Nabertherm LHTCT 01/16
Nabertherm LHTCT 01/16 — Dental sintering furnaces.
The LHTCT 01/16 is a 1.5-litre dental sintering furnace with a 110 × 120 × 120 mm chamber, rated to 1550 °C and a 30 kg maximum load. Its 3.5 kW single-phase connection and 30 °C/min heating rate up to 1000 °C distinguish it from the larger LHTCT 03/16 sibling. It is intended for chairside or laboratory sintering of zirconia restorations.
Nabertherm LHTCT Series — Model Comparison & Selection
| Model | Chamber volume, L | Electrical connection | Maximum load, kg | Weight, kg | Max temperature, °C |
|---|---|---|---|---|---|
| LHTCT 01/16 Current | 1.5 | 1-phase | 30 | 20 | 1550 |
| LHTCT 03/16 | 3 | 3-phase3 | 60 | 38 | 1550 |
Full specifications
| Chamber volume | 1.5 l |
| Chamber volume | 1.5 l |
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Maximum load | 30 kg |
| Connectedload4 mfr | 3.5 |
| Max. heating rate up to 1000 °C mfr | 30 |
| Inner dimensions (W × D × H) mfr | 110 × 120 × 120 mm |
| Outer dimensions (W × D × H) mfr | 340 × 335 mm |
| Connected mfr | 3.5 |
| Heating time mfr | 30 min |
| Weight | 20 kg |
| Weight | 20 kg |
| Max temperature | 1550 °C |
| Max temperature | 1550 °C |
Description
Construction and series positioning
- Chamber volume 1.5 l; inner dimensions 110 × 120 × 120 mm (W × D × H); outer dimensions 340 × 335 mm (W × D).
- Maximum load 30 kg; unit weight 20 kg.
- Within the LHTCT ../16 series, this is the smallest chamber variant; the sibling LHTCT 03/16 offers a larger chamber for higher throughput. Choose the 01/16 when bench space and single-batch dental sintering are the priority.
Thermal behaviour
- Maximum temperature 1550 °C.
- Maximum heating rate up to 1000 °C is 30 °C/min; no curve points were supplied, so no cooling or controlled-rate profile data can be stated.
- No atmosphere or vacuum specification is provided in the verified facts; operation is therefore described only by the temperature and load limits above.
Electrical and control
- Electrical connection: 1-phase; connected load 3.5 kW.
- The attached controller document covers the Nabertherm 500 series and MyNabertherm app, but contains no model-specific wiring or terminal data for the LHTCT 01/16; electrical installation details must be taken from the unit's own wiring diagram.
- No interfaces, process-media or compliance specifications were verified for this model.
Integration & Operating Notes
The furnace draws a 3.5 kW connected load on a 1-phase supply. The branch circuit, protective device and supply conductors must be sized for this load before installation; the verified facts do not state the operating voltage or current, so the nameplate and wiring diagram of the actual unit must be consulted.
The maximum load is 30 kg. Exceeding it risks damage to the chamber and invalid sintering results. Because the chamber is only 1.5 l, the 30 kg limit is unlikely to be reached with dental frameworks, but it must be respected if the furnace is used for denser loads.
The maximum heating rate up to 1000 °C is 30 °C/min. Programmed ramps that exceed this rate in the lower temperature range will not be followed by the furnace and may cause the actual profile to deviate from the set curve, affecting sintering results.
Selection & Integration Q&A
Pick the 01/16 for single-batch dental sintering where bench space is limited: 1.5 l chamber, 340 × 335 mm footprint, 20 kg. The LHTCT 03/16 has a larger chamber for higher throughput; choose it when batch size, not space, is the constraint.
The furnace is a 1-phase unit with 3.5 kW connected load. The branch circuit and protective device must be sized for this load. The verified facts do not state voltage or current, so the unit nameplate and wiring diagram must be used for conductor and breaker sizing.
The verified facts contain no maintenance schedule, service intervals, or accessory list for the LHTCT 01/16. The attached controller and dental brochures do not specify consumables or cables for this model; these must be obtained from the unit's operating manual.