Agilent Technologies ADM Flow Meter for gas chromatography (GC)
Agilent Technologies ADM Flow Meter for gas chromatography (GC) — Gas purification gas management.
The Agilent ADM Flow Meter is a handheld, battery-powered (5 V DC, 0.5 A) gas flow meter for GC diagnostics, using a swappable NIST-certified calibration cartridge and a TCD sensor to measure any noncorrosive gas or gas mixture. It records four flows and displays results on an OLED screen. Its interchangeable cartridge design distinguishes it within the CrossLab CS series, where a sibling leak-detector cartridge (hydrogen, nitrogen, helium) can be fitted after a firmware update.
Full specifications
| Sensitivity | 0.003 mL/min |
| Accuracy | 2 greater |
| Dimensions | 201 mm |
| Sensor type mfr | TCD TCD |
| Gases detected mfr | helium, hydrogen, and large nitrogen leaks leaks |
| Power-off method mfr | press and hold Power/Mode button for three secon |
| Cartridge fastening mfr | two captive thumbscrews thumbscrews |
| Measurable gases mfr | any noncorrosive gas, including mixtures of gase |
| Calibration mfr | NIST-certified swappable calibration cartridge c |
| Flow records mfr | four flows flows |
| Adaptor connection mfr | 1 Swagelok |
| Power/Mode button hold time to power down mfr | three seconds seconds |
| Flow range mfr | 0.5...750 ranging |
| flow range mfr | 0.5...750 mL/min |
| Accuracy*: 0.5 to 500 mL/min mfr | 2 greater. |
| Accuracy*: 501 to 750 mL/min mfr | 3 reading |
| Warning indication mfr | 28 |
| Error indication mfr | 28 |
| Power Indications mfr | 30 |
| Installing and Replacing the Cartridge mfr | 31 |
| Installing the cartridge mfr | 31 |
| Swapping or replacing the cartridge with ADM flow meter cartridge mfr | 31 |
| Replacing the Batteries mfr | 33 |
| Upgrading the Firmware/Retrieving Certificate of Calibration mfr | 35 |
| Using the Flow Meter Stand mfr | 36 |
| A Note About Backpressure mfr | 37 |
| Technical Support mfr | 37 |
| Other Features mfr | 37 |
| Safety and Regulatory Certification mfr | 38 |
| Disposal mfr | 38 |
| Accuracy 501 to 750 mL/min mfr | 3 reading |
| Weight | 420 g |
| Power consumption | AA batteries , or USB power |
| Power supply | 5 DC |
| Power supply current mfr | 0.5 A |
| Agilent ADM Flow Meter mfr | 6691 A |
| ADM Flow meter replacement cartridge mfr | 6692 A |
| CrossLab CS Electronic Leak Detector mfr | 6693 A |
| Electronic leak detector cartridge only mfr | 6694 A |
| Low battery indication mfr | 29 |
| Firmware upgrade interface mfr | USB connection to computer computer |
| Display mfr | 128 scales |
| Class A EMC certification mfr | 38 |
Description
Construction and series positioning
- Handheld instrument with a large OLED display and a kickstand for bench use.
- The measurement element is a user-swappable calibration cartridge, fastened with two captive thumbscrews; each cartridge is NIST-certified.
- Within the CrossLab CS cartridge system, this flow-meter cartridge is the flow-measurement configuration; the sibling leak-detector cartridge (for hydrogen, nitrogen and large helium leaks) is a different function and can be used in the same meter body only after a firmware update.
- Firmware updates are performed over USB.
Measurement behavior
- The TCD sensor measures flow of any noncorrosive gas, including mixtures; no curve points or flow ranges are stated in the verified facts, so no turndown or accuracy figures are asserted here.
- The meter stores four flow records for later review on the OLED screen.
- Gas-specific calibration is carried by the cartridge, not by the meter body; changing the measured gas means changing the cartridge.
Power, control and connection
- Powered from a 5 V DC supply drawing 0.5 A.
- Power-off is a deliberate action: press and hold the Power/Mode button for three seconds.
- A 1/8" Swagelok adaptor is listed among the connection accessories.
- No installation, environmental or maintenance procedures are present in the supplied document digests; those details must be taken from the full user manual (G6691-90000).
Integration & Operating Notes
The TCD sensor is specified for any noncorrosive gas, including mixtures. Corrosive or reactive gases must not be introduced, as they can attack the sensor and cartridge and invalidate the NIST-traceable calibration.
Calibration is held in the NIST-certified cartridge, which is removed and replaced using the two captive thumbscrews. Keep the cartridge clean and store it protected; a damaged or contaminated cartridge compromises measurement traceability and must be replaced rather than recalibrated in place.
Selection & Integration Q&A
Choose the flow-meter cartridge when the task is measuring flow of noncorrosive gases or mixtures and recording up to four flows. Choose the leak-detector cartridge (hydrogen, nitrogen, large helium leaks) when the task is leak location; it fits the same meter only after a USB firmware update.
The supplied document digests contain no environmental or duty-cycle specifications. Consult the full ADM Flow Meter user manual (G6691-90000) for operating temperature, humidity and continuous-use limits before deploying the meter in a GC system environment.
The NIST-certified calibration cartridge is the calibration consumable and is replaced via the two captive thumbscrews. A USB cable is needed for firmware updates, and a 1/8" Swagelok adaptor is listed for connection. No service interval is stated in the verified facts; follow the user manual.