No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 4300 Handheld FTIR

Agilent Technologies 4300 Handheld FTIR — Molecular spectroscopy.

The Agilent 4300 Handheld FTIR is a portable, weather-resistant spectrometer with a DTGS detector covering 4500–650 cm⁻¹, designed for field analysis. It weighs 2 kg and operates on battery for up to 4 hours or via a 15 V DC external supply. Interchangeable sampling interfaces—45° and grazing-angle reflectance, diffuse reflectance, diamond ATR, and germanium ATR—enable solids, liquids, and surface films to be measured outside the laboratory.

Full specifications

Core Performance & Functional Specifications
Wavelength range 4500...650
Laser Low-powered solid state
Spectral resolution 4 dimensionless
External reflectance angle of incidence mfr 45 degrees
Grazing angle of incidence mfr 82 degrees
Energy (centerburst) — Optimal mfr 29000
Energy (centerburst) — Marginal mfr 29000
Energy (centerburst) — Critical mfr 31000
Laser signal — Optimal mfr 15000
Laser signal — Marginal mfr 15000
Laser signal — Critical mfr 17000
Performance test resolution mfr 4
Performance test collection time mfr one-minute minute
Performance test duration mfr 2 test
Recommended reflectance absorbance range mfr 0.1 AU
Energy (centerburst) diagnostic — Optimal mfr 29000
Energy (centerburst) diagnostic — Marginal mfr 29000
Energy (centerburst) diagnostic — Critical mfr 31000
Laser signal diagnostic — Optimal mfr 15000
Laser signal diagnostic — Marginal mfr 15000
Laser signal diagnostic — Critical mfr 17000
Warm-up time before performance validation mfr 30 minutes
External reflectance absorbance range mfr 0.1 AU
Grazing angle of incidence mfr 82 degrees
Interferometer geometry mfr High-throughput Michelson interferometer with fi
Source mfr Wire-wound element element
DTGS Spectral range mfr 4500...650
MCT Spectral range mfr 5000...1100
Detector mfr 1.3 MCT
Unpacking mfr 9
Components mfr 11
Connecting power mfr 12
Changing the desiccant mfr 16
Turning on the instrument mfr 17
Starting the software mfr 18
Communication to external PC mfr 19
Performance verification mfr 19
G8180-67560 mfr Coarse Gold Reference Cap Cap
G8180-67562 mfr SS Mirror Reference Cap Cap
G8180-67563 mfr Coarse Silver Diff Reference Cap Cap
G8180-67564 mfr Gold Mirror Reference Cap Cap
G8180-67300 mfr 4300 Sample
G8180-67147 mfr 4300 Battery
G8180-67000 mfr 4300 Charger
G8180-67135 mfr 4300 Supply
G8180-67610 mfr 4300 Reflector
G8181-67611 mfr 4300 Reflector
X3202-60106 mfr O-Ring Removal Tool Tool
G8184-67000 mfr 4300 Kit
G8184-67001 mfr O-Ring Replacement Kit Kit
G8184-67002 mfr O-Ring Replacement Kit Kit
G8180-67514 mfr 4300 Cartridge
G8180-68001 mfr 4300 ATR
G8180-68002 mfr 4300 ATR
G8180-68003 mfr 4300 Ref
G8180-68004 mfr 4300 Ref
G8180-68005 mfr 4300 Ref
G8180-20029 mfr 4300 strap
Diffuse reflectance mfr • Suitable for analysis of samples that reflect
Ingress protection mfr 54
Dimensions, Weight & Mechanical Design
Depth 19.05 cm
Diamond Atr Depth Of Penetration 2 micron
Height 34.5 cm
Weight 2 kg
Width 10.16 cm
Ge ATR analysis depth mfr 0.5...2 micrometers
Germanium ATR analysis depth mfr 0.5...2 micrometers
Weight without batteries mfr 1.88 kg
Weight with batteries mfr 2.22 kg
Electrical, Power & Drive Specifications
Battery Life Under Continuous Use 4 hours
Battery Operating Time 4 hours
Power supply 100...240 Hz
External power supply output mfr 15 DC
Battery life — Optimal mfr 30 min
Battery life — Marginal mfr 5 min
Battery life — Critical mfr 5 min
Source current — Optimal mfr 1.9 A
Source current — Marginal mfr 2.2 A
Source current — Critical mfr 2.5 A
AC power input mfr 110 AC
Battery life diagnostic — Optimal mfr 30 min
Battery life diagnostic — Marginal mfr 5 min
Battery life diagnostic — Critical mfr 5 min
Source diagnostic — Optimal mfr 1.9 A
Source diagnostic — Marginal mfr 2.2 A
Source diagnostic — Critical mfr 2.5 A
Battery voltage mfr 10.8 volt
Power supply output mfr 15 DC
Interfaces, Connections & Control
Sample interface mfr 45 Reflectance
Materials, Media & Process Compatibility
Diamond ATR sample pH range mfr 1...14 pH
Diamond ATR pH range mfr 1...14
Operating Conditions, Environment & Protection
Operating temperature 32...122 °F
Operating humidity mfr 95
Standards, Safety & General Data
Standard beamsplitter mfr Zinc selenide selenide
IEC/EN 60529 mfr 54

