shell connector.

Enables integration with system control electronics without additional interface hardware.

Source
“Remote start and stop with a contact closure made possible by a standard D-shell connector”
Operation

Pump parameters can be monitored via a serial interface.

Supports remote diagnostics and system-level monitoring in automated laboratory setups.

Source
“Monitoring of pump parameters via serial interface”
Performance

Operating at lower rotational speeds significantly reduces noise in the work area with little loss in base pressure performance.

Allows quieter operation without sacrificing vacuum quality, important for laboratory environments.

Source
“Significant decrease in noise levels in the work area resulting from pump’s operation at lower rotational speeds with little loss in base pressure performance of the pump.”
Maintenance

Long-life tip seals routinely last more than a year before replacement.

Reduces maintenance frequency and cost of ownership compared to oil-sealed rotary vane pumps.

Source
“Long-life tip seals routinely last more than a year before replacement”
Compliance

Dry TriScroll pumps eliminate oil disposal costs and simplify regulatory and environmental compliance.

Avoids oil handling, disposal, and associated environmental compliance burdens.

Source
“TriScroll Pumps eliminate the frequent maintenance requirements of oil-sealed rotary vane pumps, simplifying regulatory and environmental compliance, and eliminating oil disposal costs”
Installation

The inverter's low power consumption eliminates tripping of circuit breakers caused by high starting current.

Prevents nuisance breaker trips during pump startup, simplifying electrical installation.

Source
“Eliminate tripping of circuit breakers caused by high starting current”
Selection

The TS300inv provides 250 l/m peak pumping speed while the TS600inv provides 500 l/m.

Peak pumping speed is a primary selection criterion for matching the mass spectrometer gas load.

Source
“250 l/m, 15 m3/hr (8.8 cfm)”
Selection

The TS300inv achieves 1.3 x 10-2 mbar ultimate pressure and the TS600inv achieves 9.3 x 10-3 mbar.

Ultimate pressure determines the achievable base vacuum and suitability for the backing application.

Source
“1.3 x 10-2 mbar (10 mTorr)”
Installation

Both pumps require single-phase 200-240 VAC, 50-60 Hz, 5 amps maximum power.

Defines the electrical supply and circuit capacity needed for installation.

Source
“Single phase 200-240 VAC, 50-60 Hz, 5 amps (max)”
Operation

The factory-set operating speed range is 40-62 Hz corresponding to 1800 RPM.

Establishes the default speed range and baseline speed for commissioning and tuning.

Source
“40-62 Hz (factory setting) : 1800 RPM”