Agilent Technologies Protein Capillary Electrophoresis Instrument
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Protein Capillary Electrophoresis Instrument

Agilent Technologies Protein Capillary Electrophoresis Instrument — Automated electrophoresis.

The Agilent ProteoAnalyzer is an automated capillary electrophoresis instrument for protein sizing and quantification, using the Protein Broad Range P240 kit. It analyzes 12 samples simultaneously per run in about 30 minutes, covering 10–240 kDa and 2–2,000 ng/µL. It is distinguished within the Proteoanalyzer series by its dedicated protein chemistry and broad-range kit compatibility.

Agilent Technologies Proteoanalyzer Systems Series — Model Comparison & Selection

Model SensitivityRun time, minSoftwareAnalysis time for 12 samples, minutesDetector typeLower marker size, kDa
Protein Capillary Electrophoresis Instrument Current 130———6
CE-SDS Protein Analysis Capillary Array, ProteoAnalyzer —30Agilent ProSize data ana30charge-coupled device —

Full specifications

Core Performance & Functional Specifications
Sensitivity 1 PBS
Lower Marker Size 6 kDa
Overall Average Size (bsa) 69.2 kDa
Overall Average Size (caii) 28.0 kDa
Resolution 1 milligram
Run Time 30 min
Typical Sizing Accuracy (lm And Um) 10 %
Typical Sizing Accuracy (lm Only) 15 %
Typical Sizing Accuracy (% Sizing Error) 15 %
Samples analyzed simultaneously per run mfr 12 samples
Detection concentration range mfr 2...2,000 ng/μL
Upper marker precision benefit mfr 200 kDa
Sample buffer mfr 1 PBS
CAII extinction coefficient mfr 0.575
Sizing precision mfr 8 % CV
Sample input concentration range mfr 2...2,000 ng/μL
Overall accuracy (BSA) mfr -10.25 % error
Overall precision (BSA) mfr 1.53 % CV
Overall accuracy (CAII) mfr -19.43 % error
Overall precision (CAII) mfr 1.43 % CV
Linearity R2 (CAII) mfr 0.9998
Sizing range (LM only) mfr 10...240 kDa
Resolution (NIST mAb NGHC/HC) mfr 1
Sizing precision (LM only) mfr 8 mAb
Sizing precision (LM only, intact NIST mAb) mfr 10 %CV
Sizing precision (LM and UM) mfr 5 mAb
Overall accuracy BSA mfr -19.43 % error
Overall accuracy CAII mfr -3.55 % error
Overall precision BSA mfr 13.71 %CV
Overall precision CAII mfr 2.10 %CV
Linearity R2 CAII mfr 0.9998
Linearity R2 mfr 0.9381
Quantitative Range mfr 2 PBS
Quantification Reproducibility mfr 20...2,000 BSA
Quantification reproducibility (low range) mfr 2...20 BSA
Sample volume required mfr 1 μL
Capillary array channels mfr 12 channel
SDS-PAGE separation time mfr 40 minutes
Heat denaturation time mfr 5 minutes
DTT final concentration mfr 50 mM
SDS-PAGE loading volume mfr 10 μL
Electrical, Power & Drive Specifications
SDS-PAGE separation voltage mfr 200 V
Operating Conditions, Environment & Protection
Sensitivity (Signal/Noise > 3) mfr 1 PBS

Description

Construction and positioning

Performance behavior

Installation, control and operation

Integration & Operating Notes

Process Limits
Sizing valid only within 10–240 kDa with the P240 kit

Samples outside the 10–240 kDa sizing range or outside 2–2,000 ng/µL input concentration fall outside the stated kit performance; accuracy and precision figures apply only within these ranges and with the specified marker mode.

Technical Overview 5994-6718EN; Technical Overview 5994-6934EN
Process Limits
Marker mode determines sizing accuracy tier

Using both lower and upper markers yields typical sizing accuracy of 10%, while lower-marker-only operation is stated at 15%; the upper marker (200 kDa) provides the stated precision benefit, so method design must select the marker mode deliberately.

Technical Overview 5994-6934EN
Maintenance
Kit and capillary array are separate consumables

The Protein Broad Range P240 kit (5191-6640) and the CE-SDS Protein Analysis Capillary Array are distinct items from the instrument; the available digests do not specify replacement intervals or base-delivery contents.

Technical Overview 5994-6934EN

Selection & Integration Q&A

When should I choose the ProteoAnalyzer rather than the CE-SDS Protein Analysis Capillary Array sibling?

The ProteoAnalyzer is the instrument; the CE-SDS Protein Analysis Capillary Array is a consumable used with it. Choose the instrument for automated protein sizing/quantification; the array is a replacement/consumable item, not an alternative system.

What kit and marker configuration must be used with this instrument for protein sizing?

Use the Protein Broad Range P240 kit (5191-6640). Sizing accuracy is 10% with lower and upper markers versus 15% with lower marker only; the upper marker is 200 kDa and the lower marker 6 kDa.

What sample concentration and size limits apply before loading?

Input concentration must be 2–2,000 ng/µL and protein size within 10–240 kDa for the stated performance; outside these ranges the accuracy and precision figures do not apply.

What maintenance or accessory information is available for this model?

The available document digests contain no maintenance schedule, service intervals, or accessory/cable list; only the P240 kit and capillary array are identified as separate consumables. Consult the instrument manual for service details.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve performance curve performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
Quality Analysis Using the ProteoAnalyzer System
Datasheet ·1,1 МБ ·10 pp.
View PDF