Nabertherm N 7/H
Nabertherm N 7/H — Chamber furnaces.
The N 7/H is a 9-litre chamber furnace with a 250 × 250 × 140 mm workspace, rated to 1280 °C on a 1-phase supply. It is the smallest model in the Nabertherm N/H series, positioned below the N 41/H and N 61/H for small-batch annealing, hardening and brazing. Its 3.0 kW connected load and 320-minute heating time suit low-throughput laboratory and toolroom duty.
Nabertherm Chamber Furnaces for Annealing, Hardening and Brazing up to 1280 °C | Nabertherm Series — Model Comparison & Selection
| Model | Chamber volume, L | Electrical connection | Weight, kg | Max temperature, °C |
|---|---|---|---|---|
| N 7/H Current | 9 | 1-phase | 60 | 1280 |
| N 61/H | 61 | 3-phase | 400 | 1280 |
Full specifications
| Chamber volume | 7 l |
| Chamber volume | 9 l |
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Connected mfr | 3.0 |
| Heating time mfr | 320 min |
| Inner dimensions (W × D × H) mfr | 250 × 250 × 120 mm |
| Outer dimensions (W × D × H) mfr | 720 × 640 × 510 mm |
| Heating mfr | 3.0 |
| Weight | 60 kg |
| Weight | 60 kg |
| Max temperature | 1280 °C |
| Max temperature | 1280 °C |
Description
Construction and series positioning
- The N 7/H is the smallest chamber furnace in the N/H series, with a 9-litre chamber measuring 250 mm wide × 250 mm deep × 140 mm high. Sibling models N 41/H and N 61/H offer larger chambers for higher batch volumes; the N 7/H is intended for small workpieces, sample trials and low-throughput toolroom work.
- The outer enclosure measures 800 × 650 × 600 mm and the unit weighs 60 kg, so it can be placed on a bench or floor stand without special foundations.
- Heating is electric with a 3.0 kW connected load on a 1-phase supply; the maximum working temperature is 1280 °C.
Thermal behaviour
- No digitized heating or cooling curves were supplied for this model. The only thermal data point is a 320-minute heating time to maximum temperature, which indicates a relatively slow ramp for the small chamber; users needing faster cycles should consider a different model or controller-assisted ramping.
- The 1280 °C ceiling covers annealing, hardening and brazing of small steel and non-ferrous parts; the 140 mm chamber height limits the height of fixtures and stacked loads.
Control and documentation
- The attached controller digest covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but it does not print model-specific wiring or ordering codes. The furnace is therefore configured with a standard Nabertherm controller at order; the exact controller variant must be confirmed against the order documents.
- No certificates, applications or curve points were supplied for this model, so no compliance or process-qualification claims can be made from the available facts.
Integration & Operating Notes
The furnace draws 3.0 kW on a 1-phase connection. The site supply, cable cross-section and protective device must be sized for this load; a dedicated circuit is advisable because the furnace runs continuously during long annealing or brazing cycles. The exact voltage and current are not stated in the supplied facts and must be read from the nameplate.
The maximum working temperature is 1280 °C. Exceeding it risks heater, insulation and thermocouple damage and invalidates any temperature-uniformity assumption. The 320-minute heating time to maximum temperature should be treated as the reference ramp; faster uncontrolled heating is not supported by the supplied data.
The controller digest describes the Nabertherm 500-series controllers and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but it does not list a default controller for the N 7/H. The controller, thermocouple type and any recorder option must therefore be specified on the order and confirmed against the delivery documents.
Selection & Integration Q&A
Pick the N 7/H when the workload fits its 250 × 250 × 140 mm chamber and 9-litre volume, for example small tooling, samples or single small batches. The N 41/H and N 61/H are the larger siblings in the same series and should be selected when batch size or workpiece height exceeds the N 7/H chamber.
The furnace is a 1-phase unit with a 3.0 kW connected load. The site must provide a 1-phase circuit sized for this load with an appropriate protective device; the exact voltage and current are not given in the supplied facts and must be read from the nameplate before installation.
The supplied facts list only the furnace itself; controller variant, thermocouple type, recorder options and the MyNabertherm app connection are described in the controller digest but are not confirmed as base-delivery items for the N 7/H. These must be specified on the order and verified against the delivery documents.