Nabertherm N 1500/85HA
Nabertherm N 1500/85HA — Forced Convection Furnaces.
The N 1500/85HA is a forced-convection chamber furnace with a 1500-litre chamber (1500 × 1000 × 1000 mm) and a maximum temperature of 850 °C, electrically heated and connected to a 3-phase supply. Its 5040-unit circulation rating and 40-unit heating rating distinguish this HA modification within the 1000-litre-class series, where sibling models NA 1500/45 and NA 4000/45 share the forced-convection architecture but differ in size and temperature class. It is intended for uniform heat treatment of large loads in industrial processes requiring forced air circulation.
Nabertherm Forced Convection Chamber Furnaces from 1000 Liter electrically heated | Nabertherm Series — Model Comparison & Selection
| Model | Chamber volume, L | Max temperature, °C | Electrical connection |
|---|---|---|---|
| N 1500/85HA Current | 1500 | 850 | 3-phase |
| NA 4000/45 | 4000 | 450 | 3-phase |
Full specifications
| Chamber volume | 1500 l |
| Chamber volume | 1500 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Circulation mfr | 5040 |
| Heating mfr | 40 |
| Inner dimensions (W × D × H) mfr | 1500 × 1000 × 1000 mm |
| Outer dimensions (W × D × H) mfr | 2600 × 2200 × 1900 mm |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
Description
Construction and series positioning
- The N 1500/85HA is a forced-convection chamber furnace from Nabertherm's 1000-litre-class series, with a 1500-litre working volume and inner chamber dimensions of 1500 × 1000 × 1000 mm (W × D × H).
- Outer dimensions are 2600 × 2200 × 1900 mm (W × D × H), reflecting the insulation and circulation plenum required for forced-convection operation.
- Within the series, the HA modification is identified by its 850 °C maximum temperature and its circulation/heating ratings (5040 and 40 respectively); sibling models NA 1500/45 and NA 4000/45 belong to the same forced-convection family but are separate size/temperature variants and should not be conflated with this model.
Thermal behaviour and media
- The maximum working temperature is 850 °C, electrically heated via a 3-phase connection.
- Forced circulation is the defining mechanism: the 5040 circulation rating indicates the air-movement capacity that supports temperature uniformity across the 1500-litre chamber.
- No digitized curve points were supplied for this model, so heat-up and load-response behaviour cannot be quantified from the available facts; selection should rely on the stated temperature limit and circulation rating.
Control and operation
- Controller and process-data functions are covered by Nabertherm's standard controller series 500 and MyNabertherm app documentation, which addresses process data storage, temperature uniformity per AMS2750F instrumentation types, and recorder/controller options; these are controller-level capabilities, not model-specific ratings.
- The attached document digests do not contain model-specific installation or connection instructions for the N 1500/85HA; electrical connection is 3-phase as stated in the verified specifications.
Integration & Operating Notes
The furnace is specified for a 3-phase electrical connection. The engineer must confirm that the site distribution provides a 3-phase feed sized for the heating load (heating rating 40) and that protective devices and cable routing are coordinated with the furnace's connection data before installation; single-phase operation is not indicated by the verified facts.
The maximum temperature of 850 °C is the upper process limit for this model. Operating above it risks damage to the heating elements, insulation and circulation components, and invalidates any uniformity assumptions; process recipes must be capped at this value with appropriate controller limits.
Process control and documentation depend on the selected Nabertherm controller (series 500 or MyNabertherm app), which supports process data storage and AMS2750F instrumentation types. The controller and recorder are separate selection items; the base furnace facts do not include a controller model, so the integration engineer must specify it explicitly.
Selection & Integration Q&A
Choose the N 1500/85HA when you need a 1500-litre chamber at up to 850 °C with forced convection. The NA 1500/45 and NA 4000/45 are separate series variants with different size/temperature classes; the verified facts do not give their ratings, so compare their published data before deciding.
A 3-phase electrical feed sized for the heating load is required. A Nabertherm controller (series 500 or MyNabertherm app) must be specified separately for process control and data storage; the base furnace facts do not include a controller, so it is an integration item, not part of the furnace delivery.
The verified facts list no maintenance schedule, service intervals, cables, recorder or controller in the base delivery. Controller/recorder options and any consumables must be ordered separately; service intervals should be confirmed with Nabertherm, as the attached document digests contain no model-specific maintenance data.