Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies LDIR Chemical Imaging, IR & Imaging Spectroscopy

Agilent Technologies LDIR Chemical Imaging, IR & Imaging Spectroscopy — Molecular spectroscopy.

The Agilent 8700 LDIR is a quantum-cascade-laser direct-infrared imaging system for automated microplastic and particle analysis. It covers 1800–975 cm⁻¹ with a thermoelectrically cooled MCT detector and acquires a full spectrum in under one second. It is positioned within the Molecular Spectroscopy series for chemical imaging of 20–600 µm particles on aluminum-coated polyester membranes.

Agilent Technologies Molecular Spectroscopy Series — Model Comparison & Selection

Model Wavelength rangeSample volume, milliliterAbsorbance error, %Atr path length, µmAtr surface diameter, mmCertified absorbance value of filter
LDIR Chemical Imaging, IR & Imaging Spectroscopy Current ——————
Fluorescence Spectroscopy Instrumentation, Spectrofluorometers 900—————
FTIR Spectroscopy Equipment 5100...6000.02—2.62.5—
UV-Vis & UV-Vis-NIR Spectroscopy, Cary Instruments ——0.189——0.369

Full specifications

Core Performance & Functional Specifications
Filter Pore Size 0.8 µm
Wavenumber range mfr 1800...975
Infrared source mfr semiconductor-based quantum cascade laser laser
Detector mfr single-point, thermoelectrically cooled mercury
Full spectrum acquisition time mfr less than one second s s
Studied particle size range mfr 20...600 μm
Scanned area, sample 1 (red and white plastic) mfr 3.04
Scanned area, sample 2 (yellow film) mfr 3.76
Substrate mfr 7.5 cm
Instrument mfr 8700 LDIR
Analysis method mfr Particle Analysis Analysis
Spectral library mfr inbuilt microplastics spectral library library
Filter type mfr aluminum-coated polyester membrane membrane
Sample preparation mfr imal imal
Quality control mfr procedural blanks recommended recommended
Particles detected mfr 660
Particles with HQI > 0.85 mfr 50
Most prevalent polymers mfr PVC and PET PET

Description

Construction and positioning

Behavior and analysis mode

Operation and control

Integration & Operating Notes

Maintenance
Run procedural blanks with every sample batch

Procedural blanks are recommended as quality control to distinguish sample-derived particles from background contamination; without them, particle counts and polymer assignments cannot be confidently attributed to the sample.

Application Note, Microplastics in Environmental Samples
Control & I/O
Clarity software drives acquisition and library matching

The application notes describe operation with Agilent Clarity software for spectral acquisition and comparison against the inbuilt microplastics spectral library; the software environment is therefore part of the analysis chain and must be planned for in the laboratory IT setup.

Application Note, Spice Adulteration

Selection & Integration Q&A

When should I choose the 8700 LDIR instead of the FTIR or Raman siblings in this series?

Choose the 8700 LDIR for automated imaging and identification of 20–600 µm particles on membrane filters, using the 1800–975 cm⁻¹ QCL range and inbuilt microplastics library. The FTIR sibling covers 5100–600 cm⁻¹ for broader bulk spectra, and the Raman sibling uses spatially offset Raman; select those when their spectral range or technique is required rather than particle imaging.

What sample presentation and consumables are needed before the instrument can analyze a filter?

Samples are collected on 0.8 µm aluminum-coated polyester membranes, which serve as the reflective substrate for the laser measurement. Procedural blanks should be prepared alongside samples for quality control. The supplied facts do not list membranes, blanks, or other consumables as part of base delivery, so they must be sourced separately.

What quality-control and software provisions should be planned for routine operation?

Plan for procedural blanks with each batch to control contamination, and for Agilent Clarity software for acquisition and library matching. The application notes report 660 particles detected with 50 above HQI 0.85 in a beach-sample run, so HQI thresholds should be set as part of the analysis method. No service intervals or accessory lists are given in the supplied documents.