Nabertherm N 61/H
Nabertherm N 61/H — Chamber furnaces.
The N 61/H is a 3-phase chamber furnace with a 61-litre chamber (350 × 750 × 250 mm W×D×H) rated to 1280 °C, positioned between the smaller N 41/H and N 7/H in the series. Its 20 kW connected load and 105-minute heating time suit annealing, hardening and brazing processes requiring uniform temperature in a long, shallow workspace.
Nabertherm Chamber Furnaces for Annealing, Hardening and Brazing up to 1280 °C | Nabertherm Series — Model Comparison & Selection
| Model | Chamber volume, L | Electrical connection | Weight, kg | Max temperature, °C |
|---|---|---|---|---|
| N 61/H Current | 61 | 3-phase | 400 | 1280 |
| N 7/H | 9 | 1-phase | 60 | 1280 |
Full specifications
| Chamber volume | 61 l |
| Electrical connection | 3-phase |
| Connected mfr | 20.0 |
| Heating time mfr | 105 min |
| Inner dimensions (W × D × H) mfr | 350 × 750 × 250 mm |
| Outer dimensions (W × D × H) mfr | 1040 × 1430 × 1340 mm |
| Weight | 400 kg |
| Max temperature | 1280 °C |
Description
Construction and series positioning
- The N 61/H is the mid-capacity model of the N 41/H–N 61/H–N 7/H series, with a 61-litre chamber and 400 kg unit weight.
- Chamber geometry is 350 mm wide × 750 mm deep × 250 mm high, giving a long, shallow working volume suited to elongated parts or batch trays.
- Outer dimensions are 1040 × 1430 × 1340 mm (W×D×H); the 3-phase electrical connection and 20 kW connected load distinguish it from smaller single-phase siblings.
Thermal behaviour
- Maximum operating temperature is 1280 °C, covering annealing, hardening and brazing regimes.
- The factory-stated heating time of 105 min characterises the empty-chamber ramp; actual load heating will depend on charge mass and fixturing.
- No digitised curve points are available for this model, so no cooling-rate or uniformity claims are made here.
Control and documentation
- The attached controller digest covers the Nabertherm 500-series controllers and MyNabertherm app, including process-data storage and AMS2750F instrumentation types; it does not specify a controller for this model, so the controller must be confirmed at order.
- Other attached digests (fiber-optics glass, foundry, dental) cover different product lines and provide no N 61/H-specific installation facts.
Integration & Operating Notes
The furnace draws a 20 kW connected load on a 3-phase supply; the site distribution, cable cross-section and protective device must be sized for this load before installation, and the actual voltage/frequency must be confirmed against the nameplate because the verified facts do not state them.
The 1280 °C maximum is the upper process limit for annealing, hardening and brazing; operating above it risks heater and insulation damage, and the actual charge temperature should be verified by the controller rather than inferred from the setpoint.
The controller digest describes 500-series controllers, MyNabertherm app connectivity, process-data storage and AMS2750F instrumentation types, but does not assign a specific controller to the N 61/H; the controller, thermocouple type and any recorder must therefore be specified separately at order.
Selection & Integration Q&A
Pick the N 61/H when the 61-litre, 350 × 750 × 250 mm chamber fits long or tray-loaded batches at up to 1280 °C. The N 41/H and N 7/H are smaller siblings; choose them only if their smaller chambers suit the workload, since the N 61/H's 20 kW 3-phase load is the trade-off for capacity.
The furnace is a 3-phase unit with 20 kW connected load; the site must provide a 3-phase feed sized for that load with matching cable cross-section and protective device. The verified facts do not state voltage or frequency, so confirm the nameplate rating before ordering switchgear.
The verified facts list only the furnace itself; no controller, thermocouple, recorder or process-data software is confirmed as included. The controller digest covers 500-series controllers and MyNabertherm app options, so specify controller, instrumentation type and any recorder explicitly at order.