Agilent Technologies 1260 Infinity III SFC System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1260 Infinity III SFC System

Agilent Technologies 1260 Infinity III SFC System — Liquid chromatography with Pumping speed 3×10⁻⁵ m³/h.

The 1260 Infinity III SFC System is a supercritical fluid chromatography platform configured with a 0.5 mL/min pumping module and a 10 mm flow cell. It is the dedicated SFC modification of the SFC Solutions series, positioned alongside the SFC/UHPLC Hybrid System for laboratories that run SFC separations only. It serves as the separation engine in method-development and routine SFC workflows.

Pumping speed
3×10⁻⁵ m³/h

Agilent Technologies 1260 Infinity III Series — Model Comparison & Selection

Model Pumping speed, m³/hColumn particle size, µmFilter membrane pore size, µmFlow cell path length, mmSample volume, milliliterTotal run time, minutes
1260 Infinity III SFC System Current 3×10⁻⁵1.80.2210——
1260 Infinity III SFC/UHPLC Hybrid System 3×10⁻⁵2.70.22100.0045.5

Full specifications

Core Performance & Functional Specifications
Pumping speed 0.5 mL/min
Column Particle Size 1.8 µm
Filter Membrane Pore Size 0.22 µm
Solvent A mfr Water Water
Solvent B mfr ACN ACN
Column dimensions mfr 2.1 mm
Software version mfr 2.8 later
Gradient mfr 5...95
Sample concentration mfr 100 mg/L
Dimensions, Weight & Mechanical Design
Flow Cell Path Length 10 mm
Standards, Safety & General Data
Column part number mfr 959758

Description

Construction and series positioning

Method and media behavior

Control and operation

Integration & Operating Notes

Process Limits
Match column hardware to the 2.1 mm method format

The documented method is built around a 2.1 mm column (part number 959758) with 1.8 µm particles. Substituting a different column format changes the method geometry and is not covered by the supplied facts; verify compatibility before altering the column configuration.

Factory Specification Sheet
Cooling & Media
Filter mobile phases through 0.22 µm membranes

Solvent A is water and solvent B is ACN in the documented method, and the specification calls for 0.22 µm filter membranes. Particulate carryover into a 1.8 µm column bed is the risk this filtration step addresses; the supplied facts do not state a filtration interval.

Factory Specification Sheet
Control & I/O
Software version 2.8 referenced for this method

The method facts reference software version 2.8 or later. The supplied documents do not describe driver, firmware or interface requirements beyond this, so confirm control-software compatibility with the system before commissioning.

Factory Specification Sheet
Maintenance
No service intervals are defined in the supplied documents

The attached technical overviews cover the InfinityLab Sample ID Reader on 1290 Infinity III Multisampler configurations and contain no maintenance schedule, error codes or consumables list for this SFC system. Service planning must come from the instrument manual, which was not provided.

Technical Overview 5994-7568EN / 5994-7569EN

Selection & Integration Q&A

When should I choose the 1260 Infinity III SFC System instead of the SFC/UHPLC Hybrid System?

Choose this system when the workflow is SFC-only; both models share the 0.5 mL/min pumping specification. The Hybrid System is the sibling to select when UHPLC capability must coexist with SFC in the same instrument. The supplied facts give no further differentiators, so confirm detection and column configuration against your method.

What column and mobile-phase preparation does the documented method require?

The method uses a 2.1 mm column (part number 959758) packed with 1.8 µm particles, water as solvent A and ACN as solvent B, run on a 5...95 gradient at 100 mg/L sample concentration. Mobile phases must pass 0.22 µm filter membranes before use.

What mounting, environment or duty-cycle limits apply to this system?

The supplied documents contain no installation, environmental or duty-cycle data for this SFC system; the attached technical overviews address the Sample ID Reader on 1290 Infinity III Multisampler configurations instead. Obtain these limits from the instrument manual before siting the system.

What maintenance schedule and accessories come with the base delivery?

No maintenance intervals, error codes or consumables list are defined in the supplied facts, and no accessories or cables are itemized for the base delivery. The 2.1 mm column (part number 959758) and 0.22 µm filter membranes are method items to specify separately; confirm the delivery scope with the vendor.