No photo available yet
Nabertherm KTR 4500
Nabertherm KTR 4500 — Heating Cabinets Chamber Ovens.
The KTR 4500 is a 4500-litre electrically heated chamber oven with a 3-phase, 45 kW heating system and a maximum working temperature of 260 °C. Its 1500 × 1500 × 2000 mm chamber makes it the mid-large modification in the KTR series, positioned between the KTR 3100 and KTR 6125. It is intended for batch heat treatment of bulky or high-volume loads where forced-convection uniformity up to 260 °C is required.
Nabertherm KTR Series — Model Comparison & Selection
| Model | Chamber volume, L | Electrical connection | Max temperature, °C |
|---|---|---|---|
| KTR 4500 Current | 4500 | 3-phase | 260 |
| KTR 22500 | 22500 | 3-phase | 260 |
Full specifications
| Chamber volume | 4500 l |
| Electrical connection | 3-phase |
| Heating power in kW1 mfr | 45 |
| Inner dimensions (W × D × H) mfr | 1500 × 1500 × 2000 mm |
| Outer dimensions (W × D × H) mfr | 2445 × 1930 × 2960 mm |
| Max temperature | 260 °C |
Description
Construction and series positioning
- Chamber oven with 4500 l internal volume; inner dimensions 1500 mm W × 1500 mm D × 2000 mm H.
- Outer envelope 2445 mm W × 1930 mm D × 2960 mm H — plan floor space and door swing accordingly.
- Within the KTR family the 4500 sits between the KTR 3100 and KTR 6125; the KTR 1500 and KTR 22500 bracket the range at the small and large ends. Choose the 4500 when the load fits a 1.5 × 1.5 × 2.0 m envelope and 260 °C is sufficient.
- The KTR line is rated to 260 °C; higher-temperature work belongs to the TR (300 °C) or NAT/NA (900 °C) families, not to this model.
Thermal behaviour and media
- Maximum temperature 260 °C; heating power 45 kW from a 3-phase supply.
- No digitized curve points were supplied for this model, so heat-up and uniformity behaviour cannot be quantified here; confirm against the order-specific test record.
- LS variants (safety technology per EN 1539) exist for TR and KTR models; the base KTR 4500 as listed carries no such certification, so solvent-laden or flammable-atmosphere duty must not be assumed.
Control and operation
- The Nabertherm controller series 500 and MyNabertherm app are the standard control platform across the range; process data storage and AMS2750F instrumentation types are controller-level options, not chamber properties.
- No model-specific wiring, ramp or uniformity data is printed in the attached digests; obtain the KTR 4500 wiring diagram and commissioning data with the unit.
Integration & Operating Notes
The KTR 4500 is rated to a maximum of 260 °C. Operation above this limit is outside the model's design and risks damage to the chamber and load; processes requiring up to 300 °C or 900 °C belong to the TR or NAT/NA families instead.
LS variants with safety technology per EN 1539 are offered for TR and KTR models, but the listed KTR 4500 carries no such certification. Do not charge the chamber with solvent-containing or flammable atmospheres unless the LS configuration is explicitly ordered and documented.
Selection & Integration Q&A
Pick the KTR 4500 when the load fits its 1500 × 1500 × 2000 mm chamber and 260 °C is enough. The KTR 3100 suits smaller batches; the KTR 6125 is for larger loads. All share the 260 °C KTR ceiling, so temperature alone does not decide between them — chamber volume does.
The 45 kW heating power is drawn from a 3-phase connection, so the feed, breaker and cable must be sized for full simultaneous heating power rather than average duty. Confirm site short-circuit capacity and provide a dedicated disconnect; the exact voltage and current rating must be taken from the KTR 4500 wiring diagram supplied with the unit.
Controller functions such as process data storage, MyNabertherm app connectivity and AMS2750F instrumentation types belong to the controller series 500 and its options, not to the bare chamber. Specify the controller configuration, recorder and any EN 1539 LS safety package at order time; they are not part of the base KTR 4500.