No photo available yet
Agilent Technologies Take gene expression to the next level, Custom Exon Microarrays
Agilent Technologies Take gene expression to the next level, Custom Exon Microarrays — Gene expression microarray platform.
Custom Exon Microarrays are a one-color or two-color 60-mer oligonucleotide array platform for exon-level expression profiling from 25–100 ng total RNA using Low Input Quick Amp WT labeling. This custom modification differs from the series' gene-expression and yeast arrays by exon-level probe content and a defined spike-mix workflow. It serves transcriptome-wide exon analysis in a microarray hybridization system.
Agilent Technologies Custom Microarrays Series — Model Comparison & Selection
| Model | Total rna input, ng | Total rna input highest listed, ng | Total rna input lowest listed, ng | Cdna synthesis incubation, °C | Cdna synthesis incubation time, hours | Crna elution volume, microliter |
|---|---|---|---|---|---|---|
| Take gene expression to the next level, Custom Exon Microarrays Current | 25 | 100 | 25 | 40 | 2 | 30 |
| Custom Gene Expression Microarray | 10...200 | 200 | 10 | 40 | 2 | 30 |
Full specifications
| Cdna Synthesis Incubation Time | 2 hours |
| Crna Elution Volume | 30 µL |
| Crna Transcription Incubation Time | 2 hours |
| Enzyme Inactivation Time | 15 minutes |
| Fragmentation Incubation Time | 30 minutes |
| Hybridization Duration | 17 hours |
| Hybridization Rotator Speed | 10 rpm |
| Hybridization Time | 17 hours |
| Hybridization Volume | 490 µL |
| Maximum Total Rna Sample Volume | 2.3 µL |
| Minimum Pipette Dispensing Volume | 2 µL |
| Pipetting volume | 2 µL |
| Primer/template Denaturation Time | 10 minutes |
| Recommended Crna Yield | 5 µg |
| Spike Mix Heat Incubation Time | 5 minutes |
| Spike Mix Volume Per Labeling Reaction | 2 µL |
| Starting Total Rna Amount | 25 ng |
| Step 1 Time Required | 0.5 hours |
| Total Rna Input | 25 ng |
| Total Rna Input, Highest Listed | 100 ng |
| Total Rna Input, Lowest Listed | 25 ng |
| Total Volume | 3 |
| Triton X-102 Final Concentration In Wash Buffers | 0.005 % |
| Minimum Feature Extraction software version for automatic eArray download mfr | 10.7 |
| Spike A Mix labeling dye mfr | 3 |
| Feature Extraction Software version for SpikeIns LogRatio Statistics mfr | 10.7.3 later |
| Feature Extraction software version mfr | 10.7 higher |
| Specific activity mfr | 15 cRNA |
| Recommended specific activity mfr | 15 cRNA |
| Agilent Microarray Scanner mfr | 4900 BA |
| Hybridization gasket slides 1 microarray/slide, 5 slides/box mfr | 2534 |
| Hybridization gasket slides 2 microarrays/slide, 5 slides/box mfr | 2534 |
| Hybridization gasket slides 4 microarrays/slide, 5 slides/box mfr | 2534 |
| Hybridization gasket slides 8 microarrays/slide, 5 slides/box mfr | 2534 |
| G4832A mfr | 3 Kit |
| G4857A-028679 mfr | 3 Microarray |
| G4848A mfr | 3 Kit |
| G4856A-028680 mfr | 3 Microarray |
| RNA 6000 Nano Assay Kit (RNA Series II Kit) mfr | 5067 |
| Stabilization and Drying Solution* mfr | 5185 |
| Ozone-Barrier Slide Cover* mfr | 2505 |
| Absolutely RNA Nanoprep Kit mfr | 400753 |
| slide box mfr | 07201629 |
| acetonitrile mfr | 271004 L |
| sulfolane mfr | 22209 |
| thermal cycler mfr | 96 tubes |
| Hybridization oven rotator for Agilent Microarray Hybridization Chambers mfr | 2530 |
| nuclease-free 1.5 mL microfuge tube mfr | 12400 equivalent |
| magnetic stir bar (×2) mfr | 401435 equivalent |
| magnetic stir plate (×2) mfr | 6795 equivalent |
| circulating water baths or heat blocks set to 37°C, 40°C, 60°C, 65°C, 70°C, and 80°C mfr | 6795 equivalent |
| microcentrifuge mfr | 5417 equivalent |
| sterile storage bottle mfr | 455 equivalent |
| spectrophotometer mfr | -1000 equivalent |
| micropipettor mfr | -10 equivalent |
| slide-staining dish, with slide rack (×3) mfr | 121 equivalent |
| vacuum concentrator mfr | 120 equivalent |
| RNA 6000 Nano LabChip Kit mfr | 5067 |
| RNA 6000 Pico LabChip Kit mfr | 5067 |
| Spectrophotometer mfr | -1000 equivalent |
| Universal Human Reference RNA mfr | 740000 |
| Universal Mouse Reference RNA mfr | 740100 |
| Universal Rat Reference RNA mfr | 740200 |
| Low Input Quick Amp WT Labeling Kit, One-Color mfr | 5190 |
| RNA Spike-In Kit, One-Color mfr | 5188 |
| Gene Expression Hybridization Kit mfr | 5188 |
| Gene Expression Wash Buffer Kit mfr | 5188 |
