No photo available yet
Nabertherm LH 120/12
Nabertherm LH 120/12 — Furnaces Protective Gas Boxes.
The LH 120/12 is a 120-litre chamber furnace with brick insulation, rated to 1200 °C and powered from a 3-phase supply. Its 500 × 500 × 500 mm chamber distinguishes it from the smaller LH 30/12 and the larger LH 216/12 within the LH series. It serves as a general-purpose batch furnace for heat-treatment and protective-gas box processes.
Nabertherm LH Series — Model Comparison & Selection
Full specifications
| Chamber volume | 120 l |
| Chamber volume | 120 l |
| Chamber volume | 120 l |
| Chamber volume | 120 l |
| Chamber volume | 120 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Connected mfr | 12 |
| Inner dimensions (W × D × H) mfr | 500 × 500 × 500 mm |
| Outer dimensions (W × D × H) mfr | 890 × 1180 × 1470 mm |
| Weight | 410 kg |
| Weight | 410 kg |
| Weight | 410 kg |
| Weight | 410 kg |
| Weight | 410 kg |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
Description
Construction and series positioning
- Chamber furnace with brick insulation, 120 L working volume, inner chamber 500 × 500 × 500 mm (W × D × H).
- Outer dimensions 890 × 1180 × 1470 mm; unit weight 410 kg.
- Within the LH 1200 °C series, this model sits between the 30-litre LH 30/12 and the 216-litre LH 216/12; the 1400 °C siblings (LF 60/14, LH 30/14) use a different insulation/temperature class and are not interchangeable for 1200 °C duty.
- Electrical connection is 3-phase; the factory sheet lists a connected value of 12 without a unit, so the exact connected load cannot be stated from the verified data.
Thermal behaviour
- Maximum temperature 1200 °C. No digitized heating or cooling curves were supplied for this model, so no heat-up rate or uniformity figure is asserted here.
- The 500 mm cubic chamber gives a compact, roughly equidimensional load space; the brick lining is the standard insulation for this 1200 °C class.
Control and documentation
- The attached controller documentation covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types; it does not print model-specific wiring for the LH 120/12.
- The other attached brochures (fiber-optics glass, foundry, dental) describe other product lines and contain no LH 120/12 data; they should not be used to specify this furnace.
Integration & Operating Notes
The model is rated to a maximum of 1200 °C. Operation above this limit risks insulation and element damage; the 1400 °C siblings in the series are separate models and their capability does not transfer to the LH 120/12.
Selection & Integration Q&A
Pick the LH 120/12 when a 120 L, 500 × 500 × 500 mm chamber at 1200 °C fits the batch. The LH 30/12 is for small loads; the LH 216/12 for larger batches. The 1400 °C models (LF 60/14, LH 30/14) are a different temperature class.
The furnace is a 3-phase unit, but the source lists a connected value of 12 without a unit. Size the feeder, breaker and protection from the nameplate rating on the delivered unit; do not assume 12 kW from the sheet.
The verified data lists only the furnace itself: no controller, recorder, cables or consumables are confirmed as included. Controller and app functions are covered in separate documentation, so specify the controller and any recorder as separate items.