Agilent Technologies 1260 Infinity III LC System
Agilent Technologies 1260 Infinity III LC System — Liquid chromatography with Flow rate 0.6 liter/minute, Pumping speed 6×10⁻⁵ m³/h.
The Agilent 1260 Infinity II GPC/SEC System is a quaternary HPLC configuration built around the G7111B pump, G7129A vialsampler with integrated G7130A column compartment, and G7114B variable wavelength detector. It operates at 1.0 mL/min with a 100 µL analytical head and 100 µL injection loop, supporting up to 600 bar and 80 °C column temperature. This modification targets size-exclusion separations requiring stable flow and precise injection volumes.
Agilent Technologies Analytical HPLC Systems Series — Model Comparison & Selection
| Model | Flow rate, liter/minute | Sample volume, milliliter | Column temperature, °C | Data rate, Hz | Operating altitude, m | Weight, kg |
|---|---|---|---|---|---|---|
| 1260 Infinity III LC System Current | 0.6 | 0.005 | 40 | 120 | — | — |
| 1220 Infinity II LC System | — | 1 | 50 | 80 | 2000 | 30 |
| 1260 Infinity III Prime LC System | 9×10⁻⁴ | 0.002 | 40 | 40 | 3000 | 11.5 |
Full specifications
| Detection limit | 0.068 pmol/µL |
| Flow rate | 0.600 mL/min |
| Pumping speed | 1.0 mL/min |
| Analytical Head Volume | 100 µL |
| Baseline Drift | 10...4 AU/h |
| Column Particle Size | 2.7 µm |
| Column temperature | 40 °C |
| Data Rate | 120 Hz |
| Detection wavelength | 254 nm |
| Flow Cell Volume | 14 µL |
| Flow Rate (1220 Infinity Ii Lc) | 10 mL/minute |
| Flow Rate (1290 Infinity Iii Lc) | 5 mL/minute |
| Flow Rate Range | 5 mL/min |
| Injection Loop Volume | 100 µL |
| Maximum operating pressure | 600 bar |
| Peak Area Rsd | 0.20 % |
| Post Time | 1 min |
| Retention Time %rsd | 0.02 % |
| Sample Loop Volume | 100 µL |
| Sample volume | 5 µL |
| Metering device volume mfr | 100 μL |
| Stop time mfr | 15 min |
| FLD cell volume mfr | 8 μL |
| Software version mfr | 2.8 later |
| Calibration range mfr | 2.25...90 pmol/μL |
| Calibration R2 mfr | 0.99999 |
| Binary Pump mfr | High-Speed Pump* |
| Quaternary Pump mfr | Flexible Pump** |
| Solvent Preparation mfr | 1260 Degasser |
| Solvent Delivery mfr | 1260 Pump |
| Valve Solutions mfr | InfinityLab Quick Change Valves Valves |
| Maximum operating pressure (1290 Infinity III LC) mfr | 1300 bar |
| Maximum operating pressure (1260 Infinity III Prime LC) mfr | 800 bar |
| Maximum operating pressure (1260 Infinity III LC) mfr | 400 bar |
| Pressure at 2 mL/min (1290 High-Speed Pump) mfr | 1300 bar |
| Pressure at 5 mL/min (1290 High-Speed Pump) mfr | 800 bar |
| Pressure (1260 Infinity III Flexible Pump) mfr | 800 bar |
| Pressure (1260 Infinity III Binary Pump) mfr | 600 bar |
| Pressure (1260 Infinity III Quaternary Pump VL) mfr | 400 bar |
| Flow rate (1260 Infinity III Quaternary Pump VL) mfr | 10 ml/min |
| Sample capacity (1290 Infinity III Multisampler) mfr | 6144 samples |
| Carryover (1290 Infinity III Multisampler multiwash) mfr | 9 ppm |
| Wavelength range (1290 Infinity III DAD) mfr | 190...640 nm |
| Wavelength range (1260 Infinity III DAD WR) mfr | 190...950 nm |
| ELSD flow range (1290 Infinity III ELSD) mfr | 0.2...5 mL/min |
| RI measurement range (1290 Infinity III RID) mfr | 600 RIU |
| Solvent mfr | 10 Methanol/Water |
| Agilent 1260 Infinity II Multisampler mfr | 28.3784 |
| Agilent 1260 Infinity II Vialsampler mfr | 28.5657 |
| Column Inner Diameter | 2.1 mm |
| Column Length | 50 mm |
| Detector Flow Cell Path Length | 10 mm |
| Flow Cell Path Length | 10 mm |
| Column Compartment Temperature | 80 °C |
| Detector noise mfr | 2.5 μAU |
| Column thermostat range (1290 Infinity III Multicolumn thermostat) mfr | 20...110 °C |
| Column thermostat range (1260 Infinity III Multicolumn thermostat) mfr | 10...85 °C |
Description
Construction and series positioning
- The system is assembled from the G7111B quaternary pump, G7129A vialsampler with integrated G7130A column compartment, and G7114B variable wavelength detector, as described in the 1260 Infinity II LC technical overview.