Description

Construction and positioning

Behavior under load and in different media

Installation, control, and operation

Integration & Operating Notes

Electrical
Use only the specified 15 V DC power supply and a surge protector

The 4300 requires the included 15 V DC external power supply (part G8180-67135). Substituting another supply may damage the instrument. Always connect through a UL-approved surge protection strip to guard against power surges or faulty outlets, especially in field locations.

Operation Manual, AC power / p.14-15
Process Limits
Keep external reflectance absorbance between 0.1 and 2 AU

For valid spectra with external reflectance interfaces, the absorbance must fall within 0.1–2 AU. Use the real-time data viewer to adjust sample contact or reference cap selection. Values outside this range indicate poor sample contact or inappropriate reference reflectivity.

Operation Manual, Collecting a sample spectrum / p.27
Maintenance
Replace or recharge desiccant regularly to protect optics

The removable desiccant cartridge is located behind the back access panel. Replace with new or recharged desiccant as needed to prevent moisture condensation inside the optical housing, which can degrade spectral performance. The manual does not specify a fixed interval; monitor diagnostic values for signs of moisture.

Operation Manual, Changing the Desiccant / p.17

Selection & Integration Q&A

When should I choose the 4300 Handheld FTIR with DTGS detector instead of a laboratory FTIR or the discontinued MCT variant?

Choose the DTGS 4300 for portable field use where 4500–650 cm⁻¹ coverage and ambient-temperature operation (0–50 °C) are sufficient. The MCT variant (5000–1050 cm⁻¹) is no longer available. A lab FTIR offers higher stability but lacks the 2 kg handheld form factor and battery operation.

What are the power and communication requirements when integrating the 4300 with an external PC for method development?

Use the included 15 V DC power supply (G8180-67135) with a UL-approved surge protector. Connect to the PC via the separate USB port. The instrument can also run standalone on its integrated CPU; external PC connection is for method development and detailed spectral viewing.

What environmental and duty-cycle limits apply when using the 4300 in the field?

Operate within 0–50 °C and up to 95% humidity. Battery provides up to 4 hours; carry spare charged batteries for extended sessions. Do not immerse in water; clean with a damp cloth only. The instrument is not intrinsically safe—avoid flammable atmospheres.

What maintenance items and accessories are not included in the base delivery but are needed for routine operation?

The base delivery includes four Li-ion batteries, battery charger, power supply, USB cable, Retro-Reflector Reference Interface, polystyrene reference sample, and MicroLab Software UFD. Spare desiccant cartridges, replacement O-rings, additional sampling interfaces (diamond ATR, Ge ATR, grazing-angle, diffuse reflectance), and reference caps are available as spare parts and must be ordered separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operation Manual
Manual ·54 pp.
View PDF