No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1,2, or 3 Laser Benchtop Flow Cytometer, NovoCyte Advanteon 

Agilent Technologies 1,2, or 3 Laser Benchtop Flow Cytometer, NovoCyte Advanteon  — Research flow cytometry.

The NovoCyte Advanteon is a benchtop flow cytometer configured with one to three solid-state lasers, each with onboard thermal-electric cooling, and a fixed 170 µm flow cell. It acquires up to 100,000 events/s at sample flow rates of 5–120 µL/min, with volumetric absolute counting at 5% precision. It serves as the entry-to-mid configuration of the NovoCyte series for routine immunophenotyping and volumetric cell analysis.

Agilent Technologies Flow Cytometer Systems Series — Model Comparison & Selection

Model Pumping speed, m³/hSample flow rate, µL/minSheath flow rate, mL/minVolumetric absolute count precision, %Laser power, WPrint technology
1,2, or 3 Laser Benchtop Flow Cytometer, NovoCyte Advanteon  Current —5...1206.550.405Solid state laser with o
1-3 laser benchtop flow cytometer, NovoCyte 3×10⁻⁶5...1206.55——
4 Laser Flow Cytometer, NovoCyte Quanteon —5...1206.550.405Solid state laser with o
5 Laser Flow Cytometer, NovoCyte Penteon —5...1206.550.405Solid state laser with o

Full specifications

Core Performance & Functional Specifications
Laser power 405 mW
Print technology Solid state laser with onboard thermal-electric cooling
Sample Flow Rate 5...120 μL/min
Sheath Flow Rate 6.5 mL/min
Ssc Sensitivity 0.1 μm
Volumetric Absolute Count Precision 5 %
Laser beam profile mfr 10 μm
Fluorescence detection mfr Silicon photomultiplier with individual photodet
FSC sensitivity mfr 0.4 μm
Fluorescence threshold sensitivity mfr 40 MESF
Fluorescence resolution mfr 3 % CV
Flow cell mfr 170 μm
Sample acquisition rate mfr 100000 events/second
Sample acquisition volume mfr 5 mL
Manual sample format mfr 12 tube

Description

Construction and series positioning

The Advanteon is the 1–3 laser member of the NovoCyte family; the Quanteon carries 4 lasers and the Penteon 5. Fluorescence is detected by silicon photomultipliers with an individual photodetector per channel, and the optical bench uses solid-state lasers with onboard thermal-electric cooling. The 170 µm flow cell and 10 µm laser beam profile define the core optical geometry. Choose the Advanteon when the panel fits within three laser lines; step to the Quanteon or Penteon only when additional excitation lines are required.

Analytical behavior

Sensitivity is specified at 0.4 µm for FSC and 0.1 µm for SSC, with a fluorescence threshold of 45 MESF and fluorescence resolution of 3% CV. Sample acquisition rate reaches 100,000 events/s, while the sample flow rate is adjustable from 5 to 120 µL/min and the sheath flow rate is 6.5 mL/min. Volumetric absolute counting is performed directly with 5% precision, so no reference beads are needed for concentration readout. The 5 mL sample acquisition volume and 12-tube manual format set the per-run workload.

Installation and operation

The datasheet digest covers the NovoCyte Penteon, Quanteon and Advanteon together and provides no installation, connection or control details specific to this model; those must be taken from the instrument user manual. No certificates or application notes were supplied with the verified facts.

Integration & Operating Notes

Process Limits
Keep acquisition rate within the 100,000 events/s ceiling

Samples concentrated enough to exceed 100,000 events/s will be acquired at the instrument ceiling, and any coincident-event rejection at that point biases the population statistics. Dilute high-concentration samples or reduce the sample flow rate before acquisition so the event rate stays below the stated maximum.

Factory Specification Sheet, Sample acquisition rate
Process Limits
Match sample flow rate to the 5–120 µL/min range

The sample flow rate is adjustable from 5 to 120 µL/min against a fixed sheath flow rate of 6.5 mL/min. Volumetric absolute counts are derived from the sample flow setting, so the chosen rate must remain stable throughout the acquisition for the 5% volumetric precision to hold.

Factory Specification Sheet, Sample flow rate and sheath flow rate
Maintenance
Plan fluidics and optical service per the user manual

The supplied datasheet digest contains no maintenance intervals, error codes or service procedures for the Advanteon. The fluidic system, flow cell and thermal-electric laser cooling require scheduled service defined in the instrument user manual; obtain that manual before commissioning.

Datasheet digest, scope and variants
Electrical
Electrical ratings are not covered by the supplied facts

No supply voltage, current or power figures for the Advanteon were included in the verified specifications. Site power planning must rely on the instrument user manual or nameplate rather than on this card.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the Advanteon rather than the Quanteon or Penteon?

Pick the Advanteon when the panel needs one to three laser lines; it is the 1–3 laser configuration of the NovoCyte series. Move to the Quanteon (4 lasers) or Penteon (5 lasers) only when additional excitation lines are required for the panel.

What sample format and volume does the Advanteon accept, and what does that mean for upstream sample prep?

The manual sample format is 12 tubes with a 5 mL sample acquisition volume. Upstream preparation must deliver single-cell suspensions in that tube format; the datasheet digest gives no plate-handler or automation interface details for this model.

What duty-cycle and environmental limits apply to the Advanteon?

The verified facts contain no duty-cycle, ambient temperature or humidity limits for this model. The datasheet digest covers Penteon, Quanteon and Advanteon jointly without environment data, so these limits must be read from the instrument user manual before siting.

What maintenance and consumables are required, and what is not included in base delivery?

No maintenance schedule, sheath fluid, cleaning reagents, QC beads or cables are listed in the verified facts. Service intervals and consumable part numbers are defined in the user manual, which was not supplied; confirm them with the vendor before commissioning.

Dimensional Drawings & Technical Documentation

Technical documentation