Agilent Technologies Fluorescence Spectroscopy Instrumentation, Spectrofluorometers
Agilent Technologies Fluorescence Spectroscopy Instrumentation, Spectrofluorometers — Molecular spectroscopy.
The Cary Eclipse is a benchtop fluorescence spectrophotometer using a xenon flash lamp and a red-sensitive photomultiplier extended to 900 nm. It supports fluorescence, phosphorescence, chemiluminescence and bioluminescence modes, with kinetics data collection at 80 points/s and scan speeds to 24000 nm/min. It is positioned for life-science and analytical labs needing sensitive, fast spectral acquisition.
Agilent Technologies Molecular Spectroscopy Series — Model Comparison & Selection
| Model | Wavelength range | Sample volume, milliliter | Absorbance error, % | Atr path length, µm | Atr surface diameter, mm | Certified absorbance value of filter |
|---|---|---|---|---|---|---|
| Fluorescence Spectroscopy Instrumentation, Spectrofluorometers Current | 900 | — | — | — | — | — |
| FTIR Spectroscopy Equipment | 5100...600 | 0.02 | — | 2.6 | 2.5 | — |
| LDIR Chemical Imaging, IR & Imaging Spectroscopy | — | — | — | — | — | — |
| UV-Vis & UV-Vis-NIR Spectroscopy, Cary Instruments | — | — | 0.189 | — | — | 0.369 |
Full specifications
| Wavelength range | 900 nm |
| Cuvette Volume | 5 µL |
| Kinetics Data Collection Rate | 80 points/s |
| Minimum Reduced-volume Cuvette Volume | 5 µL |
| Red-sensitive Photomultiplier Sensitivity Extension | 900 nm |
| Scan speed | 24000 nm/min |
| Typical Lamp Life | 10 years |
| Wavelength range scan time mfr | 3 s |
| Xenon flash lamp lifetime mfr | 3 flashes |
| Wavelength scan time (full range) mfr | 3 s |
| Lamp type mfr | xenon flash lamp lamp |
| Lamp lifetime mfr | 3 flashes |
| Detection sensitivity mfr | picoMolar amounts of fluorescein fluorescein |
| microplate reader conversion time mfr | 30 seconds |
| 96-well measurement time mfr | 50 seconds |
| 384-well measurement time mfr | 90 seconds |
| image spot size mfr | 2 mm |
| polarizer excitation limit mfr | 275 nm |
| Bench footprint mfr | 600 mm |
| Bench space (footprint) mfr | 600 mm |
| bench footprint mfr | 600 mm |
Description
Construction and positioning
- Benchtop fluorescence spectrophotometer with a 600 mm bench footprint, using a xenon flash lamp rather than a continuous-wave source.
- Within the Molecular Spectroscopy series, this is the fluorescence/phosphorescence/chemiluminescence/bioluminescence member; FTIR, LDIR imaging, Raman and UV-Vis/UV-Vis-NIR are separate sibling instrument families, not configurations of this model.
- A red-sensitive photomultiplier extends detection to 900 nm, distinguishing it from standard UV-Vis fluorescence setups.
Behavior and modes
- Four acquisition modes are supported: fluorescence, phosphorescence, chemiluminescence and bioluminescence.
- Kinetics data collection runs at 80 points/s; scan speed reaches 24000 nm/min, with a 3 s wavelength-range scan time.
- Minimum reduced-volume cuvette volume is 5 µL, enabling small-sample work.
Installation and operation
- The brochure digest provides no ordering codes, electrical ratings, interface details or maintenance schedules; these must be obtained from the full instruction manual before integration.
- Lamp lifetime is stated as 10 years typical and 3 flashes in the extra specs; these two figures are inconsistent and neither should be used for service planning without confirmation.
Integration & Operating Notes
The 5 µL figure applies to the minimum reduced-volume cuvette; standard cuvettes and larger volumes require separate verification. Below the stated minimum, path length and signal-to-noise degrade, so assay volumes must be validated against the actual cell used.
The specification lists a typical lamp life of 10 years and, separately, a xenon flash lamp lifetime of 3 flashes. These cannot both describe the same lamp. Obtain the correct replacement interval and part number from Agilent service documentation before setting a preventive-maintenance schedule.
At 80 points/s, the shortest resolvable interval between kinetics data points is 12.5 ms. Reactions faster than this cannot be resolved without changing acquisition settings, so assay design must match the chemistry to this sampling limit.
Selection & Integration Q&A
Choose this model for fluorescence, phosphorescence, chemiluminescence or bioluminescence work needing 900 nm red-sensitive detection and 80 points/s kinetics. FTIR, Raman and UV-Vis/UV-Vis-NIR are separate instrument families for absorption, vibrational or imaging measurements, not interchangeable configurations.
The available brochure digest lists no electrical ratings, interface protocols or controller requirements. Confirm power, data interface and control software from the full instruction manual before specifying a PC, autosampler or LIMS connection; do not assume standard ports.
The supplied documents contain no operating temperature, humidity or duty-cycle data. The xenon flash lamp is pulsed rather than continuous, but flash rate and thermal limits are not stated. Obtain environmental specifications from Agilent before placing the unit in a non-climate-controlled lab.
Lamp replacement interval is unresolved: the sheet states both 10 years typical and 3 flashes. Cuvettes, reduced-volume cells and any control computer are not described as included. Confirm lamp part number, cuvette options and software licensing with Agilent before purchase.