Agilent Technologies Cary 60 Multicell UV Dissolution System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Cary 60 Multicell UV Dissolution System

Agilent Technologies Cary 60 Multicell UV Dissolution System — Dissolution testing.

The Cary 60 Multicell UV Dissolution System is an online scanning UV-Vis system built around the Cary 60 spectrophotometer, a multicell changer, and Cary WinUV software. It supports 1 to 2 dissolution apparatus and uses a xenon flash lamp with a 190 nm wavelength range. This modification is distinguished from the Fiber Optic sibling by its multicell changer and peristaltic pump or 850-DS Sampling Station, serving automated dissolution testing.

Agilent Technologies Cary Series — Model Comparison & Selection

Model Wavelength rangeBaseline flatnessPhotometric accuracySlit width, nm
Cary 60 Multicell UV Dissolution System Current 19010.0051.5
Cary 60 Fiber Optic UV Dissolution System 19010.0051.5

Full specifications

Core Performance & Functional Specifications
Wavelength range 190 nm
Baseline Flatness 0.001 Abs
Photometric accuracy 0.005 Abs
Software package mfr Cary WinUV WinUV
Number of apparatus mfr 1...2
Lamp type mfr Xenon flash flash
Instrument design mfr Scanning Scanning
Wavelength accuracy mfr 0.5 nm
Wavelength reproducibility mfr 0.1 nm
Stray light mfr 1.0
Path lengths mfr 0.2 mm
Closed loop sampling mfr Yes Yes
Path lengths (mm) mfr 0.2
Automated dosage delivery mfr Yes Yes
Sampling mfr Simultaneous Simultaneous
Sample filtration (min. pore size μm) mfr 0.2 μm
Sample archival mfr Yes Yes
minimum reading interval mfr 45 seconds
lamp lifetime mfr 10 years
photometric linear range mfr 3.5 Abs
Dimensions, Weight & Mechanical Design
Slit Width 1.5 nm
path length (multicell) mfr 0.2...10 mm
path length (fiber optic tips) mfr 1...20 mm
Operating Conditions, Environment & Protection
Photometric noise mfr 0.0001 Abs

Description

Construction and series positioning

The Cary 60 Multicell UV Dissolution System is one of two online configurations in the Agilent Cary 60 UV Dissolution series. It pairs the Cary 60 UV-Vis scanning spectrophotometer with a multicell changer and either a peristaltic pump or an 850-DS Sampling Station. The sibling Fiber Optic system instead uses a fiber optic multiplexer with in situ probes. Both configurations share the Cary 60 spectrophotometer and Cary WinUV software and support 1 to 2 dissolution apparatus. The Multicell version is therefore the choice when samples are to be transferred from vessels to a flow-through cell for measurement, rather than measured in situ.

Optical and measurement behavior

The spectrophotometer is a scanning instrument with a xenon flash lamp and a 1.5 nm slit width. Its specified wavelength range starts at 190 nm. Wavelength accuracy is 0.5 nm and wavelength reproducibility 0.1 nm. Photometric accuracy is 0.005 Abs, photometric noise 0.0001 Abs, and baseline flatness 0.001 Abs. Stray light is given as 1.0. These performance figures apply to the Cary 60 spectrophotometer common to both online configurations; no curve points or media-specific behavior are provided in the verified facts.

Installation, connection and control

The system is controlled through the Cary WinUV software package. The multicell configuration requires either a peristaltic pump or an 850-DS Sampling Station to move sample from the dissolution apparatus to the multicell changer. The verified facts do not include electrical ratings, interface details, or installation procedures; these must be taken from the instrument manuals rather than inferred here.

Integration & Operating Notes

Process Limits
Sample transfer hardware must be selected before ordering

The Multicell configuration requires either a peristaltic pump or an 850-DS Sampling Station to deliver sample from the dissolution vessel to the multicell changer. The choice determines tubing, pump control and sampling sequence, so it must be fixed at the system configuration stage rather than added later.

Brochure Online UV-Vis Dissolution Systems Cary 60 5991-4048EN, Scope and Variants
Control & I/O
Operation and data handling run through Cary WinUV software

The system is driven by the Cary WinUV software package, which is common to both the Multicell and Fiber Optic online configurations. Method setup, scanning and result handling are performed in this environment; the verified facts do not list separate controller hardware or third-party software interfaces.

Brochure Online UV-Vis Dissolution Systems Cary 60 5991-4048EN, Scope and Variants
Process Limits
System supports one or two dissolution apparatus only

The online system is specified for 1 to 2 dissolution apparatus. Configurations requiring more than two vessels or apparatus must be split across additional systems; the verified facts give no provision for extending a single system beyond two apparatus.

Brochure Online UV-Vis Dissolution Systems Cary 60 5991-4048EN, Scope and Variants
Maintenance
Lamp is xenon flash, not a conventional deuterium lamp

The spectrophotometer uses a xenon flash lamp. The verified facts do not state a lamp replacement interval, warm-up requirement or lamp-life figure, so maintenance planning for the source should follow the Cary 60 spectrophotometer documentation rather than assumptions carried over from deuterium-lamp instruments.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the Cary 60 Multicell system instead of the Fiber Optic sibling?

Choose Multicell when sample is to be pumped from vessels to a multicell changer via a peristaltic pump or 850-DS Sampling Station. Choose the Fiber Optic sibling when in situ measurement with a fiber optic multiplexer and probes is preferred. Both share the Cary 60 spectrophotometer and WinUV software and support 1 to 2 apparatus.

What adjacent hardware must be specified with the Multicell system for sample handling?

The Multicell configuration requires either a peristaltic pump or an 850-DS Sampling Station to transfer sample to the multicell changer. This choice determines the tubing and sampling sequence and should be fixed when the system is configured, since the two options are not interchangeable after delivery.

What are the mounting and duty-cycle limits for this system?

The verified facts do not specify mounting clearances, environmental ranges or duty-cycle limits for the Multicell system. These must be taken from the Cary 60 spectrophotometer and multicell changer manuals. The only stated capacity limit is support for 1 to 2 dissolution apparatus per system.

What maintenance and consumables are not included in the base delivery?

The verified facts list no maintenance schedule, service intervals, cables or consumables in the base delivery. The xenon flash lamp is the source, but no replacement interval is stated. Pump tubing for the peristaltic pump or 850-DS Sampling Station and any probe or cell accessories should be confirmed against the order configuration.