Agilent Technologies Cary 60 Fiber Optic UV Dissolution System
Agilent Technologies Cary 60 Fiber Optic UV Dissolution System — Dissolution testing.
The Cary 60 Fiber Optic UV Dissolution System is an online dissolution testing configuration that uses in situ fiber optic probes and a multiplexer with the Cary 60 UV-Vis spectrophotometer. It supports 1 to 2 dissolution apparatus and covers a 190 nm wavelength range with 1.5 nm slit width. It is distinguished from the Multicell sibling by probe-based, pump-free sampling for real-time in situ measurement.
Agilent Technologies Cary Series — Model Comparison & Selection
| Model | Wavelength range | Baseline flatness | Photometric accuracy | Slit width, nm |
|---|---|---|---|---|
| Cary 60 Fiber Optic UV Dissolution System Current | 190 | 1 | 0.005 | 1.5 |
| Cary 60 Multicell UV Dissolution System | 190 | 1 | 0.005 | 1.5 |
Full specifications
| Wavelength range | 190 nm |
| Baseline Flatness | 0.001 Abs |
| Photometric accuracy | 0.005 Abs |
| Software package mfr | Cary WinUV WinUV |
| Number of apparatus mfr | 1...2 |
| Lamp type mfr | Xenon flash flash |
| Instrument design mfr | Scanning Scanning |
| Wavelength accuracy mfr | 0.5 nm |
| Wavelength reproducibility mfr | 0.1 nm |
| Stray light mfr | 1.0 |
| Path lengths mfr | 0.2 mm |
| Closed loop sampling mfr | Yes Yes |
| Path lengths (mm) mfr | 0.2 |
| Automated dosage delivery mfr | Yes Yes |
| Sampling mfr | Simultaneous Simultaneous |
| Sample filtration (min. pore size μm) mfr | 0.2 μm |
| Sample archival mfr | Yes Yes |
| minimum reading interval mfr | 45 seconds |
| lamp lifetime mfr | 10 years |
| photometric linear range mfr | 3.5 Abs |
| Slit Width | 1.5 nm |
| path length (multicell) mfr | 0.2...10 mm |
| path length (fiber optic tips) mfr | 1...20 mm |
| Photometric noise mfr | 0.0001 Abs |
Description
Construction and series positioning
- The Fiber Optic configuration pairs the Cary 60 scanning UV-Vis spectrophotometer with a fiber optic multiplexer and in situ probes; the Multicell sibling instead uses a multicell changer with peristaltic pump or 850-DS Sampling Station.
- Both configurations share the Cary WinUV software package and support 1 to 2 dissolution apparatus.
- The xenon flash lamp source and scanning design are common to the Cary 60 platform.
Optical performance
- Wavelength range starts at 190 nm; slit width is 1.5 nm.
- Wavelength accuracy is 0.5 nm and reproducibility 0.1 nm.
- Photometric accuracy is 0.005 Abs, baseline flatness 0.001 Abs, and photometric noise 0.0001 Abs.
- Stray light is specified as 1.0 (unit not stated in the source).
Operation and integration
- In situ fiber optic probes eliminate the need for a peristaltic pump in the sampling path, enabling real-time measurement directly in the vessel.
- The system is controlled through Cary WinUV software; no further control or I/O details are provided in the available digest.
Integration & Operating Notes
The system is operated through the Cary WinUV software package. No additional controller, cable, or interface specifications are provided in the available document digest; verify PC and interface requirements against the full manual.
Selection & Integration Q&A
Choose Fiber Optic when you need in situ measurement with fiber optic probes and a multiplexer, avoiding pump-based sampling. Choose Multicell when your workflow requires a multicell changer with peristaltic pump or 850-DS Sampling Station. Both support 1 to 2 apparatus and share Cary WinUV software.
The Fiber Optic configuration requires the Cary 60 UV-Vis spectrophotometer, a fiber optic multiplexer, and in situ fiber optic probes, all controlled by Cary WinUV software. No pump is used in this configuration. Confirm probe compatibility and multiplexer channel count against your apparatus count (1 to 2).
The available document digest does not specify mounting, environmental, or duty-cycle limits for this configuration. Consult the full Cary 60 UV-Vis and dissolution system manuals for installation clearances, temperature/humidity ranges, and duty-cycle guidance before site planning.
The digest does not list maintenance intervals or included accessories. Fiber optic probes and multiplexer are configuration-defining and should be confirmed in the order. Replacement probes, cables, and the Cary WinUV software license should be verified against the quotation; no service schedule is provided in the available facts.