Agilent Technologies 1260 Infinity III SFC System
Agilent Technologies 1260 Infinity III SFC System — Liquid chromatography with Pumping speed 3×10⁻⁵ m³/h.
The 1260 Infinity III SFC System is a supercritical fluid chromatography platform configured with a 0.5 mL/min pumping module and a 10 mm flow cell. It is the dedicated SFC modification of the SFC Solutions series, positioned alongside the SFC/UHPLC Hybrid System for laboratories that run SFC separations only. It serves as the separation engine in method-development and routine SFC workflows.
Agilent Technologies 1260 Infinity III Series — Model Comparison & Selection
| Model | Pumping speed, m³/h | Column particle size, µm | Filter membrane pore size, µm | Flow cell path length, mm | Sample volume, milliliter | Total run time, minutes |
|---|---|---|---|---|---|---|
| 1260 Infinity III SFC System Current | 3×10⁻⁵ | 1.8 | 0.22 | 10 | — | — |
| 1260 Infinity III SFC/UHPLC Hybrid System | 3×10⁻⁵ | 2.7 | 0.22 | 10 | 0.004 | 5.5 |
Full specifications
| Pumping speed | 0.5 mL/min |
| Column Particle Size | 1.8 µm |
| Filter Membrane Pore Size | 0.22 µm |
| Solvent A mfr | Water Water |
| Solvent B mfr | ACN ACN |
| Column dimensions mfr | 2.1 mm |
| Software version mfr | 2.8 later |
| Gradient mfr | 5...95 |
| Sample concentration mfr | 100 mg/L |
| Flow Cell Path Length | 10 mm |
| Column part number mfr | 959758 |
Description
Construction and series positioning
- Dedicated SFC configuration of the SFC Solutions series; the sibling 1260 Infinity III SFC/UHPLC Hybrid System shares the 0.5 mL/min pumping specification but adds UHPLC capability.
- The 10 mm flow-cell path length defines the detection cell used with this system.
- Column hardware referenced in the method facts is a 2.1 mm column (part number 959758), matched to 1.8 µm particle columns.
Method and media behavior
- Documented method uses water as solvent A and ACN as solvent B with a 5...95 gradient.
- Sample concentration in the demonstrated method is 100 mg/L.
- Solvent lines require 0.22 µm filter membranes; column particle size is 1.8 µm.
Control and operation
- Software version 2.8 or later is referenced for the method context.
- The attached technical overviews concern the InfinityLab Sample ID Reader on 1290 Infinity III Multisampler configurations and do not define operating limits for this SFC system; no installation, connection or control specifics for this model are available in the supplied documents.
Integration & Operating Notes
The documented method is built around a 2.1 mm column (part number 959758) with 1.8 µm particles. Substituting a different column format changes the method geometry and is not covered by the supplied facts; verify compatibility before altering the column configuration.
Solvent A is water and solvent B is ACN in the documented method, and the specification calls for 0.22 µm filter membranes. Particulate carryover into a 1.8 µm column bed is the risk this filtration step addresses; the supplied facts do not state a filtration interval.
The method facts reference software version 2.8 or later. The supplied documents do not describe driver, firmware or interface requirements beyond this, so confirm control-software compatibility with the system before commissioning.
The attached technical overviews cover the InfinityLab Sample ID Reader on 1290 Infinity III Multisampler configurations and contain no maintenance schedule, error codes or consumables list for this SFC system. Service planning must come from the instrument manual, which was not provided.
Selection & Integration Q&A
Choose this system when the workflow is SFC-only; both models share the 0.5 mL/min pumping specification. The Hybrid System is the sibling to select when UHPLC capability must coexist with SFC in the same instrument. The supplied facts give no further differentiators, so confirm detection and column configuration against your method.
The method uses a 2.1 mm column (part number 959758) packed with 1.8 µm particles, water as solvent A and ACN as solvent B, run on a 5...95 gradient at 100 mg/L sample concentration. Mobile phases must pass 0.22 µm filter membranes before use.
The supplied documents contain no installation, environmental or duty-cycle data for this SFC system; the attached technical overviews address the Sample ID Reader on 1290 Infinity III Multisampler configurations instead. Obtain these limits from the instrument manual before siting the system.
No maintenance intervals, error codes or consumables list are defined in the supplied facts, and no accessories or cables are itemized for the base delivery. The 2.1 mm column (part number 959758) and 0.22 µm filter membranes are method items to specify separately; confirm the delivery scope with the vendor.