Agilent Technologies Activated Phycobiliproteins
Agilent Technologies Activated Phycobiliproteins — Biomolecules conjugation synthesis purification.
Activated phycobiliproteins are native or cross-linked phycobiliprotein preparations (RPE, APC, cross-linked APC, C-PC, PerCP) supplied in a chemically activated form for direct covalent conjugation to antibodies, proteins, or other ligands. The tetrameric 52 kDa form carries an excitation maximum at 566 nm and emission maximum at 575 nm, with a specific activity of 14.0 U/mg HABA dye and solubility at 50 mg/mL. This modification is selected when the user performs in-house conjugate synthesis rather than purchasing pre-made streptavidin-phycobiliprotein conjugates.
Agilent Technologies Phycobiliprotein Series — Model Comparison & Selection
| Model | Emission maximum, nm | Excitation maximum, nm | Molecular weight tetramer size, kDa | Solubility concentration, mg/mL | Specific activity haba dye, U/mg |
|---|---|---|---|---|---|
| Activated Phycobiliproteins Current | 575 | 566 | 52 | 50 | 14 |
| Phycobiliproteins | 575 | 566 | 52 | 50 | 14 |
Full specifications
| Emission Maximum | 575 nm |
| Excitation Maximum | 566 nm |
| Solubility Concentration | 50 mg/mL |
| Specific Activity (haba Dye) | 14.0 U/mg |
| Extinction coefficient mfr | 240 |
| PJRS301*; PJRS20; PJRS34 mfr | Large Large |
| PJRS25**; PJRS27 mfr | Medium Medium |
| PJ39S mfr | Small Small |
| Streptavidin-Agarose bead size distribution mfr | 75...300 microns |
| Streptavidin-Agarose pH stability range mfr | 4...11 |
| Streptavidin-Agarose streptavidin content mfr | 1 beads |
| HRP conjugate stabilizer dilution mfr | 1000 fold |
| AP conjugate stabilizer dilution mfr | 1000 fold |
| RPE conjugation kit antibody capacity mfr | 1 mg |
| RPE conjugation kit minimum scale mfr | 50 antibody |
| RPE conjugation time mfr | as little as two hours hours |
| Molecular Weight (tetramer Size) | 52 kDa |
Description
Construction and series positioning
- The activated phycobiliprotein line is a conjugation-ready intermediate, not a finished detection reagent. It sits between the native phycobiliprotein products (RPE, APC, cross-linked APC, C-PC, PerCP) and the streptavidin-phycobiliprotein conjugates (RPE and APC versions, sampler kit) listed in the same Agilent portfolio.
- Sibling products Allophycocyanin (APC) Conjugates and RPE Conjugates are pre-conjugated reagents; the activated phycobiliproteins are the upstream building block for users who attach their own antibody or ligand.
- The tetrameric unit is 52 kDa; excitation maximum 566 nm, emission maximum 575 nm, extinction coefficient 240 (as listed).
Behavior in conjugation chemistry
- Specific activity is stated as 14.0 U/mg HABA dye, the standard streptavidin/biotin-binding activity scale used across the Agilent streptavidin and phycobiliprotein catalog; this value ties the activated preparation to the same activity basis as SA10 native streptavidin and SA26 recombinant streptavidin-plus.
- Solubility is 50 mg/mL, defining the working concentration ceiling for conjugation reactions.
- No digitized curve points are supplied for this model; spectral behavior is given only by the excitation and emission maxima above.
Installation, connection and operation
- The attached document digest covers the broader streptavidin/phycobiliprotein portfolio (SA10, SA26, streptavidin-HRP/AP conjugates and stabilizers, native and cross-linked phycobiliproteins, activated phycobiliproteins and conjugation kits, streptavidin-phycobiliprotein conjugates) but contains no section-level or actionable engineering facts; installation and conjugation protocol specifics must therefore be taken from the full manual, not from this card.
Integration & Operating Notes
The stated solubility of 50 mg/mL is the ceiling for dissolving the activated phycobiliprotein before conjugation; exceeding it risks incomplete dissolution and unreacted activated dye in the final conjugate, which will raise background in the assay.
The excitation maximum is 566 nm and the emission maximum 575 nm; the illumination or laser line and the emission filter set must be chosen around these values, otherwise the 52 kDa tetramer will be poorly excited and the conjugate signal will be weak.
Specific activity is expressed as 14.0 U/mg HABA dye, the same activity scale used for SA10 native streptavidin and SA26 recombinant streptavidin-plus; when qualifying a lot, run the HABA assay on this basis rather than assuming equivalence to other phycobiliprotein lots.
The attached document digest lists the activated phycobiliproteins only as a portfolio item and provides no section-level or actionable engineering facts; the conjugation ratio, buffer and quenching steps must be taken from the full manual or kit instructions, not inferred from this card.
Selection & Integration Q&A
Choose the activated phycobiliprotein when you will attach your own antibody or ligand and need the 566/575 nm tetramer as a building block. Choose RPE Conjugates or Allophycocyanin (APC) Conjugates when a pre-made reagent is acceptable and no in-house conjugation step is wanted.
The 14.0 U/mg HABA dye activity basis is shared with SA10 native streptavidin and SA26 recombinant streptavidin-plus, so streptavidin partners should be qualified on the same HABA scale. The 50 mg/mL solubility sets the working concentration; keep the 52 kDa tetramer within that limit during coupling.
No mounting, environment or duty-cycle limits are stated in the supplied facts; the only operating limits given are the 50 mg/mL solubility and the 566 nm excitation / 575 nm emission maxima. Consult the full manual for storage and handling conditions before use.
The base delivery is the activated phycobiliprotein itself; conjugation kits, streptavidin-HRP/AP conjugates and stabilizers are separate catalog items in the same portfolio. Lot qualification should use the HABA assay at 14.0 U/mg. No service interval is stated in the supplied facts.