Nabertherm LHT 03/17 D
Nabertherm LHT 03/17 D — Dental sintering furnaces.
The LHT 03/17 D is a 3-litre, 1-phase dental sintering furnace with a 1650 °C maximum temperature and 75 kg maximum load. It is the larger chamber variant in the LHT ../17 D series, distinguished from the LHT 01/17 D by its 3-litre volume. It is used for sintering zirconia and other dental ceramics where precise high-temperature profiles are required.
Nabertherm LHT Series — Model Comparison & Selection
| Model | Chamber volume, L | Maximum load, kg | Weight, kg | Electrical connection | Max temperature, °C |
|---|---|---|---|---|---|
| LHT 03/17 D Current | 3 | 75 | 38 | 1-phase | 1650 |
| LHT 01/17 D | 1 | 30 | 28 | 1-phase | 1650 |
Full specifications
| Chamber volume | 3 l |
| Chamber volume | 4 l |
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Maximum load | 75 kg |
| Connected mfr | 2.70 |
| Max. heating rate up to 1000 °C mfr | 57 |
| Inner dimensions (W × D × H) mfr | 135 × 135 × 200 mm |
| Outer dimensions (W × D × H) mfr | 412 × 450 mm |
| Heating time mfr | 57 min |
| Weight | 38 kg |
| Weight | 38 kg |
| Max temperature | 1650 °C |
| Max temperature | 1650 °C |
Description
Construction and positioning
- The LHT 03/17 D is a chamber furnace with a 3-litre working volume, inner dimensions of 135 × 135 × 200 mm (W × D × H), and a maximum load of 75 kg.
- It is the larger sibling of the LHT 01/17 D within the LHT ../17 D series; the 03 designates the 3-litre chamber, not a rating.
- The outer dimensions are 412 × 450 mm (W × D), and the unit weighs 38 kg.
- Electrical connection is 1-phase; the connected load is listed as 2.70 (unit not stated in the source).
Thermal behaviour
- Maximum temperature is 1650 °C, suitable for sintering dental zirconia and similar ceramics.
- The maximum heating rate up to 1000 °C is 57 (unit not stated in the source; likely °C/min but not confirmed).
- No digitized curve points are available for this model, so no cooling or controlled-rate behaviour can be asserted beyond the heating-rate figure.
Control and operation
- The dental brochure lists the LHT ../17 D series alongside the D580 controller, indicating that this furnace is typically operated with a dedicated dental sintering controller.
- The controller documentation covers process data storage and temperature uniformity instrumentation, but no model-specific wiring or sequencing details are provided for the LHT 03/17 D.
- No installation or connection specifics (terminal assignments, sensor type, interface protocol) are given in the supplied document digests for this model.
Integration & Operating Notes
The furnace is wired for 1-phase operation and the connected load is listed as 2.70 without a unit in the source. The installing engineer must confirm the actual current draw and supply capacity from the nameplate before commissioning, because the digest does not state whether 2.70 refers to kW or kVA.
The 75 kg maximum load applies to the total charge in the 3-litre chamber. Exceeding it risks damage to the chamber floor or heating elements. Distribute the load evenly and account for the weight of any sintering tray or setter used inside the chamber.
The maximum heating rate up to 1000 °C is 57, with the unit not stated in the source. Program the controller so that the ramp does not exceed this value below 1000 °C; above that temperature no rate is specified, so the controller's default or the ceramic manufacturer's profile should be used.
The dental brochure lists the D580 controller together with the LHT ../17 D series. The controller documentation covers process data storage and temperature uniformity instrumentation, but no model-specific terminal diagram or interface protocol for the LHT 03/17 D is included in the supplied digests.
Selection & Integration Q&A
Choose the LHT 03/17 D when the 3-litre chamber and 75 kg load capacity are needed for larger batches or bigger restorations. The LHT 01/17 D has a smaller chamber; select it only if the workload fits its reduced volume and load limit.
It is a 1-phase furnace with a connected load listed as 2.70 (unit not stated). The dental brochure pairs the LHT ../17 D series with the D580 controller. Confirm the actual current draw from the nameplate and provide a supply rated for the connected load before installing the D580.
No maintenance schedule or consumables list is included in the supplied document digests for this model. The D580 controller is referenced in the dental brochure, but it is not stated whether it is included in base delivery. Sintering trays, setters and thermocouples are not listed as included; confirm the scope of delivery with the order documents.