Elmo Rietschle VCD 400
Elmo Rietschle VCD 400 — Central Industrial & Medical Vacuum Systems with Motor power 9 kW, Noise level 75 dB, Pumping speed 480 m³/h.
The VCD 400 is an oil-flooded rotary vane vacuum pump in the V-VC series, configured with an 11 kW IE3 motor for 50 Hz operation and delivering 400 m³/h nominal suction capacity. It achieves an ultimate partial pressure of 0.1 mbar (0.5 mbar with gas ballast) and is positioned as the mid-size unit between the VCD 202 and larger V-VC 500/700/900 siblings. Its primary role is continuous duty in central industrial vacuum systems where high pumping speed at fine vacuum is required.
Elmo Rietschle VCD Series — Model Comparison & Selection
Full specifications
| Motor power | 9.0 kW (50 Hz) |
| Noise level | 73 dB (50 Hz) 60 Hz: 75 dB |
| Pumping speed | 12 l 50 Hz: 400 m³/hour · 60 Hz: 480 m³/hour |
| Ultimate pressure | 0.1 mbar with gas ballast: 0.5 mbar |
| Rotational speed | 975 rpm (50 Hz) |
| Series mfr | V-VC 400 | 500 | 700 | 900 |
| Nominal suction capacity mfr | 400 m3/h (50 Hz) |
| Nominal suction capacity mfr | 480 m3/h (60 Hz) |
| Ultimate vacuum (with gas ballast) mfr | 0.5 (10) mbar |
| Motor version mfr | UN IE3 (50 Hz) |
| Motor diameter (Øw*) mfr | 347 mm (50 Hz) |
| Motor speed mfr | 1170 min-1 (60 Hz) |
| Motor notes mfr | UR, CSA, EAC |
| Motor diameter (Øw*) mfr | 366 mm (60 Hz) |
| Vacuum connection R mfr | G 3 |
| Exhaust R1 mfr | Rp 3 |
| Nennsaugvermögen / Nominal suction capacity mfr | 400 m3/h (50 Hz) |
| Nennsaugvermögen / Nominal suction capacity mfr | 480 m3/h (60 Hz) |
| Enddruck (mit Gasballast) / Ultimate vacuum (with gas ballast) mfr | 0.5 (10) mbar |
| Motor version mfr | HM IE3 |
| Diameter Øw* mfr | 347 mm |
| a1 mfr | 864 mm |
| a2 mfr | 787 mm |
| b mfr | 931 mm |
| c mfr | 606 mm |
| d mfr | 340 mm |
| e mfr | 415 mm |
| f mfr | 380 mm |
| g mfr | 540 mm |
| h mfr | 330 mm |
| l mfr | 310 mm |
| o mfr | 410 mm |
| p mfr | 515 mm |
| q mfr | 372 mm |
| r mfr | 405 mm |
| øs mfr | M12 |
| t mfr | M 40 x 1,5 |
| u mfr | 40 mm |
| R (Vakuum-connection / Vacuum connection) mfr | G 3 |
| R1 mfr | Rp 3 |
| Weight | 357 kg |
| Height | 606 mm |
| Length | 1390 mm |
| Width | 347 mm |
| max. Weight without motor mfr | 357 kg |
| Motor weight mfr | 114 kg (50 Hz) |
| Motor total length (a*) mfr | 1390 mm (50 Hz) |
| Motor weight mfr | 170 kg (60 Hz) |
| Motor total length (a*) mfr | 1450 mm (60 Hz) |
| Dimension a1 mfr | 864 mm |
| Dimension a2 mfr | 787 mm |
| Dimension b mfr | 931 mm |
| Dimension c mfr | 606 mm |
| Dimension d mfr | 340 mm |
| Dimension e mfr | 415 mm |
| Dimension f mfr | 380 mm |
| Dimension g mfr | 540 mm |
| Dimension h mfr | 330 mm |
| Dimension l mfr | 310 mm |
| Dimension o mfr | 410 mm |
| Dimension p mfr | 515 mm |
| Dimension q mfr | 372 mm |
| Dimension r mfr | 405 mm |
| Dimension øs mfr | M12 |
| Dimension t mfr | M 50 x 1,5 |
| Dimension u mfr | 40 mm |
| max. weight ohne Motor / max. Weight without motor mfr | 357 kg |
| Motor weight mfr | 114 kg |
| Dimension a1 (alt var) mfr | 864 mm |
| Dimension a2 (alt var) mfr | 787 mm |
| Dimension b (alt var) mfr | 931 mm |
| Dimension R mfr | G 3 |
| Dimension R1 mfr | Rp 3 |
| Current | 18.1 / 10.5 A (50 Hz) |
| Voltage | 400 / 690 V (50 Hz) |
| Motor voltage mfr | 220 / 380 | 440 V ± 10 % (60 Hz) |
| Motor current mfr | 42.8 / 24.8 | 21.4 A (60 Hz) |
| Motors HM IE3 weight (alt var) mfr | 114 kg |
| Inlet connection | M 40 x 1.5 |
| Oil capacity mfr | 12 l |
| Öleinfüllmenge / Oil capacity mfr | 12 l |
| Average noise level mfr | 75 dB(A) (60 Hz) |
| Mittlerer Schalldruckpegel / Average noise level mfr | 73 dB(A) (50 Hz) |
| Mittlerer Schalldruckpegel / Average noise level mfr | 75 dB(A) (60 Hz) |
Description
Construction and series positioning
- Oil-flooded rotary vane principle with a nominal suction capacity of 400 m³/h at 50 Hz (480 m³/h at 60 Hz).
