Agilent Technologies HPLC/UHPLC Upgrades – Upgrade an existing HPLC system
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies HPLC/UHPLC Upgrades – Upgrade an existing HPLC system

Agilent Technologies HPLC/UHPLC Upgrades – Upgrade an existing HPLC system — Liquid chromatography.

The 1260 Infinity II GPC/SEC System is a high-performance gel-permeation/size-exclusion chromatography platform built from InfinityLab LC modules. This card covers the upgrade and supply ecosystem for the series, including 800 bar Quick Turn fittings, 200 mL/min pump heads, and 0.2 µm/47 mm filtration consumables. It is used to configure and maintain GPC/SEC workflows across 1220/1260/1290 Infinity II/III instruments.

Agilent Technologies Liquid Chromatography Series — Model Comparison & Selection

Model Carryover, %Column inner diameter, mmFilter membrane diameter, mmFilter membrane pore size, µmFilter pore size, µmPtfe frits per pm kit, pk
HPLC/UHPLC Upgrades – Upgrade an existing HPLC system Current ——470.225
HPLC Instruments, UHPLC Systems, 9×10⁻⁴4.6————

Full specifications

Core Performance & Functional Specifications
Filter Membrane Diameter 47 mm
Filter Membrane Pore Size 0.2 μm
Filter Pore Size 2 μm
Ptfe Frits Per Pm Kit 5 pk
Pump Head Flow Rate 200 mL/min
Solvent Bottle Volume 1 L
Solvent Filtration Assembly Flask Volume 1 L
Solvent Filtration Assembly Funnel Volume 250 mL
Solvent Inlet Filter Pore Size 10 μm
Well-plate Closing Mat Quantity 50 pk
Well-plate Volume 0.5 mL
Quick Connect heat exchanger flow rate mfr 2.5 mL/min
Capillary dimensions mfr 0.12 mm
Preventive maintenance cost reduction mfr 30
Pump seals per PM kit mfr 4
Seal cap assembly sets per PM kit mfr 2
Gold seals for outlet valve per PM kit mfr 2
Seal washes per PM kit mfr 4
Solvent bottles per convenience kit mfr 3 amber
Recommended quantity mfr 2
Cost reduction from PM mfr 30
Finger caps pack size mfr 15 pk
pressure stability mfr 1300 bar
Quick Turn pressure (finger-tight) mfr 600 bar
inline filter pore size (HPLC) mfr 0.5 μm
high-flow heat exchanger volume mfr 3.0 μL
low-dispersion heat exchanger volume mfr 1.1 μL
high flow rate threshold mfr 2.5 mL/min
Interfaces, Connections & Control
Quick Turn Fitting Pressure Limit 800 bar
Solvent bottle thread mfr 45
Fitting diameter mfr 4.7 mm
Adapter thread mfr 45
Materials, Media & Process Compatibility
Adapter material mfr PTFE PTFE

Description

Series positioning and modification scope

Fluidic and pressure behavior

Installation and maintenance architecture

Integration & Operating Notes

Process Limits
Do not exceed 800 bar at Quick Turn fittings

Quick Turn fittings are rated to 800 bar; operating above this limit risks fitting failure and leakage. Verify the system pressure setpoint and pump head rating before installing fittings in high-pressure GPC/SEC methods.

Factory Specification Sheet
Process Limits
Match filter pore size to the mobile-phase particulate load

Solvent filtration uses 47 mm membranes at 0.2 µm, with 2 µm filters also listed; inlet filters are 10 µm. Select the pore size according to the solvent and column protection requirement, since a finer membrane increases backpressure and filtration time.

Factory Specification Sheet
Maintenance
PM kit contains two pump seals and four seal washes

Each preventive maintenance kit includes two pump seals, two seal cap assembly sets, two gold seals for the outlet valve, and four seal washes. Plan seal replacement as a paired service so both pump channels are refreshed together.

Factory Specification Sheet
Maintenance
PM kits are stated to cut maintenance cost by 30%

The supplier states a 30% preventive maintenance cost reduction when using the bundled PM kit rather than individual parts. This figure is a supplier claim and should be validated against local service pricing.

Factory Specification Sheet
Mounting
Solvent bottles use a 45 thread with PTFE adapter

1 L solvent bottles have a 45 thread; PTFE adapters with a 4.7 mm fitting diameter and 45 thread connect the bottle to the solvent inlet line. Confirm thread compatibility before ordering replacement bottles or adapters.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the 1260 Infinity II GPC/SEC configuration instead of the 1220 Infinity II analytical-scale LC or the 1260 purification system?

Choose the GPC/SEC configuration for size-exclusion separations requiring the InfinityLab supply set (0.2 µm filtration, 800 bar fittings, 200 mL/min pump heads). The 1220 analytical-scale system suits compact routine analysis, while the 1260 purification variant adds fraction collection for preparative work.

What pressure rating must adjacent fittings and capillaries meet to integrate with this system's Quick Turn connections?

Quick Turn fittings are rated to 800 bar, and capillaries are 0.17 mm. Adjacent components must be rated at least to the system's maximum operating pressure; the Quick Connect heat exchanger operates at 2.5 mL/min and should be plumbed with matching fittings.

What solvent preparation and filtration supplies are needed before running GPC/SEC methods on this system?

Use 1 L solvent bottles with 45-thread PTFE adapters (4.7 mm fitting), 10 µm inlet filters, and 47 mm filtration membranes at 0.2 µm (2 µm also listed). Filter mobile phase before use to protect columns and reduce baseline noise.

What is included in the preventive maintenance kit and what consumables are not part of base delivery?

The PM kit includes two pump seals, two seal cap assembly sets, two gold seals for the outlet valve, and four seal washes. Solvent bottles, filtration membranes, frits, well plates, and finger caps are separate supply items and are not included with the base instrument.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF