Agilent Technologies 1260 Infinity III Prime LC System
Agilent Technologies 1260 Infinity III Prime LC System — Liquid chromatography with Flow rate 9×10⁻⁴ liter/minute, Motor power 0.11 kW.
The 1260 Infinity II GPC/SEC System is a high-performance gel permeation/size-exclusion chromatography system built around a 1260 Infinity II LC platform with a deuterium lamp detector and up to 120 Hz data acquisition. It is positioned between the compact 1220 Infinity II LC and the higher-pressure 1290 Infinity III LC, and is intended for polymer molecular-weight distribution analysis in organic or aqueous GPC/SEC modes.
Agilent Technologies Analytical HPLC Systems Series — Model Comparison & Selection
| Model | Flow rate, liter/minute | Sample volume, milliliter | Column temperature, °C | Data rate, Hz | Operating altitude, m | Weight, kg |
|---|---|---|---|---|---|---|
| 1260 Infinity III Prime LC System Current | 9×10⁻⁴ | 0.002 | 40 | 40 | 3000 | 11.5 |
| 1220 Infinity II LC System | — | 1 | 50 | 80 | 2000 | 30 |
| 1260 Infinity III LC System | 0.6 | 0.005 | 40 | 120 | — | — |
Full specifications
| Flow rate | 0.9 mL/min |
| Motor power | 110 VA |
| Column temperature | 40 °C |
| Data Rate | 40 Hz |
| Energy Consumption | 1282 kJ |
| Light source | Deuterium lamp |
| Maximum Data Acquisition Rate | 120 Hz |
| Operating Hours | 967 Hours |
| Sample volume | 2 µL |
| Water gradient mfr | 2.0 |
| Detection type mfr | 1024 array |
| Number of signals mfr | 8 |
| UV Detector mfr | 240 rate |
| UV detection wavelength mfr | 240 nm |
| Waters pressure rating mfr | 689 bar |
| Weight | 11.5 kg |
| Dimensions (height × width × depth) mfr | 140 mm |
| Line voltage mfr | 100...240 |
| Line frequency mfr | 50 Hz |
| Mobile Phase mfr | A) Water B) Acetonitrile Acetonitrile |
| Operating Altitude | 3000 m |
| Humidity mfr | 95 % r.h. |
Description
Construction and series positioning
- The system is a 1260 Infinity II LC configured for GPC/SEC, using a deuterium lamp source and a 1024-element detection array with 8 signal channels.
- Within the InfinityLab family, it sits above the 1220 Infinity II LC (compact HPLC) and below the 1290 Infinity III LC (UHPLC); it shares the 1260 platform's modularity but is dedicated to size-exclusion separations rather than general analytical HPLC.
- The 1260 Infinity II GPC/SEC System is distinct from the 1260 Amino Acid Analysis System and the 1260 analytical-scale purification system, which target different separation chemistries.
Behavior under load and media
- The detector supports a maximum data acquisition rate of 120 Hz, suitable for narrow GPC/SEC peaks; the 8 signal channels allow simultaneous monitoring of multiple wavelengths or signals.
- The system is rated for a water gradient of 95 (likely % water), indicating compatibility with aqueous SEC modes in addition to organic GPC.
- No digitized curve points were provided, so pressure-flow or calibration behavior cannot be characterized from the available facts.
Installation, control and operation
- Line voltage is 100–240 V at 50 Hz (line frequency), with a maximum motor power of 110 VA; the system weighs 11.5 kg and has a height of 140 mm (width and depth not specified).
- Operating environment: 4–55 °C ambient, up to 95% relative humidity, and up to 3000 m altitude; non-operating temperature range is –40 to 70 °C.
- The brochure digest covers the 1260 Infinity III LC platform but provides no specific installation or control details for this GPC/SEC configuration; the DAD manual digest covers the 1290 Infinity III DAD (G7117A/B/C) and is not directly applicable to this system's detector.
Integration & Operating Notes
The system is rated for 100–240 V at 50 Hz only; operation on a 60 Hz supply is not covered by the verified specifications and may affect pump and detector timing. Confirm site frequency and provide a stable, grounded supply sized for the 110 VA motor power.
The system is rated for 4–55 °C operating ambient and up to 95% relative humidity; exceeding these limits can cause condensation in the detector optics or drift in retention times. If the lab exceeds 3000 m altitude, detector performance may degrade.
The water gradient rating of 95 indicates the system can run aqueous SEC eluents; for organic GPC, ensure solvent compatibility with the deuterium lamp detector flow cell and the 1024-element array. No pressure limit is stated in the verified facts, so consult the pump manual for maximum operating pressure.
The deuterium lamp has a rated operating life of 967 hours; log lamp-on time and schedule replacement before intensity drop affects baseline noise. The detector's 8 signal channels and 120 Hz acquisition rate should be verified after lamp replacement using a reference standard.
Selection & Integration Q&A
Choose this system for polymer molecular-weight distribution by GPC/SEC in organic or aqueous mode, where the 120 Hz acquisition and 8 signal channels resolve narrow peaks. The 1220 Infinity II LC is a compact general HPLC with lower acquisition rates; the 1260 Amino Acid Analysis System is dedicated to amino acid chemistry and not suitable for GPC/SEC.
The deuterium lamp is rated for 967 operating hours; track lamp-on time and replace before intensity falls below acceptable baseline noise. After replacement, verify the 8 signal channels and 120 Hz data acquisition rate with a reference standard. No other maintenance intervals are specified in the verified facts.
The verified facts do not list included accessories or a column oven; the system is described as a GPC/SEC system with a deuterium lamp detector and 1024-element array. Confirm with the vendor whether the flow cell, columns, and solvent delivery modules are part of the base configuration, as these are not specified in the available documentation.