Elmo Rietschle 2BV7061
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BV7061

Elmo Rietschle 2BV7061 — Liquid Ring Vacuum Pumps with Motor power 2.5 kW.

The 2BV7061 is a liquid-ring vacuum pump/compressor from the L-BV7N series, built as a close-coupled pump-motor unit with a 2.5 kW IE3 motor and IP55 protection. It is the -1 variant of the 2BV7061, distinguishing it from the -2 and -3 variants of the larger 2BV7060, 2BV7070 and 2BV7071 models. It is intended for vacuum generation or low-pressure compression where a nominal operating-liquid flow of 0.23 m³/h and a priming fill of 0.55 l are required.

Motor power
2.5 kW

Elmo Rietschle L-BV7 Series — Model Comparison & Selection

Model Max inlet pressure, kPaMotor power, kWNoise level, dBPower supplyWeight, kgOperating principle
2BV7061 Current 1.92.570AC30—
2BV7060 2001.670AC20Liquid ring
2BV7070 8—72200 VΔ39Liquid ring
2BV7071 86.376AC68Liquid ring

Full specifications

Core Performance & Functional Specifications
Max inlet pressure 1.9 bar abs. (50 Hz)
60 Hz: 1.9 bar abs.
Motor power 2.5 kW (50 Hz)
Dimensions, Weight & Mechanical Design
Weight 30 kg
Weight approx. (alt var) mfr 66 lb
Electrical, Power & Drive Specifications
Power supply AC (3~ 50/60 Hz)
Operating Conditions, Environment & Protection
Noise level 70 dB(A) (50 Hz)
60 Hz: 70 dB(A)
Operating temperature 80 °C
Protection rating IP55
Ambient temperature limit 40 °C

Description

Construction and series positioning

Behavior under load and in different modes

Installation, connection and operation

Integration & Operating Notes

Process Limits
Pumped gas temperature must stay at or below 80 °C

The maximum temperature of pumped gases/vapors is +80 °C. Higher temperatures require system measures to prevent burns, such as a separating safety device (cover). Also ensure the operating-liquid temperature remains between +5 °C and +80 °C, as the minimum inlet pressure depends on it.

Operating Instructions, Chapter 4.3, p. 10-11
Mounting
Foundation must limit vibration velocity to 4.5 mm/s

The installation surface and foundation must ensure that the total vibration velocity does not exceed 4.5 mm/s. Higher vibration shortens service life and can cause mechanical damage. Use the specified 4 x M8-6.8 bolts for the 2BV706 frame size and verify vibration after installation.

Operating Instructions, Chapter 7.1, p. 16-17
Mounting
Maintain 34 mm clearance from fan guard for cooling

A minimum distance of 34 mm must be kept between the fan guard and any adjacent surface to ensure unobstructed heat dissipation. Also respect the maximum installation height of 1000 m above sea level and ambient temperature range of +5 °C to +40 °C.

Operating Instructions, Chapter 4.1, p. 10 and Chapter 7.1, p. 16
Electrical
Terminal clearances and torques must be respected

In the terminal box, maintain at least 5.5 mm clearance between bare live parts and to ground at nominal voltage ≤ 690 V. Tighten M4 terminals to 0.8–1.2 Nm and M5 terminals to 1.8–2.5 Nm. Ensure no protruding wire pieces. Supply deviations of ±5 % voltage and ±2 % frequency are permissible without performance reduction.

Operating Instructions, Chapter 7.2, p. 18
Process Limits
Self-priming requires ≥900 mbar abs. inlet vacuum at start

For self-priming operation, a vacuum of at least 900 mbar abs. must be present in the inlet pipe at switch-on, and the liquid level in the feed pipe/reservoir must be at the same level as the center of the unit shaft. During operation, the reservoir level may not drop below approximately 1 m below the shaft center. Pre-throttle on the inlet side if needed.

Operating Instructions, Chapter 8.2, p. 24
Process Limits
Operating-liquid feed pressure must be 1 bar above inlet pressure

When operating with operating-liquid feed, set the pre-pressure pA in the feed pipe to approximately 1 bar above the inlet pressure pB. The nominal operating-liquid flow rate for the 2BV7061 is 0.23 m³/h with dry air extraction and water at 15 °C. Use 0.55 l for priming fill before commissioning.

Operating Instructions, Chapter 8.3, p. 25 and Chapter 4.3, p. 11
Maintenance
Consult service for installation above 1000 m altitude

The maximum installation height is 1000 m above sea level. Operating at higher altitudes requires consultation with the service department because motor cooling and performance may be affected. This is not a user-adjustable limit.

Operating Instructions, Chapter 7.1, p. 16

Selection & Integration Q&A

When should I choose the 2BV7061 instead of the 2BV7060 or 2BV7070/7071?

Choose the 2BV7061 when you need a 2.5 kW liquid-ring machine with a maximum compressor discharge pressure of 1.9 bar abs. at p1 = 1 bar abs. The 2BV7060 offers higher pressure (2.4 bar abs.) but lower motor power (1.60 kW); the 2BV7070/7071 have higher pumping speeds and higher compressor discharge pressures (3.0/2.5 and 3.5/2.2 bar abs.), but are larger and more powerful. The 2BV7061 is also the only variant -1 in the series.

What are the requirements for the operating-liquid supply system when integrating the 2BV7061?

For operation with operating-liquid feed, set the pre-pressure in the feed pipe to approximately 1 bar above the inlet pressure. Provide a nominal flow of 0.23 m³/h (water at 15 °C, dry air). For self-priming mode, ensure the reservoir level is at the shaft center at start and never drops more than 1 m below it during operation.

What mounting and environmental limits apply to the 2BV7061?

Install on a surface that limits vibration velocity to 4.5 mm/s, using 4 x M8-6.8 bolts. Keep at least 34 mm clearance from the fan guard. Ambient temperature must be +5 °C to +40 °C, and installation height must not exceed 1000 m above sea level. The pumped gas temperature must not exceed 80 °C.

What maintenance and service items are required, and what is not included in the base delivery?

The base delivery does not include operating liquid, piping, or electrical cables. The manual provides a fault table for troubleshooting. Regular checks should include operating-liquid flow and temperature, vibration levels, and terminal tightness. No specific maintenance intervals are given in the provided facts; consult the service department for altitude >1000 m or other deviations.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — L-BV7 2BV7061 IE3 compressor (EN)
Datasheet ·272,6 КБ ·3 pp.
View PDF
PDF
Operating Instructions — (EN)
Manual ·3,5 МБ ·44 pp.
View PDF