Nabertherm LH 60/12
Nabertherm LH 60/12 — Furnaces Protective Gas Boxes.
The LH 60/12 is a 60-litre chamber furnace with brick insulation, rated to 1200 °C and powered from a 3-phase supply. Its 400 × 400 × 400 mm chamber distinguishes it from the 30-litre LH 30/12 and the larger 120- and 216-litre siblings in the LH/12 series. It serves as a general-purpose batch furnace for heat treatment under protective gas.
Nabertherm LH Series — Model Comparison & Selection
Full specifications
| Chamber volume | 60 l |
| Chamber volume | 60 l |
| Chamber volume | 60 l |
| Chamber volume | 60 l |
| Chamber volume | 60 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Connected mfr | 8 |
| Inner dimensions (W × D × H) mfr | 400 × 400 × 400 mm |
| Outer dimensions (W × D × H) mfr | 790 × 1180 × 1370 mm |
| Weight | 300 kg |
| Weight | 300 kg |
| Weight | 300 kg |
| Weight | 300 kg |
| Weight | 300 kg |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
Description
Construction and series positioning
- The LH 60/12 is the mid-small member of the LH/12 brick-insulated chamber furnace family, sitting between the LH 30/12 and the LH 120/12 and LH 216/12.
- Chamber volume is 60 l with internal dimensions of 400 × 400 × 400 mm; external envelope is 790 × 1180 × 1370 mm and unit weight is 300 kg.
- Maximum chamber temperature is 1200 °C. The sibling LF 60/14 is the 1400 °C fiber-insulated alternative for higher-temperature duty.
- Electrical connection is 3-phase; the factory sheet lists a connected value of 8 without a unit, so the exact connected load should be confirmed against the nameplate before sizing the supply.
Thermal behaviour
- No digitized heating or cooling curves were supplied for this model, so no heat-up rate or uniformity figure can be stated here.
- The 1200 °C ceiling and brick insulation define the working range; operation above the rated maximum is outside the model's specification.
Control and documentation
- The attached controller digest covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but it prints no furnace-specific settings for the LH 60/12.
- The remaining attached documents (fiber-optics glass, foundry, dental) cover other product lines and contain no LH 60/12 installation or operating data; the model-specific manual should be used for wiring, commissioning and maintenance.
Integration & Operating Notes
The LH 60/12 is rated to a maximum chamber temperature of 1200 °C. Setpoint and over-temperature limits in the controller must be configured so that the brick insulation and heating elements are never driven above this value, which would shorten element and lining life.
Selection & Integration Q&A
Pick the LH 60/12 when a 400 × 400 × 400 mm, 60-litre chamber at up to 1200 °C is enough. Step down to the LH 30/12 for smaller batches, up to the LH 120/12 or LH 216/12 for larger loads, or to the LF 60/14 if 1400 °C is required.
The unit is 3-phase, but the factory sheet lists a connected value of 8 without a unit. Read the nameplate for the actual kW and full-load current, then size the feeder, fuses and isolator to that figure; do not size from the catalog number alone.
The verified facts list no included accessories, controller model or recorder. Controller options, process-data storage and AMS2750F instrumentation are covered in the separate controller digest, so the controller, recorder and any gas fittings should be confirmed against the order.