Nabertherm GW 2200
Nabertherm GW 2200 — Fusing.
The GW 2200 is a 2200-litre wire-heating chamber furnace rated to 900 °C, built with a 2300 × 1200 × 800 mm working chamber and a 3240 × 2030 × 1400 mm outer envelope at 2160 kg. It is the larger of the two GW sizes listed alongside the GW 1660, intended for bulk fusing and heat-treatment batches that exceed the smaller chamber.
Nabertherm GW Series — Model Comparison & Selection
| Model | Chamber volume, L | Weight, kg | Electrical connection | Max temperature, °C |
|---|---|---|---|---|
| GW 2200 Current | 2200 | 2160 | 3-phase | 900 |
| GW 1660 | 1660 | 1780 | 3-phase | 900 |
Full specifications
| Chamber volume | 2200 l |
| Electrical connection | 3-phase |
| Heating mfr | 90 |
| Inner dimensions (W × D × H) mfr | 2300 × 1200 × 800 mm |
| Outer dimensions (W × D × H) mfr | 3240 × 2030 × 1400 mm |
| Weight | 2160 kg |
| Max temperature | 900 °C |
Description
Construction and series position
- Wire-heating chamber furnace in the GW series; the 2200-litre chamber is the larger sibling of the GW 1660 in the available data.
- Working chamber 2300 × 1200 × 800 mm (W × D × H); outer dimensions 3240 × 2030 × 1400 mm; unit weight 2160 kg.
- Electrical connection is 3-phase; maximum working temperature 900 °C.
- The '2200' in the model code is the chamber volume in litres, not an electrical rating.
Behaviour and duty
- No digitized curve points or heating-rate data are available for this model; thermal behaviour must be taken from the factory specification sheet rather than inferred.
- The 900 °C ceiling places this furnace in the fusing / low-temperature heat-treatment band of the category path, not in high-temperature sintering duty.
Control and documentation
- The attached controller digest covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F temperature-uniformity instrumentation types; it does not print model-specific wiring for the GW 2200.
- The remaining attached documents (fiber-optics glass, foundry, dental) describe other product lines and contain no GW 2200 data; they should not be used for this model's integration.
Integration & Operating Notes
At 2160 kg empty and 3240 × 2030 mm footprint, the point and distributed floor loads exceed typical light-industrial slab allowances once a 2200-litre charge is added. Verify structural capacity and keep the 1400 mm height clearance for door swing and service access.
The wire-heating element set and chamber insulation are rated to a 900 °C maximum. Programmed setpoints, over-temperature limits and any fusing recipe must be capped below this value; sustained operation above it risks element and lining damage.
Selection & Integration Q&A
Pick the GW 2200 when the batch needs the 2200-litre, 2300 × 1200 × 800 mm chamber; the GW 1660 is the smaller sibling. Both are 900 °C wire-heating furnaces, so the decision is charge volume and floor space, not temperature class.
A 3-phase power feed sized to the factory connection data, plus a separate controller from the Nabertherm 500 series or equivalent, with thermocouples and any AMS2750F recorder specified as options. The furnace facts give no voltage or current, so confirm these before ordering switchgear.
The matched facts list no included controller, recorder, thermocouples or process-data software; the controller digest presents 500-series controllers and MyNabertherm app functions as options. Budget for these plus the 3-phase supply hardware separately from the furnace itself.