Agilent Technologies Large Dry Scroll Pumps, TriScroll Vacuum Pumps
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Large Dry Scroll Pumps, TriScroll Vacuum Pumps

Agilent Technologies Large Dry Scroll Pumps, TriScroll Vacuum Pumps — Vacuum technologies with Motor power 0.119 kW, Pumping speed 3.6 m³/h.

The Agilent TriScroll is a large dry scroll vacuum pump with a 60 L/min pumping speed and 0.16 HP motor, operating on 100 VAC to reach a base pressure of 3.3 mbar. It is positioned within the Dry Scroll Pumps series as the larger-capacity modification relative to the small IDP series, intended for oil-free roughing and backing duties in analytical and laboratory vacuum systems.

Motor power
0.119 kW
Pumping speed
3.6 m³/h

Agilent Technologies Dry Scroll Pumps Series — Model Comparison & Selection

Model Motor power, kWPumping speed, m³/hBase pressure, mbar
Large Dry Scroll Pumps, TriScroll Vacuum Pumps Current 0.1193.63.3
Scroll Pumps IDP Series, Small, Dry & Hermetic Vacuum 0.1193.63.3

Full specifications

Core Performance & Functional Specifications
Motor power 0.16 HP
Pumping speed 60 L/min
Base Pressure 3.3 mbar
IDP-10 mfr 3810
IDP-10 with inlet isolation valve mfr 3810
IDP-7/10 tip seal replacement kit mfr 3807
Exhaust silencer kit mfr 110
Purge kit mfr 3807
Gas ballast kit mfr 3807
Inlet trap mfr 25
Vibration isolation kit mfr 110 VIBISOKIT
IDP-35 mfr 3835
IDP-35 with Gauge mfr 3835
IDP-35 with Inlet Valve mfr 3835
IDP-35 with Inlet Valve and Gauge mfr 3835
Inlet HEPA filter, NW40 mfr 40
HEPA filter, NW25 mfr 25
IDP-45 mfr 3845
IDP-45 with Gauge mfr 3845
IDP-45 with Inlet Valve mfr 3845
IDP-45 with Inlet Valve and Gauge mfr 3845
IDP-15 mfr 3815
IDP-15 with inlet isolation valve mfr 3815
IDP-15 tip seal replacement kit mfr 3815
IDP-3 mfr Vibration isolation kit kit
IDP-4 mfr Replacement filter element element
IDP-7 mfr Vibration isolation kit kit
inlet valve closing time mfr 20 milliseconds
inlet valve opening time after power restore mfr 10 seconds
tip seal replacement duration mfr half an hour hour
IDP-4 maintenance duration mfr 15...30 minutes
integrated Pirani gauge pressure range mfr -4...1000 mbar
VPI valve isolation time mfr 20 ms
green energy consumption mfr 4 GWh
CO2 avoided mfr 1350 Tons
solar energy generation mfr 634 MWh
CO2 saved mfr 214 tons
airfreight CO2 emission mfr 600 kilometer
water saving mfr 250 year
wastewater reduction mfr 41
energy reduction mfr 35 MWh
CO2 emission reduction mfr 12 ton
Electrical, Power & Drive Specifications
Operating voltage mfr 100 VAC
IDP-35/IDP-45 supply frequency mfr 50 Hz
startup current mfr 10 A
Operating Conditions, Environment & Protection
cooling liquid reduction mfr 20...40 percent

Description

Construction and series positioning

Operating envelope

Installation and control

Integration & Operating Notes

Electrical
Confirm 100 VAC supply compatibility before connection

The only stated operating voltage for this model is 100 VAC. The IDP family digest mentions 100–120/200–240 VAC motor variants across that family, but no variant table exists for this TriScroll unit, so the supply must be verified against the nameplate rather than assumed to accept 200–240 VAC.

Factory Specification Sheet; IDP Dry Scroll Pump Family Brochure 5991-7583EN

Selection & Integration Q&A

When should I choose this TriScroll large dry scroll pump instead of a small IDP series pump?

Choose the TriScroll when the duty calls for a large dry scroll pump in the Dry Scroll Pumps series; the sibling IDP series is described as small, dry and hermetic. Both share 60 L/min and 0.16 HP in the supplied data, so the deciding factor is the large-versus-small series positioning, not the listed performance figures.

What supply and adjacent-component requirements must be met before integrating this pump?

The stated operating voltage is 100 VAC, so the supply must match the nameplate; do not assume 200–240 VAC compatibility even though the IDP family digest lists such variants for that family. No controller, cable or mating-flange data was supplied, so those interfaces must be confirmed from the model-specific manual.

What mounting and duty-cycle limits apply to this model?

The verified facts contain no mounting orientation, ambient temperature or duty-cycle limits, and the attached document digests yielded no actionable engineering facts. These limits must be taken from the model-specific instruction manual before installation; they cannot be inferred from the 3.3 mbar base pressure or 60 L/min speed.

What maintenance schedule and accessories are included with the base delivery?

No maintenance intervals, error codes, cables, consumables or accessory part numbers are documented in the supplied facts or document digests. The base delivery content and service schedule must be confirmed against the model-specific manual and ordering information, which were not part of the verified material.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent IDP-4 Dry Scroll Vacuum Pump
Brochure ·10,7 МБ ·11 pp.
View PDF
PDF
Sustainability in the Vacuum Industry
Brochure ·19,1 МБ ·16 pp.
View PDF