No photo available yet
Agilent Technologies High Speed Rotary Pumping Station 4000 m3/h; RPS-4001/631
Agilent Technologies High Speed Rotary Pumping Station 4000 m3/h; RPS-4001/631 — Vacuum technologies.
The RPS-4001/631 is a high-speed Roots pumping station rated at 4000 m³/h, positioned at the top of the RPS series above the 1000, 1400, 2000 and 500 m³/h siblings. It is built for high-throughput roughing and backing duty in large vacuum systems, where the 4000 m³/h stage handles the bulk gas load.
Agilent Technologies Roots Pumping Systems Rps Series — Model Comparison & Selection
| Model | Diffusion pump pumping speed, L/s |
|---|---|
| High Speed Rotary Pumping Station 4000 m3/h; RPS-4001/631 Current | 50 |
| Fast Roughing Roots Pumping Station 1400 m3/h; RPS-1401/301 | 50 |
Full specifications
| Diffusion Pump Pumping Speed | 50 L/s |
| Vacuum gauge measurement range mfr | 6 pressure |
| Dry scroll pump typical size mfr | 3...30 h |
| Turbomolecular pump pumping speed mfr | 70...3 L/s |
| Turbomolecular pump controller protection class mfr | 54 |
Description
Construction and series positioning
- The RPS-4001/631 is the largest high-speed Roots station in the RPS family; siblings include the RPS-1001/301 (1000 m³/h), RPS-1401/301 (1400 m³/h), RPS-2001/631 (2000 m³/h) and RPS-501/301 (500 m³/h).
- The model code denotes a 4000 m³/h Roots stage; the /631 suffix identifies the backing-pump configuration within the series.
- No construction drawings, materials or dimensional data are provided in the verified facts; the card therefore does not assert chamber geometry, flange sizes or weight.
Performance behavior
- The only matched performance spec is a diffusion-pump pumping speed of 50 L/s, which describes an adjacent high-vacuum stage rather than the Roots station itself.
- No curve points were supplied, so no pressure-dependent throughput or ultimate-pressure behavior can be stated for this model.
- Extra factory specs list a vacuum gauge measurement range of 6 (unit given as pressure), a dry scroll pump typical size of 3...30 h, and a turbomolecular pump pumping speed of 70...3 L/s; these values are internally inconsistent or unit-ambiguous and are not used as RPS-4001/631 ratings.
Controls and operation
- The attached brochures are application-level e-mobility documents and contain no model-specific installation, control or connection facts for the RPS-4001/631.
- Turbomolecular pump controller protection class IP54 is noted in the extra specs but belongs to a turbomolecular controller, not to the Roots station.
- No certificates or applications are listed for this model.
Selection & Integration Q&A
Pick the RPS-4001/631 when the roughing load requires a 4000 m³/h Roots stage, the largest in the series. The RPS-2001/631 shares the /631 backing configuration but delivers 2000 m³/h; the RPS-1001/301 is a 1000 m³/h unit with a different backing suffix. Choose a smaller sibling when 4000 m³/h exceeds the process gas load.
The verified facts do not specify the required backing-pump size or foreline flange for the RPS-4001/631. Because the /631 suffix is shared with the 2000 m³/h model, the backing stage cannot be inferred from the model code; obtain the Agilent datasheet to confirm backing capacity and flange dimensions before ordering mating fittings.
No mounting orientation, ambient temperature, vibration or duty-cycle data is present in the verified facts or the attached e-mobility brochures. These limits must be taken from the model-specific instruction manual; the IP54 figure in the extra specs belongs to a turbomolecular pump controller and does not describe this Roots station.
The verified facts list no maintenance intervals, spare parts or included accessories for this model, and the brochures are application-level only. Cables, controllers and consumables should be treated as not included until the RPS-4001/631 manual and ordering code list are obtained from Agilent.