Agilent Technologies FTIR Microscopes & Imaging Systems

Agilent Technologies FTIR Microscopes & Imaging Systems — Molecular spectroscopy.

The 4200 FlexScan is a handheld FTIR spectrometer for onsite molecular analysis, covering 5100–600 cm⁻¹ with a 2.5 mm ATR surface and 2.6 µm effective pathlength. Its 3.8 kg housing and 20 cm bench footprint distinguish it from the larger 4300, 4500 and 5500 siblings. It is used for direct-contact identification of liquids and solids in the field.

Agilent Technologies FTIR Spectroscopy Series — Model Comparison & Selection

Model Wavelength rangeSample volume, milliliterAtr path length, µmAtr surface diameter, mmEffective pathlength, µmOptical aperture, mm
FTIR Microscopes & Imaging Systems Current 5100...6000.022.62.52.625
Benchtop FTIR Instruments 5100...6000.022.62.52.625
Compact & Portable FTIR Systems, Mobile FTIR 5100...6000.022.62.52.625

Full specifications

Core Performance & Functional Specifications
Wavelength range 5100...600
Atr Surface Diameter 2.5 mm
Effective Pathlength 2.6 μm
Optical Aperture 25 mm
Sample volume 20 µL
Bench space required mfr 20 cm
ATR spectral range mfr 5100...600
Spectrometer Body mfr Glass-fiber reinforced polyamide for durability
Detector mfr High-sensitivity thermoelectrically cooled deute
Interferometer mfr 45 aperture
Bench space mfr 20 cm
Spectral range (KBr optics) mfr 7000...350
Spectral range (ZnSe optics) mfr 5100...600
DialPath path lengths mfr 30...1,000 microns
DialPath Modules mfr 5100...600
Sample Type mfr Lower-concentration components, more dilute solu
ZnSe engine spectral range mfr 5100...600
KBr engine spectral range mfr 7000...350
DialPath pathlength repeatability mfr 0.25 μm
DialPath custom pathlength mfr 1000 μm
TumblIR fixed pathlength range mfr 100 μm
Dimensions, Weight & Mechanical Design
Atr Path Length 2.6 μm
Weight 3.8 kg
Weight range 3.5 kg
ATR effective path length mfr 36.5
Footprint mfr 26.4 module
Materials, Media & Process Compatibility
ATR effective pH range mfr 1...14
ATR pH range mfr 5...9
ZnSe ATR pH range mfr 5...9

Description

Construction and series positioning

Sampling behavior

Installation and operation

Integration & Operating Notes

Process Limits
Keep sample pH within 5–9 at the ATR crystal

The ATR accessory is rated for an effective pH range of 5 to 9. Samples outside this window can attack the crystal or coating, degrading the 2.6 µm effective pathlength and invalidating subsequent spectra; neutralize or use an alternative sampling interface.

Factory Specification Sheet, extra specs: ATR effective pH range
Process Limits
Plan for 20 µL minimum sample on a 2.5 mm ATR spot

The 2.5 mm ATR surface diameter and 20 µL sample volume define the contact area that must be fully wetted for a representative spectrum. Underfilling or spreading the sample beyond the crystal reduces signal and repeatability.

Factory Specification Sheet, matched specs: atr-surface-diameter, sample_volume
Mounting
Allow 20 cm of bench space when docked

The instrument requires 20 cm of bench space in its docked/bench configuration. In handheld use the 3.8 kg mass must be supported during contact measurement; plan a stable surface or stand for repeatable ATR pressure.

Factory Specification Sheet, extra specs: Bench space required; matched specs: weight
Maintenance
Inspect the ATR crystal after every abrasive or high-pH sample

Because the ATR crystal is the exposed optical interface, clean it after each measurement and inspect for scratches or chemical attack, particularly after samples near the pH 5–9 limits. No service interval is stated in the supplied documents.

Factory Specification Sheet, extra specs: ATR effective pH range

Selection & Integration Q&A

When should I choose the 4200 FlexScan instead of the 4300, 4500 or 5500 siblings?

Pick the 4200 when handheld, direct-contact ATR identification at 5100–600 cm⁻¹ is the task and 3.8 kg portability matters. The 4300 handheld, 4500 portable and 5500 compact benchtop are the neighboring options; no comparative specs for them were supplied, so confirm their ranges and interfaces before substituting.

What sample-interface requirements must adjacent equipment meet for this ATR handheld?

The ATR presents a 2.5 mm surface with 2.6 µm effective pathlength and 20 µL sample volume, and tolerates pH 5–9 only. Any sample preparation or delivery hardware must present liquid or solid contact within that spot size and chemistry; no drive, power supply or controller interface data was supplied for this model.

What mounting and duty-cycle limits apply in field use?

The unit weighs 3.8 kg and needs 20 cm of bench space when docked. The supplied documents cover the Cary 635 benchtop, not this handheld, so no duty-cycle, IP rating or environmental limits can be quoted; confirm these with Agilent before continuous field deployment.

What maintenance and accessories are needed beyond the base instrument?

No accessories, cables or consumables are listed in the supplied facts, and no service interval is stated. The only maintenance-relevant fact is the ATR pH 5–9 window, so crystal cleaning and inspection after each sample should be planned; request the accessory and spares list from Agilent.