No photo available yet
Agilent Technologies 6.0 CFM
Agilent Technologies 6.0 CFM — Vacuum technologies.
The Agilent IDP 6.0 CFM is a dry scroll pump sized at 6.0 CFM, positioned between the 5.4 CFM and 20.60 CFM siblings in the IDP series. It serves as the backing/roughing stage for high-vacuum systems, with the diffusion-pump pumping speed of 50 L/s listed in the matched performance data. No electrical, ultimate-pressure or interface ratings are verified for this exact model.
Agilent Technologies Idp Pumps Series — Model Comparison & Selection
| Model | Motor power, kW | Ultimate pressure, mbar | Pumping speed, m³/h | Base pressure, mbar | Supply frequency, Hz | Operating temperature, °C |
|---|---|---|---|---|---|---|
| 6.0 CFM Current | — | — | — | — | — | — |
| 20.60 CFM | 0.119 | 3.3 | 3.6 | 3.3 | 50 | — |
| 26.48 CFM | 0.119 | 3.3 | 3.6 | 3.3 | 50 | — |
| IDP-4 | 0.119 | 2.4 | 3.6 | 3.3 | — | 5 |
| Scroll Pumps for Helium Recirculation & Cryogenic Applications | 0.119 | — | 3.6 | 3.3 | — | — |
Full specifications
| Diffusion Pump Pumping Speed | 50 L/s |
| Vacuum gauge measurement range mfr | 6 pressure |
| Dry scroll pump typical size mfr | 3...30 h |
| Turbomolecular pump pumping speed mfr | 70...3 L/s |
| Turbomolecular pump controller protection class mfr | 54 |
Description
Construction and series positioning
- Dry scroll (oil-free) architecture within the Agilent IDP pump family; the model code 6.0 CFM denotes displacement class, not a rating.
- Sits between the 5.4 CFM and 20.60 CFM siblings; the 20.60 CFM and 26.48 CFM siblings carry 0.16 HP motor data, but no motor power is verified for this 6.0 CFM unit.
- The only matched performance figure is a diffusion-pump pumping speed of 50 L/s; treat it as the documented performance entry, not as the pump's own displacement.
Behavior and media
- No digitized curve points, ultimate-pressure value or pumping-speed-vs-inlet-pressure data are available for this model, so load behavior cannot be characterized from the supplied facts.
- The extra factory specs (vacuum gauge range 6, dry scroll typical size 3...30 h, turbomolecular pump 70...3 L/s, controller protection class 54) are series/family context and are not attributable to this model.
Installation and operation
- The attached brochures are application-level e-mobility documents with no model-specific installation, connection or control content; no wiring, flange or controller details can be stated for this unit.
- Certifications and applications lists are empty; no compliance claims are made.
Integration & Operating Notes
Sibling models list 0.16 HP, but no electrical rating is verified for the 6.0 CFM variant; do not size branch protection, cabling or controller output from sibling data. Obtain the model-specific electrical data before integration.
Selection & Integration Q&A
Pick the 6.0 CFM when the required displacement falls between the 5.4 CFM and 20.60 CFM siblings. The 20.60 CFM and 26.48 CFM carry 0.16 HP motor data and 60 L/min / 3.3 mbar figures; no such data is verified for the 6.0 CFM, so confirm its curve before final selection.
The matched data gives only a 50 L/s diffusion-pump pumping speed; no inlet flange, ultimate pressure or electrical rating is verified for this model. Confirm flange size, supply voltage and controller compatibility against the model-specific datasheet before connecting to the high-vacuum stage.
No model-specific mounting, ambient or duty-cycle limits are present in the supplied facts; the attached brochures are application-level e-mobility documents without installation content. Operating position and environment must be taken from the IDP 6.0 CFM instruction manual.
No service interval, consumable list or included-accessory list is verified for this model; the 3...30 h figure in the extra specs is a generic dry-scroll size, not a schedule. Tip-seal kits, cables and controllers must be confirmed as separate items from the IDP manual and price list.