Agilent Technologies 4150 TapeStationDx

Agilent Technologies 4150 TapeStationDx — Automated electrophoresis.

The 4150 TapeStationDx is a CE-IVD-labeled automated electrophoresis instrument for DNA/RNA sample QC in regulated laboratories. It processes 1–96 samples per run with a 2 µL sample input and a 90-minute run time for 96 samples, using an 8-well strip loading format. It is the lower-throughput sibling of the 4200 TapeStationDx, which is described as the high-throughput variant.

Agilent Technologies Tapestation Instruments Series — Model Comparison & Selection

Model SensitivityDimensions w d hWeight, kgStorage temperature, °CAnalysis time, minApplication
4150 TapeStationDx Current —————automated electrophoresi
4150 TapeStation 525417.8-40...7016—
4200 TapeStation 543525.5-40...7016—
4200 TapeStationDx System —————automated electrophoresi

Full specifications

Core Performance & Functional Specifications
Application automated electrophoresis for QC of DNA and RNA samples isolated from human specimen
Run Time For 96 Samples 90 minutes
Sample Capacity 1...96 samples
Sample Input Volume 2 µL
Time per sample mfr 1...2 minutes
Samples per run mfr 1...96 samples
Sample loading format mfr 8 plate
Analysis time per sample mfr 1...2 minutes
Instrument format mfr compact benchtop benchtop
Regulatory labeling mfr CE-IVD IVD
Compliance support mfr 21 frameworks
throughput (4200) mfr 1...96 samples
throughput (4150) mfr 1...16 samples
time per sample mfr 1...2 minutes

Description

Series positioning

Throughput and run behavior

Documentation scope

Integration & Operating Notes

Process Limits
Plan runs around the 2 µL sample input and 1–96 sample range

Each sample consumes 2 µL, and a run can carry between 1 and 96 samples. Batching below full capacity is permitted, but the 90-minute figure applies to a 96-sample run; smaller batches should be scheduled against the 1–2 minute per-sample figure rather than the full-plate time.

Factory Specification Sheet
Process Limits
Loading format is an 8-well strip, not a full 96-well plate

The verified loading format is an 8-well strip. Labs planning 96-sample runs must account for arranging samples across multiple 8-well strips rather than a single plate, which affects consumable planning and bench workflow.

Factory Specification Sheet
Compliance
Dx labeling targets regulated and clinical laboratory use

The TapeStationDx portfolio document describes the Dx systems as CE-IVD-labeled for DNA/RNA sample QC in clinical and regulated laboratories. Confirm the applicable regulatory status for your jurisdiction before placing the instrument in a diagnostic workflow.

TapeStationDx Portfolio Document, CE-IVD

Selection & Integration Q&A

When should I choose the 4150 TapeStationDx rather than the 4200 TapeStationDx or the non-Dx 4150 TapeStation?

Choose the 4150 TapeStationDx when you need CE-IVD-labeled DNA/RNA sample QC in a regulated or clinical lab at moderate throughput. The 4200 TapeStationDx is described as the high-throughput variant; the non-Dx 4150 TapeStation is listed separately with a 5 ng/µL sensitivity figure.

What sample volume and batch size must adjacent workflow steps accommodate when integrating this instrument?

Upstream steps must deliver 2 µL per sample, and downstream analysis should be planned around batches of 1–96 samples. A full 96-sample run takes 90 minutes, so adjacent steps should be scheduled against that window rather than per-sample timing alone.

What duty-cycle and consumable-format constraints affect bench layout and scheduling?

Runs accept 1–96 samples with 1–2 minutes per sample and 90 minutes for a full 96-sample run. Samples are loaded in an 8-well strip format, so a 96-sample batch requires multiple strips; plan strip handling and bench space accordingly.

What is not covered by the verified documentation regarding maintenance, accessories and service intervals?

The verified facts contain no maintenance schedule, service interval, error-code list, or accessory/cable/consumable delivery list for the 4150 TapeStationDx. These must be obtained from the full instrument manual or Agilent before planning service and consumable procurement.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Clinical NGS Sample QC Solution
Brochure ·2,9 МБ ·8 pp.
View PDF