Agilent Technologies 1260 Infinity III SFC/UHPLC Hybrid System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1260 Infinity III SFC/UHPLC Hybrid System

Agilent Technologies 1260 Infinity III SFC/UHPLC Hybrid System — Liquid chromatography with Pumping speed 3×10⁻⁵ m³/h.

The 1260 SFC/UHPLC hybrid system combines supercritical fluid chromatography with ultra-high-performance liquid chromatography in a single instrument. It uses a 2.1 mm column with 2.7 µm particles, a 4 µL injection volume, and a 10 mm flow cell, achieving a 5.5-minute total run time. This configuration is suited for rapid method development and orthogonal separations in pharmaceutical and food analysis.

Pumping speed
3×10⁻⁵ m³/h

Agilent Technologies 1260 Infinity III Series — Model Comparison & Selection

Model Pumping speed, m³/hColumn particle size, µmFilter membrane pore size, µmFlow cell path length, mmSample volume, milliliterTotal run time, minutes
1260 Infinity III SFC/UHPLC Hybrid System Current 3×10⁻⁵2.70.22100.0045.5
1260 Infinity III SFC System 3×10⁻⁵1.80.2210——

Full specifications

Core Performance & Functional Specifications
Pumping speed 0.5 mL/min
Column Particle Size 2.7 µm
Filter Membrane Pore Size 0.22 µm
Sample volume 4 µL
Total Run Time 5.5 minutes
BPR pressure mfr 150 bar
Sample concentration mfr 100 mg/L
Flow gradient rate mfr 2.5...4 mL/min
Column dimensions mfr 2.1 mm
Resolution (Rs) mfr 1.69
Solvent A mfr Water Water
Solvent B mfr ACN ACN
Software version mfr 2.8 later
Gradient mfr 5...95
Dimensions, Weight & Mechanical Design
Flow Cell Path Length 10 mm
Peak height increase mfr 37.6 mAu
Standards, Safety & General Data
Column part number mfr 959758

Description

System Architecture and Series Positioning

Separation Behavior and Performance

Installation, Control, and Operation

Integration & Operating Notes

Cooling & Media
CO2 supply must be clean and dry

The SFC control module requires CO2 of at least 4.5 grade purity. Moisture or particulates in the CO2 supply can cause baseline noise, restrictor clogging, or damage to the pump seals. Install a suitable filter and moisture trap in the CO2 line.

Technical Overview 5991 8492EN, Installation Requirements
Control & I/O
Software version 2.8 or later required for hybrid control

The 1260 SFC/UHPLC hybrid system requires Agilent OpenLab CDS or compatible software version 2.8 or later to coordinate SFC and UHPLC modes. Earlier versions may not support the four-column selection valve or the BPR control, leading to communication errors or incomplete method execution.

Technical Overview 5991 8492EN, Software Requirements
Maintenance
Replace filter membrane every 3 months

The 0.22 µm filter membrane in the solvent delivery path should be replaced at least every three months or when backpressure increases by 10 bar. A clogged membrane can cause erratic flow and damage the pump. Use only Agilent-certified replacement membranes.

Technical Overview 5991 8492EN, Maintenance Schedule

Selection & Integration Q&A

When should I choose the 1260 SFC/UHPLC hybrid system over a dedicated 1220 Infinity II LC System?

Choose the hybrid when you need both supercritical fluid chromatography (SFC) and ultra-high-performance liquid chromatography (UHPLC) on one platform, especially for orthogonal separations or rapid method development. The 1220 Infinity II LC System is limited to analytical HPLC and cannot perform SFC. The hybrid also offers higher pressure capability (150 bar BPR) and a four-column selection valve for automated method scouting.

What are the requirements for the CO2 supply and backpressure regulator when integrating this system?

The SFC control module requires CO2 of at least 4.5 grade purity, supplied at a pressure of 5–7 bar. The backpressure regulator must be set to 150 bar and 60 °C to maintain supercritical conditions. Ensure the CO2 line is equipped with a filter and moisture trap. The BPR must be compatible with the flow cell pressure rating and connected downstream of the detector.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve performance curve

Click drawing to inspect vector dimensions

Technical documentation