No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Infinity III LC upgrades | Upgrade existing HPLC/UHPLC systems

Agilent Technologies Infinity III LC upgrades | Upgrade existing HPLC/UHPLC systems — Liquid chromatography with Pumping speed 3×10⁻⁵ m³/h.

The Infinity III LC upgrade is a field-installed conversion kit that brings existing HPLC/UHPLC systems to Infinity III functionality, using a 2.1 mm column (part 959758) with 1.8 µm particles and a 10 mm flow cell. It is distinguished within the series from injector-focused upgrade kits by its full flow-path and detection update. It serves laboratories modernizing legacy LC platforms for higher-resolution separations without replacing the entire instrument.

Pumping speed
3×10⁻⁵ m³/h

Agilent Technologies HPLC Uhplc Upgrades Series — Model Comparison & Selection

Model Pumping speed, m³/hColumn particle size, µmDepth, mmFilter membrane pore size, µmFlow cell path length, mmFrequency, Hz
Infinity III LC upgrades | Upgrade existing HPLC/UHPLC systems Current 3×10⁻⁵1.8—0.2210—
Upgrade kits for HPLC injector improve functionality ——795——50

Full specifications

Core Performance & Functional Specifications
Pumping speed 0.5 mL/min
Column Particle Size 1.8 µm
Filter Membrane Pore Size 0.22 µm
Solvent A mfr Water Water
Solvent B mfr ACN ACN
Column dimensions mfr 2.1 mm
Software version mfr 2.8 later
Dimensions, Weight & Mechanical Design
Flow Cell Path Length 10 mm
Standards, Safety & General Data
Column part number mfr 959758

Description

Construction and positioning

Behavior under load and in different media

Installation, connection and control

Integration & Operating Notes

Maintenance
Filter mobile phases through 0.22 µm membranes before use

The specification lists 0.22 µm filter-membrane pore size, indicating that mobile phases must be filtered to this rating to protect the 1.8 µm column and the 10 mm flow cell from particulate contamination. Omitting this step risks column blockage and increased backpressure in the upgraded flow path.

Factory Specification Sheet
Control & I/O
Software version 2.8 is noted as a later requirement

The extra specifications list software version 2.8 with the qualifier 'later', but the attached document digests do not describe the control software, drivers, or firmware for this upgrade. The engineer must confirm the actual required software release and compatibility with the existing data system before installation.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose this Infinity III LC upgrade instead of the injector-focused upgrade kit for HPLC?

Choose this kit when the goal is a full flow-path and detection update around a 2.1 mm, 1.8 µm column and 10 mm flow cell. The sibling injector upgrade kit (3 A motor) addresses injector functionality only; select it when sample introduction is the sole limitation and the existing separation and detection hardware is adequate.

What adjacent system parts and consumables must be in place for this upgrade to work as specified?

The method requires a 2.1 mm column (part 959758) with 1.8 µm particles, a 10 mm path-length flow cell, and 0.22 µm filter membranes for mobile-phase preparation. Water (Solvent A) and acetonitrile (Solvent B) are the specified mobile phase; the pump must deliver 0.5 mL/min. No drive or controller details are given in the verified facts.

What mounting, environment, or duty-cycle limits apply to this upgrade?

The verified facts and attached document digests contain no mounting, environmental, or duty-cycle specifications for this upgrade kit. The digests cover sample ID reading and system brochures, not installation limits. These parameters must be obtained from the full instruction manual before planning the installation.

What maintenance schedule and accessories are required, and what is not included in the base delivery?

The only maintenance-related fact is the 0.22 µm mobile-phase filtration requirement; no service intervals are stated. The 2.1 mm column (part 959758) and filter membranes are consumables that may not be part of the base upgrade delivery. Software version 2.8 is listed as a later requirement, so the required software release must be confirmed separately.

Dimensional Drawings & Technical Documentation

Technical documentation