- Within the 1260 Infinity II series, this GPC/SEC configuration is distinguished by its 100 µL analytical head and 100 µL injection loop, versus the analytical-scale siblings (1220 Infinity II LC, 1260 analytical-scale purification system) that use different injection and flow architectures.
- The quaternary pump supports flow rates up to 5 mL/min and pressures to 600 bar, with a standard 1.0 mL/min operating point for GPC/SEC methods.
Behavior under load and in different modes
- The column compartment maintains up to 80 °C, enabling elevated-temperature GPC/SEC separations; the sample cooler holds samples at 4 °C to preserve polymer solutions.
- The VWD provides a 10 mm path length and 14 µL flow cell volume, with 254 nm detection and 120 Hz data rate; detector noise is 2.5 µAU and baseline drift 10–4 AU/h.
- The injection system uses a 100 µL metering device and 100 µL sample loop, with a 5 µL sample volume specified for typical injections; post-time is 1 min and stop time 3 min.
Installation, connection, and control
- The system is controlled via OpenLab CDS 2.8 or later, as noted in the injector program technical overview; the software version is listed as 2.8.
- The vialsampler integrates the column compartment, reducing external plumbing and dead volume between injection and separation.
- The FLD cell volume is 8 µL, and column dimensions are 2.1 mm, indicating narrow-bore columns are supported alongside standard 2.7 µm particle columns.
Integration & Operating Notes
The quaternary pump and flow path are rated to a maximum operating pressure of 600 bar. Operating above this limit risks seal damage and invalid retention data; method development should keep backpressure below this threshold, especially with narrow-bore columns and high-viscosity GPC solvents.
Automated sample preparation workflows using injector programs require OpenLab CDS version 2.8 or later. Earlier software versions will not execute the injection sequences described in the technical overview, so the data system must be upgraded before commissioning these methods.
The sample cooler is set to 4 °C to preserve thermally labile polymer solutions during extended GPC/SEC runs. Ensure the cooler is operational before loading samples; condensation management and solvent compatibility at low temperature should be verified for the mobile phase in use.
The 100 µL metering device and 100 µL sample loop are matched components; replacing one without the other can shift injection volume accuracy. During scheduled maintenance, verify both volumes and recalibrate the injector using the OpenLab CDS injector calibration routine.
Selection & Integration Q&A
Choose this GPC/SEC configuration when you need a quaternary pump with 100 µL injection loop and integrated column compartment for size-exclusion separations up to 600 bar and 80 °C. The 1220 Infinity II LC is a compact isocratic system for routine HPLC, while the 1260 analytical-scale purification system is optimized for fraction collection, not GPC/SEC.
The system includes the G7114B VWD with a 10 mm path, 14 µL flow cell; GPC/SEC columns with 2.1 mm internal diameter and 2.7 µm particles are supported. Ensure column end-fittings match the low-dead-volume connections of the G7130A column compartment, and use the FLD cell (8 µL) only if fluorescence detection is added.
The base system includes the pump, vialsampler, column compartment, and VWD, but not GPC/SEC columns, guard columns, or solvent filtration kits. OpenLab CDS 2.8 software is required and may be licensed separately. Replacement metering devices (100 µL) and sample loops are consumables; schedule seal and loop replacement per the pump maintenance interval.