Elmo Rietschle V-VCS 100
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle V-VCS 100

Elmo Rietschle V-VCS 100 — Central Industrial & Medical Vacuum Systems.

The V-VCS 100 is a single-stage, oil-flooded rotary vane vacuum pump with integrated mesh filter, oil mist separator and non-return valve, rated at 100 m³/h at 50 Hz. Within the V-VCS series it is the standard model, distinguished from the V-VCX variant by lower water-vapour tolerance and from smaller/larger siblings by its 0.5–500 mbar(abs) continuous intake range. It serves as the vacuum source in central industrial vacuum systems, evacuating closed volumes up to 2% of its nominal capacity.

Elmo Rietschle V-VCS Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBPumping speed, m³/hUltimate pressure, mbarWeight, kgCurrent, A
V-VCS 100 Current ——————
V-VCS 1100 258126180742.9–74.5
V-VCS 200 ——————
V-VCS 40 1.163480.5392.34–4.07
V-VCS 400 9734000.535710.5–18.1

Full specifications

Description

Construction and series positioning

Behaviour under load and in different media

Installation, connection and operation

Integration & Operating Notes

Process Limits
Intake pressure must stay within 0.5–500 mbar(abs)

Operating below 0.5 mbar(abs) or above 500 mbar(abs) can cause oil leakage through the outlet and invalidate pump performance. For continuous duty above 100 mbar(abs), specify the next higher motor output to prevent overheating.

Operating Instructions BA 237-EN, Chapter 4.4, page 16
Process Limits
Closed volume to evacuate ≤2% of nominal capacity

When evacuating a closed system, the connected volume must not exceed 2% of the pump's nominal pumping capacity (100 m³/h at 50 Hz). Exceeding this ratio leads to excessive evacuation time and potential oil carry-over.

Operating Instructions BA 237-EN, Chapter 4.4, page 16
Mounting
Horizontal installation with ≤1° inclination in all directions

The machine must be installed on a plane, even floor and secured against tipping or falling. Greater inclination can impair oil distribution and cause premature wear or oil leakage.

Operating Instructions BA 237-EN, Chapter 5.2, page 17
Mounting
Maintain 30 cm cooling clearance and 40 cm maintenance access

Cooling air inlets and outlets must be at least 30 cm from adjacent walls to prevent recirculation of hot exhaust air. At least 40 cm space around the machine is required for access to the suction flange, oil filling point, oil sight glass, oil drain, gas ballast and de-oiler housing.

Operating Instructions BA 237-EN, Chapters 5.1 and 5.2, pages 17
Electrical
Mains voltage and frequency deviations limited to ±5% and ±2%

The motor is designed per DIN EN 60034 with IP 55 protection and insulation class F. Supply quality outside ±5% voltage or ±2% frequency deviation can cause loss of power or motor damage; verify the motor data plate matches the mains supply.

Operating Instructions BA 237-EN, Chapter 5.5, page 19
Electrical
Motor protection switch must tolerate start-up current

Select a motor protection switch with overload-dependent delayed switch-off (version with short-circuit and overload trigger per IEC 60947-4-1) to accommodate short-term excess current at start-up and avoid nuisance tripping.

Operating Instructions BA 237-EN, Chapter 8.1, page 33
Process Limits
Exhaust back pressure must not exceed +100 mbar

Exhaust piping and any connected equipment must not create back pressure exceeding +100 mbar. No filter may be installed on the exhaust side, as it would increase back pressure and risk pump damage.

Operating Instructions BA 237-EN, Chapter 5.3, page 18
Process Limits
Parallel pumps require external non-return valves

When operating multiple pumps in parallel, install an external non-return valve in the suction line upstream of each pump. This prevents a switched-off pump from being damaged by the suction capacity of operating pumps.

Operating Instructions BA 237-EN, Chapter 5.3, page 18
Process Limits
Vent suction line for standstill >2 minutes

For standstill times longer than two minutes, vent the connected suction line to atmospheric pressure (e.g. via a ball valve) to avoid possible damage to the machine. The integrated non-return valve only maintains vacuum for approximately 2 minutes after stop.

Operating Instructions BA 237-EN, Chapter 5.3, page 18
Maintenance
Use only ISO VG 100 lubricating oil

Lubricating oil viscosity must comply with ISO VG 100 as per DIN ISO 3448. Incorrect viscosity can cause overheating, insufficient lubrication or poor vacuum performance. For storage longer than 3 months, use preservation oil instead of operating oil.

Operating Instructions BA 237-EN, Chapter 7.6, page 26
Environment
Ambient and inlet temperature must stay within 12–40 °C

Operation outside this range requires consultation with the manufacturer. Ensure installation room ventilation and temperature control. Above 1000 m altitude, output reduction is noticeable; contact manufacturer for high-altitude installations.

Operating Instructions BA 237-EN, Chapter 2.4, page 8 and Chapter 5.2, page 17
Maintenance
Storage limited to 6 months with preservation oil

Store dust-free, dry, vibration-free and protected from sun radiation at -10 to +60 °C and max 80% relative humidity. For long-term storage (>3 months), use preservation oil; do not store for more than 6 months.

Operating Instructions BA 237-EN, Chapter 3.2.1, page 13

Selection & Integration Q&A

When should I choose the V-VCS 100 instead of a V-VCX 100 or a larger V-VCS 200?

Choose V-VCS 100 for standard vacuum duty with intake pressures 0.5–500 mbar(abs) and low water-vapour load. Select V-VCX 100 if the process carries higher water vapour (increased gas ballast, epoxy slide gates). Choose V-VCS 200 when nominal capacity above 100 m³/h at 50 Hz is required.

What are the requirements for the suction line and exhaust piping when integrating the V-VCS 100?

Suction line must be vented to atmosphere for standstill >2 min (e.g. ball valve). For parallel pumps, install an external non-return valve upstream of each pump. Exhaust back pressure must not exceed +100 mbar; no filter may be installed on the exhaust side.

What mounting and environmental limits apply to the V-VCS 100 installation?

Install horizontally with ≤1° inclination on a level floor, secured against tipping. Keep 30 cm clearance around cooling air inlets/outlets and 40 cm access space for maintenance. Ambient and inlet temperature must be 12–40 °C; above 1000 m altitude output reduction occurs.

What maintenance items and consumables are required for the V-VCS 100, and what is not included in base delivery?

Use only ISO VG 100 lubricating oil per DIN ISO 3448; for storage >3 months use preservation oil. Maintenance includes oil changes, oil separator elements, fan, motor and coupling checks per the maintenance table. External non-return valves, vent valves and motor protection switch are not included and must be provided by the installer.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — VCS 100 vacuum pump (BA 237-EN, ed. 1.1 05/07/2022, EN)
Manual ·2,7 МБ ·38 pp.
View PDF