Elmo Rietschle 2BV7071
Elmo Rietschle 2BV7071 — Liquid Ring Vacuum Pumps with Motor power 7.3 kW.
The 2BV7071 is a liquid-ring vacuum pump/compressor from the L-BV7N series, built as a close-coupled pump-motor unit with a 6.3 kW (50 Hz) / 7.3 kW (60 Hz) IE3 motor and IP55 protection. It is the largest frame in the series (2BV707 size), distinguished by a maximum permissible pressure of 8 bar abs. and a compressor duty limit of 3.5 bar abs. discharge at 1 bar abs. inlet (50 Hz). It is used for vacuum generation or pressure duty where a liquid ring provides robust handling of wet or contaminated gases.
Elmo Rietschle L-BV7 Series — Model Comparison & Selection
Full specifications
| Max inlet pressure | 8 bar abs. |
| Motor power | 6.3 kW (50 Hz) 60 Hz: 7.3 kW |
| Operating principle | Liquid ring |
| Weight | 55 kg (2BV7071-2) 2BV7071-3: 68 kg |
| Power supply | AC (3~ 50/60 Hz) |
| Noise level | 76 dB(A) (50/60 Hz) |
| Operating temperature | +80 °C |
| Protection rating | IP55 |
| Ambient temperature limit | +40 °C |
Description
Construction and series positioning
- The 2BV7071 is a single-stage liquid-ring machine with an eccentrically arranged impeller in a cylindrical housing; the operating liquid forms a rotating ring that draws gas through the inlet port, compresses it and discharges it through the discharge port.
- Within the L-BV7N series it is the largest frame: the 2BV707 size uses 4 x M10-6.8 feet bolting and requires 53 mm clearance from the fan guard, versus 4 x M8 and 34 mm for the 2BV706 frame (2BV7060/2BV7061).
- Two weight variants exist: 2BV7071-2 at 55 kg and 2BV7071-3 at 68 kg. The datasheet also lists cast iron (RAL 9006) and stainless steel (CrNi casing/port plate, bronze impeller, cast iron lantern) executions, voltage variants K08-1B, K08-6B and Q08-7B, and ATEX category 2G versions.
- Compared with siblings, the 2BV7071 offers the highest compressor discharge limit (3.5 bar abs. at 50 Hz, 2.2 bar abs. at 60 Hz) and the highest nominal operating-liquid flow (0.45/0.55 m³/h at 50/60 Hz); the 2BV7070 shares the 8 bar abs. pressure class but has a lower compressor limit (3.0/2.5 bar abs.), while 2BV7060/2BV7061 are limited to about 2 bar abs.
Behavior under load and media limits
- Maximum permissible pressure in the pump-motor unit is 8 bar abs.; in vacuum-pump operation the discharge pressure must not exceed 1.3 bar abs., and when pumped gases are passed on the discharge limit is 1.1 bar abs.
- In compressor operation at inlet pressure p1 = 1 bar abs., maximum discharge pressure is 3.5 bar abs. at 50 Hz and 2.2 bar abs. at 60 Hz — the frequency dependence must be respected when selecting the drive.
- Pumped gas/vapor temperature and operating-liquid temperature are both limited to +80 °C (operating liquid minimum +5 °C, nominal +15 °C); ambient temperature must stay between +5 °C and +40 °C.
- Nominal operating-liquid flow with dry air extraction and water at 15 °C is 0.45 m³/h at 50 Hz and 0.55 m³/h at 60 Hz; priming fill amount is 1.10 l.
Installation, connection and operation
- The unit must be bolted to a supporting surface with 4 x M10-6.8 fasteners, with total vibration velocity not exceeding 4.5 mm/s and installation height no more than 1000 m above sea level.
- Pipe connections on intake and discharge must not be tightened beyond 100 Nm.
- Two operating modes are defined: self-priming operation (requires at least 900 mbar abs. vacuum in the inlet pipe at switch-on and a liquid level in the feed pipe/reservoir at the shaft centerline; reservoir level may not drop more than approx. 1 m below shaft center during running) and operation with operating-liquid feed (feed pre-pressure pA approx. 1 bar above inlet pressure pB).
- Electrical connection is to a 3~ 50/60 Hz AC supply; terminal plate screws must be tightened to 0.8–1.2 Nm (M4) or 1.8–2.5 Nm (M5), with at least 5.5 mm clearance between bare live parts and to ground. Supply deviations of ±5 % voltage and ±2 % frequency are permissible without performance reduction.
Integration & Operating Notes
In vacuum-pump operation the maximum discharge pressure is 1.3 bar abs.; when pumped gases are passed on, the limit drops to 1.1 bar abs. Downstream equipment and piping must be sized so back-pressure cannot exceed these values, otherwise the unit may be damaged or the process invalidated.
The 2BV707 frame uses 4 x M10-6.8 feet fasteners. The foundation and piping must ensure total vibration velocity does not exceed 4.5 mm/s; excessive vibration shortens service life and can invalidate operation. Also maintain 53 mm clearance from the fan guard to any adjacent surface for heat dissipation.
The tightening torque for pipe connections on the intake and discharge ports must not exceed 100 Nm. Over-tightening can damage the port plate or casing, particularly on the stainless steel execution; use appropriate sealing methods and support the piping independently where necessary.
The installation location must remain within +5 °C to +40 °C ambient. Installation height is limited to 1000 m above sea level; higher altitudes require consultation with service because cooling and motor performance change. Pumped gas and operating-liquid temperatures are each limited to +80 °C, with operating liquid minimum +5 °C and nominal +15 °C.
Selection & Integration Q&A
Pick the 2BV7071 when you need the highest compressor discharge pressure in the series (3.5 bar abs. at 50 Hz) and the highest operating-liquid flow (0.45/0.55 m³/h). The 2BV7070 shares the 8 bar abs. pressure class but is limited to 3.0/2.5 bar abs. compressor discharge; the 2BV7060/2BV7061 are limited to about 2 bar abs. and suit lower-pressure duty.
The motor is a 3~ 50/60 Hz AC machine rated 6.3 kW at 50 Hz and 7.3 kW at 60 Hz, IP55. The supply must stay within ±5 % voltage and ±2 % frequency of the rating plate without performance loss. Terminal screws require 0.8–1.2 Nm (M4) or 1.8–2.5 Nm (M5), with at least 5.5 mm clearance between bare live parts and to ground.
Provide operating liquid at 0.45 m³/h (50 Hz) or 0.55 m³/h (60 Hz) with water at 15 °C, and prime with 1.10 l before commissioning. In self-priming mode the inlet must reach 900 mbar abs. at switch-on with reservoir level at shaft centerline. The base unit does not include the operating-liquid feed system, reservoir, piping or electrical cables; these must be sourced separately.