- This VCD 400 modification uses a 9.0 kW UN IE3 motor at 50 Hz (13 kW at 60 Hz) and is positioned as the mid-size unit between the smaller VCD 202 and the larger V-VC 500/700/900 siblings.
- Pump body weight without motor is 357 kg; motor adds 114 kg (50 Hz) or 170 kg (60 Hz), giving a total installed mass of approximately 471–527 kg depending on frequency.
Performance and operating behavior
- Ultimate partial pressure is 0.1 mbar; with gas ballast engaged, ultimate vacuum rises to 0.5 mbar.
- Average noise level is 73 dB(A) at 50 Hz and 75 dB(A) at 60 Hz, reflecting the larger displacement compared with smaller series members.
- Oil capacity is 12 l; the pump is designed for continuous industrial duty, with the gas ballast allowing handling of condensable vapors at the cost of ultimate pressure.
Installation, connection and control
- Motor is a 3-phase UN IE3 unit rated for 400/690 V ±10 % at 50 Hz and 220/380–440 V ±10 % at 60 Hz; current draw is 18.1/10.5 A (50 Hz) and 42.8/24.8/21.4 A (60 Hz) depending on connection.
- Overall dimensions: height c = 606 mm; motor total length is 1390 mm (50 Hz) or 1450 mm (60 Hz) with a diameter of 347 mm (50 Hz) or 366 mm (60 Hz).
- The technical data sheet covers 50/60 Hz variants and notes a water-cooled version is available; the VCD 400 as specified here is the air-cooled standard build with UN IE3 motor.
Integration & Operating Notes
The 50 Hz motor is rated 400/690 V ±10 % and the 60 Hz motor 220/380–440 V ±10 %. Connecting the motor to a supply outside these windows, or to the wrong winding configuration, will cause overheating or loss of torque. Verify the actual plant voltage and the motor nameplate link arrangement before first start.
When the gas ballast is opened to handle condensable vapors, the achievable ultimate vacuum degrades to 0.5 mbar. Do not specify the pump for 0.1 mbar end-vacuum processes while relying on continuous gas ballast operation; either accept the higher pressure or use a cold trap/condenser upstream.
The pump holds 12 l of oil. In industrial vacuum service, oil is degraded by condensable vapors and particulate ingress; the gas ballast helps but does not eliminate oil change needs. Establish an oil sampling routine and replace oil when it darkens or emulsifies. Oil and oil filters are consumables not included in base delivery.
Selection & Integration Q&A
Pick the VCD 400 when your required suction capacity is around 400 m³/h at 50 Hz and ultimate pressure near 0.1 mbar. The VCD 202 is smaller and suits lower flow; the V-VC 500/700/900 are larger frames for higher flows. The VCD 400 is the mid-size compromise with a 9.0 kW IE3 motor.
The 50 Hz UN IE3 motor requires a 3-phase supply matching 400/690 V ±10 % and draws 18.1/10.5 A depending on connection. Provide a motor protection switch or VFD rated for at least 9.0 kW and set overload to the nameplate current for the chosen winding. The 60 Hz variant needs 220/380–440 V and draws up to 42.8 A.
The base pump delivery excludes oil (12 l charge required), inlet filters, exhaust filters, gas ballast valve (if not factory-fitted), and electrical cables. The technical data sheet lists motor variants and a water-cooled option separately; confirm whether the gas ballast and IE3 motor are included in your specific order code.