Nabertherm LHTCT 03/16
Nabertherm LHTCT 03/16 — Dental sintering furnaces.
The LHTCT 03/16 is a 3-litre, 1550 °C sintering furnace with a 120 × 210 × 120 mm chamber and 60 kg maximum load, part of the LHTCT ../16 series. It is distinguished from the smaller LHTCT 01/16 by its larger chamber volume. It is intended for high-temperature sintering processes in dental laboratories.
Nabertherm LHTCT Series — Model Comparison & Selection
| Model | Chamber volume, L | Electrical connection | Maximum load, kg | Weight, kg | Max temperature, °C |
|---|---|---|---|---|---|
| LHTCT 03/16 Current | 3 | 3-phase3 | 60 | 38 | 1550 |
| LHTCT 01/16 | 1.5 | 1-phase | 30 | 20 | 1550 |
Full specifications
| Chamber volume | 3 l |
| Electrical connection | 3-phase3 |
| Maximum load | 60 kg |
| Connectedload4 mfr | 8.5 |
| Max. heating rate up to 1000 °C mfr | 30 |
| Inner dimensions (W × D × H) mfr | 120 × 210 × 120 mm |
| Outer dimensions (W × D × H) mfr | 415 × 545 mm |
| Weight | 38 kg |
| Max temperature | 1550 °C |
Description
Construction and series positioning
- The LHTCT 03/16 is a chamber furnace with a 3 l working volume and inner dimensions of 120 × 210 × 120 mm (W × D × H).
- Within the LHTCT ../16 series, it sits above the LHTCT 01/16, offering greater chamber capacity for larger batches or components.
- Maximum load is 60 kg, and the furnace itself weighs 38 kg.
Thermal behaviour
- Maximum operating temperature is 1550 °C.
- The maximum heating rate up to 1000 °C is 30 (unit not specified in the source; likely °C/min).
- No digitized curve points are available for this model, so no further dynamic behaviour can be stated.
Electrical and control
- The furnace is designed for a 3-phase electrical connection with a connected load of 8.5 (unit not specified; likely kW).
- Controller and process control details are not provided in the available documents for this specific model; refer to the standard Nabertherm controller series 500 and MyNabertherm app documentation for general capabilities.
Integration & Operating Notes
The connected load is listed as 8.5 without a unit; confirm from the nameplate whether this is kW or kVA and ensure the 3-phase supply and protection devices are sized accordingly. The furnace must be installed by a qualified electrician according to local codes.
Exceeding the maximum load of 60 kg may damage the chamber insulation or heating elements. Operating above 1550 °C can lead to premature failure of the furnace. Always respect the maximum heating rate of 30 up to 1000 °C to avoid thermal shock.
Selection & Integration Q&A
Choose the LHTCT 03/16 when you need a 3-litre chamber for larger batches or components; the LHTCT 01/16 has a smaller chamber (1 litre). Both share the same 1550 °C maximum temperature and 3-phase connection.
No specific maintenance schedule is provided in the available documents. General practice for high-temperature furnaces includes periodic inspection of heating elements and thermocouples, and cleaning of the chamber. Refer to the instruction manual for detailed service intervals.
The available facts do not list any included accessories. Typically, furnaces are supplied without crucibles, shelves, or atmosphere control systems unless specified. Contact the manufacturer for a complete delivery scope.