Agilent Technologies Benchtop FTIR Instruments
Agilent Technologies Benchtop FTIR Instruments — Molecular spectroscopy.
The Agilent 4200 FlexScan is a handheld FTIR spectrometer for onsite molecular analysis, covering 5100–600 cm⁻¹ with a single-reflection ATR interface (2.6 µm effective pathlength, 2.5 mm surface). Its 3.8 kg weight and 20 cm bench footprint distinguish it from benchtop siblings in the series. It is used for rapid, non-destructive identification of liquids and solids directly in the field.
Agilent Technologies FTIR Spectroscopy Series — Model Comparison & Selection
| Model | Wavelength range | Sample volume, milliliter | Atr path length, µm | Atr surface diameter, mm | Effective pathlength, µm | Optical aperture, mm |
|---|---|---|---|---|---|---|
| Benchtop FTIR Instruments Current | 5100...600 | 0.02 | 2.6 | 2.5 | 2.6 | 25 |
| Compact & Portable FTIR Systems, Mobile FTIR | 5100...600 | 0.02 | 2.6 | 2.5 | 2.6 | 25 |
| FTIR Microscopes & Imaging Systems | 5100...600 | 0.02 | 2.6 | 2.5 | 2.6 | 25 |
Full specifications
| Wavelength range | 5100...600 |
| Atr Surface Diameter | 2.5 mm |
| Effective Pathlength | 2.6 μm |
| Optical Aperture | 25 mm |
| Sample volume | 20 µL |
| Bench space required mfr | 20 cm |
| ATR spectral range mfr | 5100...600 |
| Spectrometer Body mfr | Glass-fiber reinforced polyamide for durability |
| Detector mfr | High-sensitivity thermoelectrically cooled deute |
| Interferometer mfr | 45 aperture |
| Bench space mfr | 20 cm |
| Spectral range (KBr optics) mfr | 7000...350 |
| Spectral range (ZnSe optics) mfr | 5100...600 |
| DialPath path lengths mfr | 30...1,000 microns |
| DialPath Modules mfr | 5100...600 |
| Sample Type mfr | Lower-concentration components, more dilute solu |
| ZnSe engine spectral range mfr | 5100...600 |
| KBr engine spectral range mfr | 7000...350 |
| DialPath pathlength repeatability mfr | 0.25 μm |
| DialPath custom pathlength mfr | 1000 μm |
| TumblIR fixed pathlength range mfr | 100 μm |
| Atr Path Length | 2.6 μm |
| Weight | 3.8 kg |
| Weight range | 3.5 kg |
| ATR effective path length mfr | 36.5 |
| Footprint mfr | 26.4 module |
| ATR effective pH range mfr | 1...14 |
| ATR pH range mfr | 5...9 |
| ZnSe ATR pH range mfr | 5...9 |
Description
Construction and series positioning
The 4200 FlexScan is the handheld FTIR variant in Agilent's onsite-analysis line, weighing 3.8 kg and requiring 20 cm of bench space when docked. Within the series, the 4300 handheld, 4500 portable, and 5500 compact models occupy adjacent positions; the 4200 is the base handheld configuration with a fixed single-reflection ATR interface. Unlike the benchtop Cary 635, which accepts interchangeable ZnSe, Ge, diamond, DialPath, TumblIR, and reflectance modules, the 4200's sampling interface is integral and not user-swappable.
Optical and sampling behavior
The spectrometer covers 5100–600 cm⁻¹. The ATR element provides a 2.6 µm effective pathlength and a 2.5 mm surface diameter, with a 25 mm optical aperture and a 20 µL sample volume. The ATR is rated for pH 5–9; strongly acidic or alkaline samples outside this window will attack the crystal. No digitized curve points were supplied, so spectral resolution and scan-speed behavior cannot be stated.
Installation and operation
No electrical, interface, or control specifications were provided in the verified facts, and the attached document digests contain no actionable engineering facts. Installation, power, and connectivity requirements must therefore be taken from the instrument's own manual rather than inferred here.
Integration & Operating Notes
The ATR element is rated for pH 5–9. Samples outside this range, including strong acids and bases, can corrode or etch the crystal surface, permanently degrading throughput and requiring factory replacement. Neutralize or dilute aggressive samples before measurement.
The ATR surface is 2.5 mm in diameter with a 2.6 µm effective pathlength. The sample must form a continuous film over the entire 2.5 mm surface; insufficient volume or poor contact produces weak or distorted spectra. Ensure the liquid wets the crystal fully before scanning.
Residues left on the 2.5 mm ATR surface contaminate subsequent spectra and can attack the crystal if corrosive. Wipe the crystal with a suitable solvent and dry it between measurements; inspect for scratches or clouding that would reduce effective pathlength.
Selection & Integration Q&A
Choose the 4200 when onsite, hand-carried ATR identification is the primary task and the fixed single-reflection ATR (2.6 µm pathlength, pH 5–9) suits your samples. The 4300, 4500, and 5500 occupy other positions in the series; their specifications are not given here, so compare their sampling interfaces and portability against your sample types before deciding.
The ATR is integral, so no interchangeable module is required. Samples must be compatible with the crystal's pH 5–9 rating and must wet the 2.5 mm surface with roughly 20 µL. No electrical, interface, or controller specifications were provided, so power and data-connection requirements must be confirmed from the instrument manual.
Routine maintenance is cleaning the ATR crystal after each sample to avoid carryover and crystal damage. No accessories, cables, calibration standards, or consumables are listed in the verified facts, so the base-delivery contents and any service intervals must be confirmed with Agilent; do not assume a calibration kit is included.