| DNase/RNase-free distilled water mfr | 10977 |
| RNeasy Mini Kit mfr | 74104 |
| ethanol (95% to 100% molecular biology grade) mfr | 7023 ML |
| Affinity Script RNase Block Mix (violet cap) mfr | 1.2 |
| Recommended total RNA input (2-, 4-, 8-pack) mfr | 50 ng |
| Prewarm duration for 5× First Strand Buffer mfr | 3...4 minutes |
| Triton X-102 (10%) volume added to wash buffer cubitainer mfr | 2 mL |
| Wash 2 duration mfr | 1 minute |
| Wash 1 duration mfr | 1 minute |
| Thermocycler Program 1 initial denaturation duration mfr | 10 minutes |
| Thermocycler Program 2 incubation duration mfr | 2 hours |
| Thermocycler Program 2 inactivation duration mfr | 15 minutes |
| Labeled cRNA expected size range lower bound mfr | 200 nucleotides |
| Low Input Quick Amp WT Labeling Kit, Two-Color mfr | 5190 |
| RNA Spike-In Kit, Two-Color mfr | 5188 |
| minimum labeled cRNA per microarray mfr | 1.65 μg |
| ozone robustness level mfr | 5 ppb |
| thermocycler program 1 time mfr | 10 minutes |
| thermocycler program 2 time mfr | 2 hours |
| thermocycler program 2 second time mfr | 15 minutes |
| thermocycler hold time mfr | 5 minutes |
| cRNA size range lower bound mfr | 200 nucleotides |
| Hybridization Chamber, stainless mfr | 2534 A |
| Spike A Mix serial dilution (first) mfr | 1 |
| Spike A Mix serial dilution (second) mfr | 1 |
| Spike A Mix serial dilution (third) mfr | 1 |
| Spike A Mix serial dilution (fourth) mfr | 1 |
| Serial dilution first mfr | 1 |
| Serial dilution second mfr | 1 |
| Serial dilution third mfr | 1 |
| Serial dilution fourth mfr | 1 |
| Cdna Synthesis Incubation | 40 °C |
| Crna Transcription Incubation Temperature | 40 °C |
| Enzyme Inactivation Temperature | 70 °C |
| First Strand Buffer Prewarm Temperature | 80 °C |
| Fragmentation Incubation | 60 °C |
| Hybridization Temperature | 65 °C |
| Spike Mix Heat Incubation Temperature | 37 °C |
| Spike Mix Heating Temperature | 37 °C |
| Storage Temperature Of 10× Blocking Agent | -20 °C |
| Storage Temperature Of Total Rna >100 Ng/µl | -80 °C |
| T7 Primer Denaturation Temperature | 65 °C |
| Wash Buffer 2 Prewarm Temperature | 37 °C |
Description
Construction and series positioning
- Custom Exon Microarrays are a custom-content microarray modification within Agilent's gene-expression array series; sibling custom gene-expression and yeast arrays target different probe content.
- The workflow is documented for both one-color (G4140-90042) and two-color (G4140-90052) Low Input Quick Amp WT labeling protocols, version 2.0, August 2015.
- Exon-level analysis is the distinguishing scope of this modification; the series siblings do not carry exon probe content.
Working range and sample behavior
- Total RNA input spans 25 ng to 100 ng; the two-color protocol defines spike dilution schemes for 25, 50, and 100 ng inputs.
- Spike Mix is heated at 37 °C for 5 minutes and dispensed at 2 µL per labeling reaction; minimum pipette dispensing volume is 2 µL.
- A water bath equilibration temperature of 80 °C is specified in the protocol.
- Step 1 (spike mix preparation) requires 0.5 hours.
Data extraction and control
- Feature Extraction software version 10.7 or higher is required for automatic eArray download; version 10.7.3 or later is needed for SpikeIns LogRatio Statistics.
- Spike A Mix and Spike B Mix are labeled with dyes 3 and 5 respectively in the two-color workflow.
Integration & Operating Notes
Automatic eArray download during data extraction requires Feature Extraction software version 10.7 or higher. SpikeIns LogRatio Statistics require version 10.7.3 or later; running an older build blocks these outputs.
Selection & Integration Q&A
Pick the exon array when the experiment requires exon-level resolution across a custom probe set. Choose the custom gene-expression array for gene-level custom content, or the yeast array for yeast transcriptome work; probe content, not hardware, is the differentiator.
Feature Extraction 10.7 or higher is needed for automatic eArray download, and 10.7.3+ for SpikeIns LogRatio Statistics. Labeling follows Low Input Quick Amp WT with 25–100 ng total RNA and 2 µL Spike Mix per reaction.
The array delivery covers the microarray and protocol only. Low Input Quick Amp WT labeling reagents, Spike A/B Mix components, hybridization and wash buffers are separate consumables required to complete the one- or two-color workflow.